The laser gas analyzer of Sifang Instrument adopts TDLAS cross beam technology, effectively avoiding background gas interference and ensuring measurement accuracy. It has a high explosion-proof rating and a multi-stage filtration system, which can operate stably for a long time under harsh working conditions such as high dust and high corrosion, achieving automatic sampling and remote monitoring. Widely used in key safety and process control points such as coal powder silos, blast furnaces, converters, etc., to assist in safety production and energy efficiency improvement.

Product Name:Laser gas analyzer
Product Model:GasTDL-3110
Product Introduction
Laser gas analyzerDesigned for high dust conditions in the sample gas, it consists of four parts: sampling probe, preprocessing unit, control unit, and gas analysis unit. The system adopts tunable semiconductor laser absorption spectroscopy technology (TDLAS) with a beam design, which can continuously reflect the measured gas concentration in real time, which is conducive to improving gas utilization efficiency, energy conservation and consumption reduction, and ensuring safe production in industrial sites.
Product Features
Explosion proof rating Ex db IIC T6 Gb/Ex tb IIIC T80 ℃ Db, high safety factor.
The probe has automatic blowing function, reliable performance, and long lifespan.
It can automatically complete sampling, blowback, drainage and other operations.
Multi level filtration ensures long-term online operation of the instrument.
Using TDLAS technology, the measured gas is not affected by background gas cross interference.
Remote monitoring can be achieved without the need for manual attendance, reducing maintenance costs.
It has good adaptability in harsh measurement environments such as high temperature, high dust, high moisture, high corrosiveness, and high flow rate.
Technical Specifications
| performance parameters |
| Measure components |
H2S、O2、CO、CO2、CH4*
|
| Measuring principle |
TDLAS |
| test scope |
H2S:0 ~ 100ppm,0 ~ 5000ppm
|
|
O2(0-5)% VOL (customizable to 100%)
|
| CO:(0 ~ 100)%VOL |
|
CO2:(0 ~ 100)%VOL
|
|
CH4:(0 ~ 20)%VOL
|
| precision |
≤±1%F.S. |
| repetitiveness |
≤±1% |
| Span Drift |
≤±1%F.S. |
| resolution |
0.01%VOL |
| working parameters |
| Explosion-proof rating |
Ex db IIC T6 Gb / Ex tb IIIC T80℃ Db |
| ambient temperature |
(-20~ +60)℃ |
| working power supply |
220V AC,50Hz
|
| Working gas |
(0.3-0.8) MPa industrial nitrogen |
| Interface signal |
| communication |
RS485、RS232 |
| output mode |
2-channel 4-20mA output |
| 3-channel relay output |
Application field
① Coal mill outlet and coal powder bin for coal injection process (safety monitoring to prevent explosion)
② After the electric tar catcher of the coke oven process (safety monitoring to prevent explosions)
③ Bag filter outlet for blast furnace process (safety inspection, gas composition and calorific value detection), hot air main (monitoring combustion status, regulating device, optimizing production), hot blast furnace exhaust gas (controlling combustion efficiency), and exhaust chimney (online monitoring of exhaust emissions)
④ Before/after the induced draft fan of the converter process (safety monitoring, gas recovery), after the secondary Wen dust removal (steelmaking control, regulating device, optimized production), before and after the gas cabinet (safety control)
⑤ Heating section and exhaust pipe of heating furnace process (process control to improve production efficiency)