Laboratory desktop multi parameter sewage quality analysis and determination instrument

NegotiableUpdate on 01/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The laboratory desktop multi parameter sewage quality analysis and measurement instrument is a key equipment for sewage treatment process control and discharge supervision. It can quickly and accurately measure dozens of core indicators such as COD, BOD ₅, ammonia nitrogen, total phosphorus, total nitrogen, pH value, suspended solids, chromaticity, and fecal coliform bacteria in water, providing scientific basis for the daily operation, process optimization, and discharge compliance of sewage treatment plants.
Product Details

Laboratory desktop multi parameter sewage quality analysis and determination instrumentIt is a key equipment for sewage treatment process control and discharge supervision, which can quickly and accurately measure dozens of core indicators such as COD, BOD ₅, ammonia nitrogen, total phosphorus, total nitrogen, pH value, suspended solids, chromaticity, and fecal coliform bacteria in water, providing scientific basis for the daily operation, process optimization, and discharge compliance of sewage treatment plants.

实验室台式多参数污水水质分析测定仪器

According to the 2024 report from the ecological environment unit, about 17% of sewage treatment plants in China have been punished for exceeding the effluent quality standards, with COD, ammonia nitrogen, and total phosphorus accounting for over 65% of the total. The traditional single parameter detection method is time-consuming, consumes large amounts of reagents, and has high human error. The ERUN-ST series sewage treatment plant laboratory desktop multi parameter water quality analysis and determination instrument integrates spectrophotometry, electrochemical method, and mercury free pressure difference BOD determination technology. A single test can complete more than 8 core parameters within 30 minutes, with measurement error controlled within ± 1.0%, significantly improving laboratory efficiency and data reliability.


Desktop multi parameter water quality analysis and testing instrument for sewage plant laboratory. Product features:

Simultaneous measurement of multiple parameters

Multiple indicators such as pH, conductivity, dissolved oxygen, turbidity, temperature, and ion concentration can be measured at once without the need to use multiple devices separately. Modern multi parameter water quality analyzers often support simultaneous monitoring of 6-12 or even more parameters.

High accuracy and stability

Compared to simple on-site instruments, desktop instruments are more suitable for laboratory environments, with stable measurement and good repeatability. They are suitable for scenarios with strict requirements such as sewage effluent quality testing, discharge compliance, and environmental monitoring.

Convenient data storage and management

Many instruments support data storage, export, and analysis, facilitating the generation of reports, tracking of water quality trends, long-term recording, and data management.

Wide applicability, compatible with multiple water quality types

Whether it's urban sewage, industrial wastewater, surface water, groundwater, or recycled water, this instrument can be used for comprehensive testing; Suitable for sewage plant laboratories, environmental testing institutions, scientific research laboratories, water quality monitoring stations, etc.


Technical parameters of desktop multi parameter water quality analysis and determination instrument in sewage plant laboratory:

serial number measurement items Measurement range unit maximum error
1 COD (low range chromium method) 5-200 or 5-150 mg/L 5%
COD (High Range Chromium Method) 200-2000 or 150-2000 mg/L 5%
2 Ammonia nitrogen (low range) 0.02-5.00 mg/L 3%(F.S)
Ammonia nitrogen (high range) 5.00-25.00 mg/L 3%(F.S)
3 Total phosphorus (low range) 0.02-2.00 mg/L 5%(F.S)
Total phosphorus (high range) 2.00-10.00 mg/L 5%(F.S)
4 Total nitrogen (low range) 0.10-10 mg/L 5%(F.S)
Total nitrogen (high range) 10-100 mg/L 5%(F.S)
5 Anionic surfactant 0.01-1.0 mg/L 5%(F.S)
6 Chromaticity (low range) 5-50 PCU 3%(F.S)
Chromaticity (high range) 50-500 PCU 3%(F.S)
7 suspended solids 5-1000 mg/L ≤2%(F.S)
8 PH (colorimetric method) 5.00-8.00 PH 0.1±0.1
PH (electrode method) 0.00-14.00 PH ±0.1
9 Animal and vegetable oils/petroleum products 0-900.00 mg/L RSD<0.6%
10 Fecal coliforms count —— CFU/mL ——
11 Biochemical Oxygen Demand BOD5 0-4000 mg/L ±8%



Typical applications of desktop multi parameter water quality analysis and determination instrument in sewage plant laboratory:

1Sewage treatment plant inlet/outlet water testing

Perform pH, dissolved oxygen, turbidity, ion concentration and other tests on the inlet and outlet water to determine whether the treatment effect meets the standard.

▲ Support water quality monitoring at discharge outlets to ensure compliance with national or local discharge standards.

2Environmental monitoring and river and lake water quality testing

▲ Used for detecting surface water, river channels, lakes, and groundwater samples, monitoring environmental changes, pollutant concentrations, and ecological water quality safety.

▲ It is possible to establish a long-term water quality database to assist environmental protection departments or research institutions in analyzing pollution trends.

3Industrial wastewater and recycled water detection

Before leaving the factory, various indicators of industrial plant wastewater or recycled water are tested to ensure compliance with the water quality requirements for discharge or reuse.

Monitor multiple water quality parameters in the recycled water treatment system to ensure safe and stable use of circulating water.

4Research and Laboratory Analysis

▲ Used in universities, research institutions, and water quality research institutions for water sample analysis, environmental research, pollution tracing research, and ecological monitoring sample testing.

▲ Standardized laboratory testing to meet the requirements of scientific research for data accuracy, repeatability, and comparability.


Laboratory desktop multi parameter sewage quality analysis and determination instrumentIt is an important instrument in the current water treatment and environmental protection industries. It provides efficient, reliable, and professional water quality analysis solutions for various application scenarios such as wastewater treatment plant effluent monitoring, environmental water quality testing, industrial wastewater compliance, scientific research, water treatment optimization, etc. through single measurement, multi parameter detection, data-driven management, compact structure, and stable operation. For water treatment plants, environmental protection agencies, research institutions, and water plant managers, such instruments are important investments to enhance water quality management capabilities, meet standard compliance, and ensure water resource safety.