Fixed chloroacetyl gas online monitoring and alarm detector

NegotiableUpdate on 01/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Acetyl chloride is a colorless to pale yellow liquid with a strong pungent odor and is highly volatile at room temperature. Its vapor not only has strong corrosiveness to the eyes, skin, and respiratory tract, but also belongs to flammable and explosive gases. Therefore, manual inspection alone is far from enough, and fixed online monitoring equipment must be deployed. The fixed online monitoring and alarm detector for chloroacetyl gas continuously monitors the concentration of C ₂ H ∝ ClO vapor in the air through high-precision ECD electrochemical or PID sensors, which can meet the monitoring and safety alarm needs of chloroacetyl gas leakage in places such as medicine, electroplating, and chemical industry.
Product Details

Acetyl chloride is a colorless to pale yellow liquid with a strong pungent odor and is highly volatile at room temperature. Its vapor not only has strong corrosiveness to the eyes, skin, and respiratory tract, but also belongs to flammable and explosive gases. Therefore, manual inspection alone is far from enough, and fixed online monitoring equipment must be deployed.Fixed chloroacetyl gas online monitoring and alarm detectorContinuous monitoring of the concentration of C ₂ H ∝ ClO vapor in the air through high-precision ECD electrochemical or PID sensors can meet the monitoring and safety alarm requirements for chloroacetyl gas leaks in places such as medicine, electroplating, and chemical industry.

固定式氯乙酰气体在线监测报警探测器

Acetyl chloride (chloroacetyl) is a colorless fuming liquid with a boiling point of only 51 ℃. It undergoes severe hydrolysis to produce HCL and acetic acid when exposed to water or humid air, and has a strong corrosive and irritating odor. According to the Occupational Exposure Limits for Hazardous Factors in the Workplace Part 1: Chemical Hazardous Factors (GBZ 2.1-2019), the time weighted average allowable concentration (PC-TWA) of acetyl chloride in the workplace air is 0.5 mg/m ³, and the short-term exposure allowable concentration (PC-STEL) is 1.5 mg/m ³. Once leaked, low concentrations can cause respiratory burns and skin irritation, while high concentrations may lead to pulmonary edema and even endanger life. For scenarios where acetyl chloride is used in chemical synthesis, pharmaceutical intermediate production, pesticide manufacturing, etc., a fixed online detection and alarm system that can "watch around the clock and shout when it exceeds the standard" is a must-have.


Taking the ERU-PG51SACL fixed online acetyl chloride (chloroacetyl) gas detection alarm of Yingrun Group as an example, its sensor is specifically optimized for acetyl chloride gas. When acetyl chloride gas in the environment diffuses into the sensor, specific chemical reactions or changes in conductivity occur, resulting in an electrical signal proportional to the gas concentration. The signal is analyzed by a built-in high-precision amplification and data processing circuit, and converted into concentration values in real-time (usually in ppm or mg/m ³), which are displayed on the on-site LCD screen or remote monitoring system.


Fixed online acetyl chloride (chloroacetyl) gas detection alarm product features:

Anti reverse connection/overvoltage/unstable power supply protection

Prevent damage caused by misconnection or power fluctuations.

Independent chamber design

Prevent dust/particles from entering the sensor and extend its service life.

Remote control function

Alarm points can be set remotely through infrared or upper computer, alarms can be cleared, and factory settings can be restored.

Multiple installation methods

Pipeline and wall mounted, can be flexibly arranged according to the structure of the factory/pipeline network.


Fixed online acetyl chloride (chloroacetyl) gas detection alarm technical parameters:

Product Model ERUN-PG51SACL
Gas detection Acetyl chloride (chloroacetyl) C2H3ClO
Range resolution C2H3ClO:0-1000ppm、0.1ppm、 Imported high-performance ECD electrochemical principle sensor
or
C2H3ClO:0-100ppm、0.01ppm、 Imported high-precision PID photoionization principle sensor

Other ranges, principles, and resolutions can be customized
detection accuracy ≤± 3% F.S (higher precision can be customized)
Repeatability ≤±2%
Linearity ≤±2%
uncertainty ≤±2%
response time T90 ≤ 20 seconds
recovery time ≤ 30 seconds
signal output Bus based RS485 (Modbus RTU), distributed 4-20mA,
Optional: 0-20mA, 1-5V, 0-5V, 0-10V, wireless transmission, network transmission, SMS alarm.
working method Fixed installation, online detection, diffusion measurement; Optional pipeline, flow, and pump suction measurement.
display mode On site 1.7-inch high-definition color screen display, optional on-site no display, or optional ERUN-PG36E controller for remote display, control, and alarm
alarm method Default 1 channel, optional 2 passive contact (dry node) outputs, three-level alarm, alarm points can be set
On site sound and light alarm
Installation method Pipeline and wall mounted. The working pressure of pipeline type is atmospheric pressure ± 30%. If it exceeds the range, it needs to be depressurized.
Working Voltage 12-30VDC DC, the standard power supply for a single device is 24V, 1A or greater DC stabilized switching power supply
working environment Temperature: -40 ℃~+70 ℃, humidity: ≤ 10~95% RH (conventional) Non condensing occasions
When used in condensation situations, it is necessary to customize or specify the usage environment when ordering
electrical interface 3/4NPT, Optional M20 * 1.5 internal thread, 1/2NPT
connecting cable Choose a three core shielded cable for 4-20mA and a four core cable for RS485. When the distance exceeds 1000 meters, the single wire diameter should be ≥ 1.5mm. The shielding layer should be grounded.
Protection level IP66 waterproof and dustproof rating
Explosion proof type Explosion proof type, Ex db IIC T6 Gb (gas explosion-proof); Ex tb Ⅲ C T80 ℃ Db (dust explosion-proof)
Overall dimensions 210×170×85mm(L×H×W)
Weight 1600g




Typical applications of fixed online acetyl chloride (chloroacetyl) gas detection alarm:

Production of pesticides/plant protection chemicals

Manufacturing or storing reagents containing acyl chlorides and acetylation requires strict requirements for volatile gases.

Synthesis of pharmaceutical and chemical intermediates

Acetyl chloride reaction and synthesis process may release acetyl chloride vapor, which needs to be closely monitored.

Electroplating materials/catalysts/dyes/organic synthesis plants

There is a risk of volatilization or leakage when using chloroacetyl reagents/raw materials.

Storage and transportation warehouse

If the liquid or gas of acetyl chloride evaporates, it needs to be monitored for a long time to prevent exceeding the standard.


ERUN-PG51SACLFixed chloroacetyl gas online monitoring and alarm detectorLock the "0.2ppm toxicity limit+25% LEL explosion limit" into 4-20mA, PID+infrared dual core, IP66 protection, 3-second response, so that the acetyl chloride in the acylation device, storage tank, and sewage tank cannot escape, and the explosion-proof and anti-virus measures are in place at once.