- Phone
-
Address
3rd Floor, Building 79, Daye Territory, Lane 4855, Guangfulin Road, Songjiang District, Shanghai
Shanghai Junyi Instrument Equipment Co., Ltd
3rd Floor, Building 79, Daye Territory, Lane 4855, Guangfulin Road, Songjiang District, Shanghai
LMA200PM Microwave Moisture AnalyzerUsed for analyzing the moisture content of liquid and paste samples, it can detect approximately0.1%to100%The moisture content. When detecting samples with high moisture content, microwave drying is faster than oven drying300Twice. The dry weight and moisture content of the sample are determined byLMA200The built-in analytical weighing system of the moisture meter measures the lost moisture content to calculate.
If the sample has a high moisture content, microwave drying is a faster and more effective method of heating the sample to reduce weight. The sample absorbs moisture through microwave radiation heating. The built-in analytical weighing system measures the weight loss of the sample and determines the endpoint when the sample reaches a constant weight. In addition, the air humidity sensor monitors and analyzes the progress of moisture operation, providing double certainty to ensure reliable results.
LMA200PM Microwave Moisture Analyzer,Product Features
line voltage |
230 V |
readability |
0,1 mg, 0,001 % |
heat source |
Microwave radiation can achieve ultra short measurement time |
Number of storable programs |
300 |
application |
Extremely humid samples, liquid or paste like |
Suggested humidity range |
8 - 100% |
称重能力 |
70 g |
Technical attributes
large range |
70g |
Accuracy of weighing system |
0,0001g |
Average repeatability, initial sample weight approximately1gtime(%) |
+/- 0.05 |
Sample container |
Fiberglass mat, diameter90mm (3.5') |
Measurement result display mode |
%Water,ppmWater,%Volatile compounds,%Dry weight (solid),ppmDry weight,gDry weight,mgLoss after drying,%ratio |
Heating temperature range and setting |
approximately8-100%moisture |
heating unit |
input power1000WThe microwave heater |
Heating power control |
2-100%,increment1% |
Terminal judgment |
Fully automatic, using weighing and moisture sensors; Users define based on weight loss or time:1-50 mg / 1-99second, 0.1-9.9% / 1-99second;Timer Mode: 0.1 - 99.9minute. |
measure time |
approximately40-120(Depending on sample type and moisture content) |
program |
320, stored in memory |
Data printer |
Thermal printer, built-in |
Moisture Analysis Report |
User SettingsGLPreport The report can be printed on * paper using the built-in thermal printer |
Operation Guide |
Menu style, numeric character dialogue box (available in English, French, German, Italian, and Spanish);5A preset function key |
data interface |
1aRS232Interface, used forPCOne Ethernet interface |
Line frequency |
50 Hertz |
wide |
510 x 535 x 304 mm |
High power consumption |
1200 VA |
line voltage |
230 V |
Pan size |
? 90 mm |