LI-710 evapotranspiration measuring instrumentBy using the principle of vorticity covariance measurement, the evapotranspiration ET data of the sample plot can be directly measured.
Due to the complexity of measurement methods, direct measurement of evapotranspiration ET has not been widely used. The indirect measurement method relies on estimates based on crop coefficients and reference/potential evapotranspiration ETo, which can lead to deviations in the quantification of evapotranspiration ET.
LI-710 evapotranspiration measuring instrumentIt can directly measure the actual evapotranspiration ET of the sample plot without the need for crop coefficients. It is suitable for any relatively flat artificial or natural ecosystem with a uniform underlying surface.
|
Main Features Based on the principle of vorticity covariance flux measurement, the measurement results are reliable ● By using direct measurement instead of indirect estimation, the ET number has been increased Accuracy of data ● The connection, operation, and maintenance are very simple ● Research grade data accuracy |
Application field ● Precision irrigation management ● Regional water resources assessment/management ● Monitoring of ecosystem drought ● Ground validation of remote sensing data ● Quantitative analysis of ecological hydrological processes ● Meteorological data supplement |
|
|
Research grade precision | ||
|
LI-710、 Traditional Vorticity Covariance System and Penman MonteithCompare the estimated ET. The evapotranspiration ET measured by LI-710 is highly consistent with the measurement results of the traditional vorticity covariance system.
|
LI-710 applies the vorticity covariance method to measure wind speed and water vapor concentration in the vertical direction at a frequency of 10Hz, and provides processed ET data every 30 minutes.
|
|
instrument parameters
Working environment: 5-50 ℃, relative humidity 85%
Communication: SDI-12
Input voltage range: 8-33V
Power: ≤ 1.5W
Weight: 1.4Kg
Size: 58 × 17.5 × 7.6cm
Installation: 1 'pole, compatible with NuRail and other installation hardware.
measurement parameters
H2O mole fraction range: 0-60mmol/mol
Import flow rate: 0.3lpm (typical value)
System Requirements
Distance ultrasound: ≥ 2 meters
Installation height: ≥ 2 meters
waterproof rating
Tested according to IEC IP54 standard
output parameters
parameter |
description |
unit |
ET |
actual evapotranspiration |
mm |
LE |
Latent heat flux |
W/m2 |
H |
Sensible heat flux |
W/m2 |
VPD |
Vapor pressure difference |
KPa |
Pa |
atmospheric pressure |
KPa |
Ta |
air temperature |
℃ |
RH |
Relative humidity of the environment |
% |
AH |
Absolute humidity of the environment |
g/m3 |
SVP |
Saturated vapor pressure of the environment |
KPa |
Td |
dew point |
℃ |
Manufacturer and place of origin: United StatesLI-CORcompany