Welcome Customer !

Membership

Help

Nanjing Chipu Precision Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Nanjing Chipu Precision Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    Yinchun Road, Maigaoqiao Entrepreneurship Park, Qixia District, Nanjing City

Contact Now

Kaitaike integrated electromagnetic flowmeter manufacturer

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Advantages of Kaitaike integrated electromagnetic flowmeter manufacturer: 1. Z-small flow can measure 20.0L/h. 2. High voltage resistant external electrode. 3. Sensitive response and stable zero point

Product Details

Kaitaike integrated electromagnetic flowmeter manufacturer

Anatomical images


Sewage type electromagnetic flowmeter/Φ100mm


Self flowing electromagnetic flowmeter/Φ100mm


Anti corrosion electromagnetic flowmeter/Φ150mm

advantage:
  1Impurities and fibers do not affect the measurement
  2PTFE corrosion-resistant lining
  3Antibacterial and anti stick electrode
  4Accumulated flow measured in both positive and negative directions
  5Intelligent self rupture function

advantage:
  1Increase in magnetic field strength5times
  2Proficient in measuring ultra-low flow rate flow
  3Input impedance up to15Megaohm
  4Built in large magnetic steel
  5High current excitation

advantage:
  1Four electrode mechanism safety grounding
  2Ha ShiCAlloy electrode
  3PTFE lining is resistant to strong acids and alkalis
  4Stainless steel casing prolongs lifespan
  5Density conversion function, easy to calculate quality


Submersible electromagnetic flowmeter/Φ200mm


High temperature electromagnetic flowmeter/Φ300mm


Small caliber electromagnetic flowmeter/Φ10mm

advantage:
  1Used for orange red diving paint package10year
  2Protection level:IP68
  3Fully sealed glue filling process,No drip leaks

advantage:
  1High temperature resistance up to200degree
  2Choose high-temperature enameled coils
  3Using a mesh skeleton lining

advantage:
  1ThezuiSmall traffic can be measured20.0L/h 
  2External plug-in electrode with high voltage resistance
  3Sensitive response,Zero point stability

2、 Overview:
CP-LDE
seriesElectromagnetic FlowmeterThe measurement principle is Faraday's law of electromagnetic induction, and the main components of the sensor are: measuring tube, electrode, excitation coil, iron core, and magnetic yoke housing. It is mainly used to measure the volumetric flow rate of conductive liquids and slurries in closed pipelines. Including highly corrosive liquids such as acids, alkalis, salts, etc. This product is widely used in industries such as petroleum, chemical, metallurgical, textile, food, pharmaceutical, papermaking, as well as in fields such as environmental protection, municipal management, and water conservancy construction.

3、 Product features:
1. Measurement is not affected by changes in fluid density, viscosity, temperature, pressure, and conductivity;
2. Measuring inside the tube*Flowing components, no pressure loss, low requirements for straight pipe sections;
3. Series nominal diameterDN15~DN3000There are multiple options for sensor lining and electrode materials;
4. The converter adopts a novel excitation method, with low power consumption, stable zero point, and high accuracy. The flow range can reach1500:1;
5. The converter can be integrated or separated from the sensor;
6. The converter adopts16A high-performance microprocessor,2x16LCDDisplay, convenient parameter setting, and reliable programming;
7. The flowmeter is a bidirectional measurement system equipped with three integrators: forward total, reverse total, and differential total; Can display. Zhuang, reverse flow, and have multiple outputs: electric
Flow, pulse, digital communicationHART;
8. The converter adopts surface mounting technology(SMT)It has self checking and self diagnostic functions;

4、 Main technical data:
Technical data of the whole machine and sensors

execution standard

JB/T 92481999

Nominal Diameter

15、20、25、32、40、50、65、80、100、125、150、200、250、300、350、400、450、500、600、700、800、900、1000、1200、1400、1600、1800、2000、2200、2400、2600、2800The3000

zuihigh flow rate

15m/s

accuracy

DNl5~DN600

Indicating value:±0.3%(Flow rate)≥1m/s);±3mm/s(Flow rate)<1m/s)

DN700DN3000

Indicating value±0.5%(Flow rate)≥0.8m/S);±4mm/s(Flow rate)<0.8m/S)

Fluid conductivity

≥5uS/cm?

Nominal Pressure

4.0MPa

1.6MPa

1.0MPa

0.6MPa

6.3The10MPa

DNl5~DN150

DNl5~DN600

DN200~DN1000

DN700~DN3000

Special Orders

ambient temperature

sensor

25℃ten60℃

Converter and integrated model

10℃ten60℃

Lining material

Polytetrafluoroethylene, chloroprene rubber, polyurethane, perfluoroethylene propylene(F46)Add NetworkPFA

zuiHigh fluid temperature

body type

70℃

separated type

Polychloroprene rubber lining

80℃;120℃(Please specify when placing an order)

Polyurethane lining

80℃

PTFE lining

100℃;150℃(Please specify when placing an order)

Perfluoroethylene propylene(F46)

Add NetworkPFA

Signal electrode and ground electrode materials

stainless steel0Crl8Nil2M02TiHastelloy alloyCHastelloy alloyBTitanium, tantalum, platinum/iridium alloy, stainless steel coated with tungsten carbide

Electrode scraper mechanism

DN300DN3000

Connecting flange material

carbon steel

Grounding flange material

stainless steel1Crl8Ni9Ti

Imported protective flange materials

DN65DNl50

stainless steel1Crl8Ni9Ti

DN200~DNl600

Carbon steel and stainless steel1Crl8Ni9Ti

Shell protection

DNl5~DN3000Separable rubber or polyurethane lined sensor

IP65orIP68

Other sensorsBody type flowmeter and separation type converter

IP65

Distance (separated type)

The distance between the converter and the sensor is generally not more than100m

Converter technology data

power supply

communication

85265V,45400Hz

direct current

1140V

Operation keys and display

push-button

4A thin film button can be used to set and select all parameters, and can also be utilizedPCMachine(RS232)Programming the converter settings;

3lineLCDWide viewing angle, wide temperature range, backlit display;

第1Display traffic values in rows;

第2Display flow units in rows;

第3Display the percentage of traffic, total forward, total reverse, total difference, alarm, and flow rate.

Magnetic key type

2A magnetic key is used to display parameter selection and reset, utilizingPCMachine(RS232)Programming the converter settings;

2lineLCDWide viewing angle, wide temperature range, backlit display:

第1line:Magnetic key selection:Display traffic percentage, forward total amount, reverse total amount, difference total amount, alarm, and flow rate.

第2Row: Display traffic.

Internal integrator

Positive total, negative total, and differential total.

output signal

Unidirectional analog output

Fully isolated, load≤600D.(20mATime);

upper limit:021mAOptional, each levelLMA;

Lower limit:021mAOptional, each level1mA;

Programming for forward and reverse flow output modes.

Bidirectional analog output

The lower limit is. or4mA, other analog outputs in the same direction.

Bidirectional pulse output

Two outputs correspond to forward and reverse flow respectively,frequency0~800Hz,upper limit1800Hzoptional,each gearIHz;

Square wave or selected pulse width, selected upper limit of pulse width2.5SEach level1ms;

Passive isolation transistor switch output, capable of absorbing250mACurrent, withstand voltage35V.

Dual channel alarm output

Programmable alarm for high/low flow rate, air traffic control, fault status, positive/negative flow rate, analog over range, pulse over range, pulse small signal cutoff, with optional output polarity;

Transistor switch output with isolation protection,Absorbable250mAThe current,pressure resistance35V.(Not isolated from pulse output)

Digital Communication


RS232,RS485,HART


Selection of lining

Lining material

Main performance?

zuiHigh medium temperature

Scope of application

body type

separated type


Polytetrafluoroethylene(F4)

It's about chemical propertieszuiA stable plastic that can withstand boiling hydrochloric acid, sulfuric acid, nitric acid, and aqua regia, as well as concentrated alkali and various organic solvents. Corrosion caused by intolerance, high temperature, high flow rate liquid fluorine, liquid oxygen, and self oxygen.

70℃

100℃ 150℃(Special order required)

1Strong corrosive media such as concentrated acid and alkali. 2Sanitary media.

Perfluoroethylene propylene(F46)

同F4The wear resistance and negative pressure resistance are higher thanF4.

Ditto.


Polyfluoroethylene(Fs)

The upper limit of applicable temperature is lower than that of polytetrafluoroethylene, but the cost is also lower.

80℃


Polychloroprene rubber

1have*Good elasticity, high tensile strength, and wear resistance.2Resistant to corrosion in general low concentration acid, alkali, and salt media, but not resistant to corrosion in oxidizing media.

80℃ 120℃(Special order required)

Water, sewage, and weakly abrasive slurry.

Polyurethane rubber

1Wear resistance performance*.

2Poor corrosion resistance.

80℃

Neutral strong abrasion slurry, coal slurry, mud

Selection of imported protective flanges and grounding flanges (or grounding rings)

Type of flange

Scope of application

Grounding flange (or grounding ring)

Suitable for non-conductive pipelines such as plastic pipes, but sensors with grounding electrodes do not require them.

Import protection flange

Choose when the medium has strong wear resistance.


Selection of electrodes

electrode material

Corrosion resistance and wear resistance

stainless steel0Crl8Nil2M02Ti

Used for weakly corrosive media such as industrial water, domestic water, sewage, etc., suitable for industrial sectors such as petroleum, chemical, steel, as well as municipal and environmental protection fields.

HastelloyB

It has good corrosion resistance to all concentrations of hydrochloric acid below boiling point, as well as to non chlorinated acids, bases, and non oxidizing salt solutions such as sulfuric acid, phosphoric acid, hydrofluoric acid, and organic acids.

HastelloyC

Can withstand corrosion from non oxidizing acids such as nitric acid, mixed acids, or mixed media of chromic acid and sulfuric acid, as well as oxidative salts such as:Fe,”Cu”Corrosion caused by or containing other oxidants, such as hypochlorite solutions above room temperature and seawater corrosion

titanium

Capable of withstanding corrosion from seawater, various chlorides and hypochlorites, oxidizing acids (including fuming sulfuric acid), organic acids, and alkalis. Not resistant to corrosion by relatively pure reducing acids (such as sulfuric acid, hydrochloric acid), but if the acid contains oxidants (such as nitric acid,...)Fc++CuWhen the temperature is++, the corrosion is greatly reduced.

Tantalum

It has excellent corrosion resistance and is very similar to glass. Except for hydrofluoric acid, fuming sulfuric acid, and alkali, it can almost withstandCut chemical media (including boiling point hydrochloric acid, nitric acid, and...)l 50℃Corrosion caused by sulfuric acid. Dig in alkali; Corrosion resistance.

Platinum/titanium alloy

Almost capableCut chemical media, but not suitable for aqua regia and ammonium salts.

Stainless steel coated with tungsten carbide

Used for non corrosive and highly abrasive media.

Note: Due to the wide variety of media and the complex factors such as temperature, concentration, and flow rate that affect their corrosiveness, this table is for reference only. Users should make their own choices based on the actual situation, and if necessary, conduct corrosion resistance tests on the selected materials, such as hanging plate tests.

5CP-LDESeries instrument selection

◆Range confirmation

The general industrial electromagnetic flowmeter measures the flow rate of the measured medium2~4m/sIn special circumstances, it is advisable to,zuiThe low flow rate should not be less than0.2m/s,zuiThe height should not exceed8m/sIf the medium contains solid particles, the commonly used flow rate should be less than3m/sTo prevent excessive friction between the lining and electrodes; For viscous fluids, the flow velocity can be selected to be greater than2m/sA higher flow rate helps to automatically eliminate the effect of viscous substances attached to the electrode, which is beneficial for improving measurement accuracy.

within the rangeQUnder the determined conditions, the above flow rate can be usedVThe range determines the diameter of the flowmeterDThe size of is calculated by the following formula:

Q=πD2V/4
Q:
Flow rate (㎡)/h)D:inner diameter of pipeV: Flow rate(m/h)

Range of electromagnetic flowmeterQShould be greater than expectedzuiA large flow rate value, while a normal flow rate value is slightly larger than the full-scale scale of the flow meter50It is appropriate.

◆ CP-LDEReference flow range of series electromagnetic flowmeter

calibermm

flow rangem3/h

calibermm

flow rangem3/h

φ15

0.06~6.36

φ450

57.23~5722.65

φ20

0.11~11.3

φ500

70.65~7065.00

φ25

0.18~17.66

φ600

101.74~10173.6

φ40

0.45~45.22

φ700

138.47~13847.4

φ50

0.71~70.65

φ800

180.86~18086.4

φ65

1.19~119.4

φ900

228.91~22890.6

φ80

1.81~180.86

φ1000

406.94~40694.4

φ100

2.83~282.60

φ1200

553.90~55389.6

φ150

6.36~635.85

φ1600

723.46~72345.6

φ200

11.3~1130.4

φ1800

915.62~91562.4

φ250

17.66~176.25.

φ2000

1130.4~113040.00

φ300

25.43~2543.40

φ2200

1367.78~136778.4

φ350

34.62~3461.85

φ2400

1627.78~162777.6

φ400

45.22~4521.6

φ2600

1910.38~191037.6

CP-LDESelection spectrum of series electromagnetic flow meters

model

caliber


CPLD

15~2600



code name

electrode material


K1

316L

K2

HB

K3

HC

K4

titanium

K5

Tantalum

K6

Platinum alloy

K7

Stainless steel coated with tungsten carbide


code name

Lining material


C1

PolytetrafluoroethyleneF4

C2

Perfluoroethylene propyleneF46

C3

PolyfluoroethyleneFS

C4

Polyvinyl rubber

C5

Polyurethane rubber


code name

function

E1

0.3level

E2

0.5level

E3

1level

F1

4-20Madc,load≤750Ω

F2

0-3khz,5vActive, variable pulse width, output effective frequency

F3

RS485interface

T1

Room temperature type

T2

high-temperature type

T3

Ultra high temperature type

P1

1.0MPa

P2

1.6MPa

P3

4.0MPa

P4

16MPa

D1

220VAC±10%

D2

24VDC±10%

J1

Integrated structure

J2

Split type structure

J3

Explosion proof integrated structure