10 µ s rapid response
Wide temperature measurement range, 160-3500 ℃
Excellent optical lens with a minimum spot size of 0.7 mm
Optional LED or viewfinder aiming
Special cut-off filters available for laser processing
Capable of triggering input function
Can communicate with PC through USB
KLEIBER company KMGA 740 high-speed thermometerThe response time is only 10 μ s, which can be used to monitor the rapid temperature changes of objects
KLEIBER company KMGA 740 high-speed thermometerThe standard configuration includes a pyrometer with zoom or macro lens, a desktop unit with integrated display, power supply, USB interface, and testing software that can run on a PC The pyrometer is connected to the 12 pin interface on the back of the desktop unit. The PC is also connected through the USB port on the back of the desktop unit. The front of the desktop unit has a trigger input interface and a 0/4-20mA analog output interface.
The accompanying software has a user-friendly interface and can display recorded temperature curves on a PC screen, as well as set parameters for multiple pyrometers. This software can simultaneously record data from up to 4 pyrometers and generate dynamic curves.
For the convenience of aiming at the target, the pyrometer is equipped with LED aiming lights, and the size of the light spot is consistent with the minimum measurable target size. Users can also choose the viewfinder aiming method according to specific applications.
Laser applications (laser cutting, laser welding, laser brazing, etc.)
Research and development/testing of materials
Internal combustion engine testing
Airbag testing
Chip temperature measurement
Turbine blade testing
Plasma measurement
Explosion process
| temperature range | |
|---|---|
| Kmga 740 |
160 . .. 1000 °C 300 . .. 1400 °C 600 . .. 1600 °C 300 . .. 2300 °C 800 . .. 2300 °C 500 . .. 2500 °C 350 . .. 3500 °C |
| measurement parameters | |
wavelength |
0.85 - 1.05 µm 1.58 - 1.8 µm 1.58 - 2.2 µm 2.0 - 2.2 µm |
| Emissivity ε | 0.1-1.0, continuously adjustable |
| measurement accuracy (ε = 1, t 95= 1 s, Tamb.= 25 °C) |
0.75% of the reading at ° C |
| repeatability accuracy (ε = 1, t 95= 1 s, Tamb.= 25 °C) |
0.3% of the reading at ° C |
| Response time t95 | 10 µs |
| Electrical parameters | |
| power supply | 230 V AC , 50-60 Hz |
| communication | |
|---|---|
| connect | 12 pin connector |
| analog output |
Current output: 0-20 mA or 4-20 mA (linear) switchable BNC output: 0-10V |
| Digital output | USB |
| trigger input | TTL level, maximum voltage 15V |
| optical parameters | |
| aim | LED aiming light or viewfinder aiming |
| lens |
Focusing lens 2.5-28 mm @ a=450 . .. 3000 mm macro lens 0.7-1.0 mm @ a=140 . .. 150 mm |
| environmental parameters | |
| Protection level | IP 54 (DIN 40 050), pyrometer IP 20 (DIN 40 050), Desktop unit |
| ambient temperature |
0 - 40 °C 0-80 ° C, water-cooled |
| Storage temperature | -20 - 70 °C |
| relative humidity | non-condensing |
| L*W*H |
Pyrometer: 170 * 70 * 70 mm Desktop unit: 335 * 310 * 155 mm |
| CE certification: | According to the EU Directive on Electromagnetic Immunity |