- Phone
-
Address
No. 1210 Dongfang Avenue, Wuzhong Economic Development Zone, Suzhou
Suzhou Changliu Purification Technology Co., Ltd
No. 1210 Dongfang Avenue, Wuzhong Economic Development Zone, Suzhou
Our company regards "building domestically produced laser particle size instruments" as our responsibility, with the policy of creating brands through technology, entering the market through quality, and winning the world through reputation. We are committed to creating ultra stable and cost-effective domestically produced laser particle size instruments.
CL-JG900AIntelligent fully automatic wet laser particle size analyzerIt is a portable integrated particle size analyzer newly launched by our company, which has many advantages such as small size, large range, and high degree of automation. The whole machine has only750mm*270mm*315mm (including integrated ultrasound, dispersion, and circulation), with a small volume but a range of 0.1 μ m-500 μ m. CL-JG900A belongs to the wet process fully automatic laser particle size analyzer, which adopts international standardsMie's scattering principle and converging light Fourier transform optical path. The high-density probe and seamless full range connection testing method ensure the accuracy and repeatability of the test results.
The operation process of CL-JG900A is fully controlled by the computer automatically. The schematic diagram of the control system is as follows:

Schematic diagram of control system for intelligent laser particle size analyzer

Optical path automatic centering function diagram
Main performance characteristics of CL-JG900A laser particle size analyzer:
★ Advanced optical path design:The CL-JG900A adopts converging light Fourier transform testing technology to ensure maximum range at the shortest focal length, effectively improving the instrument's resolution capability; *The high-density detection unit enables the 3100-L to have * small particle testing capability, and the high-density detection unit enables the CL-JG900A to have * full range seamless testing capability.
★fully sealedFiber optic semiconductor laser:The CL-JG900A adopts a highly stable and long-life Mitsubishi fully sealed fiber semiconductor laser from Japan. The excellent stability gives the particle size analyzer * test repeatability. The laser power of the CL-JG900A is adjustable, and the maximum laser power is also up to 20mw.
★Fully automated testing:Truly automated testing, all you need to do is insert the sample, without any interference or manual selection of data.
★ Ultrasonic anti dry burning function:CL-JG900A can achieve ultrasonic anti dry burning function, avoiding damage to the ultrasound in the absence of water.
★ New SOP self editing function:To meet the testing needs of different samples, NKT5200-H has implemented SOP self editing function, which can edit different testing processes according to different samples. After one editing and saving, it can be directly retrieved and used the next time.
★ Dustproof and shockproof design:The instrument has undergone a sealed design, significantly improving the service life of internal components. *The anti-seismic structure can effectively avoid the interference of external vibrations on the instrument, making the test results more stable and reliable.
★ Light path adjustment:The computer remotely controls the precision self-locking motor, precision guide rail, precision controller, and software system, with a minimum step distance of 1 micron, ensuring that the laser beam focus always passes through the center point of the detector, improving the accuracy and repeatability of the test results. The automatic centering system is a standard configuration for all models of Nike laser particle size analyzers..
★Bubble free design:The new design ensures that no bubbles enter the test sample window during the entire test, avoiding interference from bubbles.
★Channel steel guide rail:The optical path guide rail has been upgraded from aluminum alloy to thickened channel steel, making the optical path system more stable and reliable, while greatly reducing the impact of temperature and humidity on the optical path.
★Sample residue free design:The instrument pipeline and drainage structure have been optimized, and there is no residual liquid in the instrument pipeline and circulation pump to avoid affecting the next test data.
★Sample window quick change device:The newly designed sample window quick change device makes sample window replacement more convenient and efficient.
Intelligent fully automatic wet laser particle size analyzerMain technical parameters:
Specification Model |
CL-JG900A (standard) |
|
execution standard |
ISO 13320-1:1999; GB/T19077.1-2008 |
|
test scope |
0.1μm -500μm |
|
Number of detector channels |
65 |
|
Accuracy error |
<1% (D50 value of national standard sample) |
|
repeatability error |
<0.5% (D50 value of national standard sample) |
|
No need to discharge bubbles |
Equipped with bubble free design, the data is more accurate without bubble interference |
|
Misoperation protection |
The instrument has self-protection function against misoperation, and does not respond to misoperation |
|
Laser parameters |
Imported fiber optic output high-power laser with λ=635nm and p>20mW |
|
optical path alignment |
Automatic calibration of optical path |
|
Dispersion method |
ultrasound |
Frequency: f=40KHz, power: p=100W, time: freely adjustable; Equipped with ultrasonic anti dry burning feature |
Circulation and mixing |
Integrated design of circulation mixing, speed adjustable from 100-4000rpm |
|
circulating flow |
Rated flow rate: 0-10L/min, adjustable rated power: 20W |
|
sample pool |
Self designed boiling sample pool with better dispersion effect, capacity: 190-600mL can be tested normally |
|
Dustproof and shockproof design |
The whole machine adopts dust-proof and shockproof design |
|
Software features |
Analysis mode |
Including free distribution, R-R distribution, lognormal distribution, and hierarchical statistical models, it meets the different requirements of different industries for the statistical methods of particle size of the tested samples |
statistical method |
Volume distribution and quantity distribution to meet different statistical methods for particle size distribution in different industries |
|
statistical comparison |
Statistical comparative analysis can be conducted on multiple test results, which can significantly compare the differences in test results between different batches of samples, samples before and after processing, and test results at different times. This has strong practical significance for industrial raw material quality control |
|
DIY on your own |
User defined data to be displayed, calculated as percentages based on particle size, particle size based on percentages, or based on |
|
Display Template |
Calculate the percentage of particle size range to meet the characterization requirements of different industries for particle size testing. Distance, consistency, interval accumulation, etc |
|
Test Report |
The test report can be exported in various forms such as Word, Excel, images (Bmp), and text (Text), meeting the needs of viewing test reports in any situation and citing test results in scientific research articles |
|
Multilingual support |
Chinese and English language interfaces are supported, and other language interfaces can also be embedded according to user requirements. |
|
Intelligent operation mode |
Truly automatic unmanned intervention operation, without human interference, you only need to follow the prompts to add the test sample, and the repeatability of the test results is better. |
|
Operation Mode |
One click fully automatic software operation mode |
|
test speed |
<1min/time (excluding sample dispersion time) |
|
volume |
750mm*270mm*315mm |
|
weight |
25Kg |
|