1. Equipment: portable host, external clip on ultrasonic sensor (one pair), signal line, coupling agent
2. Tools: tape measure, sandpaper, clean cloth
3. Confirm:
Pipeline material, outer diameter, wall thickness, medium
Installation point front and rear straight pipe sections: front ≥ 10D, rear ≥ 5D
The pipeline must be fully filled
Polish the installation position with sandpaper, remove rust, paint, and dirt
Wipe clean with a cloth to keep it smooth, dry, and rust free
Select medium: water/diesel/other liquids
Input: Pipe outer diameter, wall thickness, material, nominal diameter
The host automatically calculates the installation distance of the sensor
Apply coupling agent evenly on the contact surface of the sensor
Covering the entire probe surface without bubbles or gaps
Locate based on the center distance displayed on the host
Use zip ties or fixtures to firmly attach the sensor to the pipe wall
Two sensors parallel, aligned, and not offset
Observe the hostSignal strength, transmission time, signal-to-noise ratio
Normal standard:
Signal strength>90%
Signal to noise ratio>25 dB
When the signal is insufficient:
Re polish the pipeline
Add coupling agent
Adjust sensor position and alignment
After the signal stabilizes, enter the measurement interface
The installation is completed when the instantaneous flow and cumulative flow are displayed normally
Sensors are installed on the same side of the pipeline
Suitable for: small caliber, thin pipe wall, good signal
Sensors are installed on both sides of the pipeline, facing each other
Suitable for: large-diameter, thick walled pipes, sewage, and high signal attenuation
1. It is necessary to ensure that the pipeline is full, and if it is not full, the measurement will be inaccurate
2. Avoid installation points such as welds, elbows, valves, pumps, and reducers
3. The sensor must be firmly attached and not loose
4. The coupling agent should not be too small and there should be no bubbles
5. Outdoor installation of sensors to avoid direct sunlight exposure
6. Avoid parallel signal lines with strong electrical cables to prevent interference
Stable signal strength
Stable traffic values without any fluctuations
Positive and negative flow directions are correct
No alarm prompt
remark
The displayed prices in the system are for reference only and do not represent the actual transaction price.Flow meters may vary in price due to different specifications, calibers, configurations, and operating conditions. Accurate pricing should be provided based on the actual operating conditions after selection.