- Phone
-
Address
Xiatun Village, Guang'an Town, Dacheng County, Langfang City, Hebei Province
Langfang Qianbang Fireproof Materials Co., Ltd
Xiatun Village, Guang'an Town, Dacheng County, Langfang City, Hebei Province
Introduction to Indoor Expansion Steel Structure Fireproof Coating
1、 Core Definition and Classification
-Fire prevention mechanism: using organic resin as the base material, combined with carbon source, acid source, and gas source (expansion system); When exposed to fire (about 120-200 ℃), a chemical reaction occurs, rapidly expanding to form a porous carbide layer 10-50 times thicker than the original, blocking heat conduction and oxygen contact, and prolonging the fire resistance time of steel components.
-Coating classification (by thickness)
-Ultra thin type: ≤ 3mm, good decorative, suitable for exposed components, fire resistance limit 0.5-1.5h
-Thin: 3-7mm, balancing fire resistance and decoration, suitable for load-bearing components, with a fire resistance limit of 1.0-2.5h
3、 Performance characteristics
-Highly decorative: The coating is flat and smooth, and can be adjusted to multiple colors, suitable for indoor decoration
-Convenient construction: brush coating/roll coating/spray coating are all available, with controllable single coating amount and short construction period
-Environmental safety: water-based formula, low VOC, no pungent odor, suitable for enclosed spaces
-Good adhesion: tightly bonded with steel, adaptable to slight deformation, not easy to crack or peel off
4、 Scope of application
-Typical scenarios: Indoor exposed or semi exposed steel components (steel columns, steel beams, trusses, floor slabs, etc.) in commercial complexes, office buildings, airports, sports venues, industrial plants, stations, underground garages, etc
-Not suitable for outdoor environments with no obstruction, strong corrosion, high temperature and humidity (such as bathrooms), etc
5、 Key points for construction and storage
1. Substrate treatment: rust removal up to Sa2.5 or St3 level, removal of oil stains and floating dust, and application of matching primer
2. Construction environment: temperature 5-35 ℃, relative humidity ≤ 85%, avoid rainy/condensation construction
3. Coating control: The first dry film should be 0.3-0.5mm, with an interval of 4-8 hours (after surface drying) before applying the next coat; Each subsequent layer should be 0.5-0.8mm until the design thickness is reached
4. Storage conditions: Sealed and stored in a cool and dry place, with a shelf life of 6-12 months, avoiding freezing