E-mail
kew689@126.com
-
Phone
15805823165
-
Address
www.kw689.com
Nanjing Calvin Biotechnology Co., Ltd
kew689@126.com
15805823165
www.kw689.com
In vitro microvascular tension measurement systemTechnical Specifications
1. The device adopts a 6.8-inch LCD touch screen for human-machine dialogue.
2. Number of channels: 4 channels, independent temperature adjustable
3. Micro spiral ruler: Three dimensional adjustable manual rotation stretching, accuracy 0.01mm
4. Applicable sample size: The clamp type fixation bracket can accommodate microvessels with diameters ranging from 30 microns to 450 microns; Steel needle fixed bracket can measure large blood vessels over 450 microns, up to a maximum of 7 millimeters. Bath tank specifications: diameter 40mm, depth 10mm
6. The bath constant temperature plate can be disassembled and placed under a microscope for operation
7. Bath material: stainless steel
8. Bath capacity: 10 ml
9. Bath waste liquid suction: automatic, flow rate 70ml/min
10. Bath inlet: Needle valve, independent control, each bath includes an independent bath cover, allowing for rapid evaporation of the solution. The bath cover has inlet, inlet, and outlet ports
11. Tension range: 0-500mN
12. Tension accuracy: 0.1mN
13. Temperature range: ambient temperature -45 ℃
14. Temperature accuracy: 0.1 ℃, temperature stability: ± 0.2 ℃
15. Temperature probe: built-in
16. Output display: Tension (mN) (interface customizable)
In vitro microvascular tension measurement systemTechnical parameters of data collection system:
Hardware section
1. Input channel: 4
2. Magnification range: 0-5 V
3. Input impedance: 1 M Ω
4. Low pass filtering: 1Hz-2KHz
5. Interface type: 8-pin connection method.
6. Analog to digital conversion accuracy: 16 bits
7. Maximum sampling rate: 100KHZ
8. Transmission interface: USB or Type-C transmission
Software section:
1. Input channel: 4
2. Magnification range: 0-5 V
3. Input impedance: 1 M Ω
4. Low pass filtering: 1Hz-2KHz
5. Interface type: 8-pin connection method.
6. Analog to digital conversion accuracy: 16 bits
7. Maximum sampling rate: 100KHZ
8. Transmission interface: USB or Type-C transmission
Software section:
1. Capable of online publishing;
2. Two different recording modes can be used: continuous recording or stacked average recording;
3. Can calculate (+/-) dp/dt, maximum value, minimum value, average value, peak to peak value, heart rate, slope, differentiation, integration, exponential operation, logarithmic operation, area, deviation, standard deviation, absolute value, trigonometric function, curve smoothing, etc;
4. Equipped with real-time automatic display ratio adjustment function, the signal does not exceed the visible range;
5. With annotation function, it can be added during or after recording, enabling one click annotation during recording;
6. The data can be exported as TXT text, EXECL format files, Binary format, EDF universal format, Neurxplorer files, etc;
7. Hardware parameter settings can be independently saved as setting files, which can be quickly called as experimental templates;
8. There are professional module analysis software for blood pressure, electrocardiogram, dose-response relationship, peak histogram, heart rate variability, etc. to facilitate experimental personnel's analysis and data, which can be combined with amplifiers to achieve corresponding functions;
9. Includes professional version analysis software