IEC body module (elliptical)

NegotiableUpdate on 12/30
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
BX-IEC Body IEC Body Module (Elliptical) is a high-precision body imaging performance testing module designed strictly in accordance with the International Electrotechnical Commission (IEC) standards and NEMA NU2-2007 specifications. The phantom adopts an elliptical cylindrical design and integrates six hemispherical structures of different sizes (10mm to 37mm) internally, effectively simulating the shape and radiation distribution of the human torso. It is specifically designed to evaluate the image quality performance of positron emission tomography (PET) and computed tomography (CT) systems.
Product Details


IEC body moduleellipse

product structure

A. 1. Technical Specifications

A. 1.1. ComplianceNEMA NUThe requirements of 2-2007.

A. 1.2. The inner diameters of the six hemispheres are: 10 mm 13 mm 17 mm 22mm 28mmAnd 37mm.

A. 1.3. The distance between the plane of the sphere and the inner wall is approximately ≤ 70mm.

A. 1.4. Cylinder volume approximately ≥ 9.7 L。

A. 1.5. The outer diameter of the cylinder is: 51mm.



IEC body module (elliptical)Core functions and purposes

core positioningQuantitative calibrator for PET/CT equipment

Main functions: Used for evaluationQuantitative accuracy and basic image quality of PET and PET/CT systems.

target devicePositron Emission Tomography/Computerized tomography (PET/CT) system.

Key detection indicators

·Image resolution: The evaluation system can clearly distinguish the minimum distance between two adjacent radiation sources.

·Image uniformity: Testing the consistency of image counting in a uniform radiation source.

·System sensitivity: The ability of testing equipment to detect signals from small radioactive sources.

·Quantitative accuracy: Ensuring the matching degree between image pixel values and real radiopharmaceutical concentrations is crucial for evaluating tumor efficacy.

Application scenarios

Performance acceptance of PET/CT system

Used for basic performance verification of new equipment installation to ensure compliance with factory standards and clinical diagnostic requirements.

Daily quality control and regular calibration

The hospital's nuclear medicine department or imaging center can regularly use this phantom for system performance monitoring and stability evaluation.

Research and Optimization of Image Quality

Support the development of reconstruction algorithms, optimization of scanning protocols, and other scientific research work to improve the accuracy of quantitative analysis of images.

Third party testing and compliance certification

Provide standardized testing tools for medical device testing institutions and support compliance verification with relevant regulations.

Teaching and Training

Suitable for medical engineering teaching and technical personnel training, helping to understandPET/CT imaging principle and performance parameters.