Welcome Customer !

Membership

Help

Tianjin Parallel Saisi Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Tianjin Parallel Saisi Technology Co., Ltd

  • E-mail

  • Phone

  • Address

    Fuyuan Road North Test Entrepreneurship Headquarters Base, Wuqing Development Zone, Tianjin City

Contact Now

ICP-MS tuning solution SPEX CL-ISM1

NegotiableUpdate on 05/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

ICP-MS tuning solution SPEX CL-ISM1 $r $nPlasmaCAL calibration standard solution can provide various single element standard solutions and mixed element standard solutions for plasma spectroscopy. For accurate results, calibrate your instrument. Calibration of instruments, including ICP-OES and ICP-MS, is an important step in many indirect measurement methods. In order to obtain accurate analysis results, several important factors need to be considered during the calibration process: $r $n • Precision (uncertainty) of the calibration solution, such as 1006+/-4 ppm

Product Details

ICP-MS tuning solution SPEX CL-ISM1The detailed information is as follows:



ICP-MS internal standard calibration solution (7 elements)

Equivalent to SPEX CL-ISM1, Agilent 5183-4681

Purpose: Signal drift correction in ICP-MS testing; The element mass is uniformly distributed in low, medium, and high levels

Part number: 140-111-081

元素: Bi,Ge, In,6Li, Sc,Tb, Y

Concentration: 10ppm

Medium: 5% HNO3

Volume (ml): 125ml




ICP-MS internal standard calibration solution precious metal mixed standard sample (10 elements)

equivalent PE N930-0235 Agilent 8500-6948

Purpose: General research and quantitative analysis; Mainly used forICP-MS

Part number:700-101-105

Element:Au , Hf Ir , Pd , Pt , Rh , Ru, Sb, Sn, Te

Concentration: 10ppm

medium: 10% HCl

volume (ml):2X25ml



ICP-MS internal standard calibration solution with 8 elements

Equivalent to Agilent5188-6525

Part number:140-111-201

元素: 6Li, Sc, Ge, Rh, In, Tb, Lu, Bi.

Concentration:100ppm

medium: 5% HNO3

volume (ml):125ml



Multi element calibration standard sample-2A (27 elements)

Equivalent to Agilent8500-6940

Part number:140-109-111

Element:Ag,Al,As,Ba,Be,Ca,Cd,Co,Cr,Cs,Cu,Fe,Ga,K,Li,Mg,Mn,Na,Ni,Pb,Rb,Se,Sr,Tl,U,V,Zn

Concentration:10ppm

medium: 5% HNO3

volume (ml):125ml

reagent bottle 2 (Part number:140-110-111)

contain10 mg/L Hg, with a substrate of 5% HNO3 solution.


ICP-MS tuning solution 6 elements)

Equivalent to Agilent5190-0465

Part number:AQ0-122-601

Element:Li、Mg、Y、Ce、Tl、Co

Concentration:10ppm

medium5% HNO3 Agilent matrix is a 2% HNO3 solution

volume (ml):125ml



ICP-MS tuning solution 6 elements)

Equivalent to Agilent5185-5959

Part number:AQ0-081-035

Element:Li、Mg、Y、Ce、Tl、Co

Concentration:1ppb

medium5% HNO3 Agilent matrix is a 2% HNO3 solution

volume (ml): 500ml Agilent is2 x 500 mL bottles



ICP-MS reserve tuning solution 5 elements)

Equivalent to Agilent5188-6564

Part number:AQ0-103-851

Element:Li、Y、Ce、Tl、Co

Concentration:10ppm

medium: 2% HNO3

volume (ml):125ml

ICP-MS tuning solution SPEX CL-ISM1For more information, please contact us!


Parallel Saisi provides you with a range of ICP-OES/ICP-MS standard solutions and quality control standard solutions. The EPA Method 200.7 covers the routine monitoring requirements for metal and non-metal elements in water and wastewater using ICP-OES for vertical or horizontal observation. The EPA Method 200.8 includes the use of ICP-MS to analyze elements specified in groundwater, surface water, drinking water, and wastewater. The EPA Method 6010c, combined with the Toxicity Characteristic Leaching Procedure (TCLP) or Extraction Procedure (EP) for solid waste, specifies the use of ICP-OES to determine 31 elements in groundwater, industrial and organic waste, soil, silt, and sediment.