Hydrogen oxygen analyzerThe XTP601-EX rugged, linear, and stable XTP601 oxygen analyzer is suitable for measuring gases such as hydrogen, nitrogen, biogas, or carbon dioxide. The sensors of this analyzer are installed in an IP66 rated enclosure, making it suitable for a wider range of fields. After installing the flame arrester, the analyzer has explosion-proof performance and can be used in hazardous environments.
highlight
• Ordinary or ATEX, IECEx, CCSAUS, TC, TR&Ex hazardous area certification
• Optional range: 0-0.5%, 0-50%, 20, 80 or 90-100%
Touch sensitive display that can be calibrated or adjusted without the need for explosion-proof certification application
Excellent accuracy, better than 1% of full scale
• Zero drift stability, with monthly drift less than 0.25%
• Output includes RS485 and two 4-20mA channels (under NAMUR NE 44 standard)
Low maintenance cost, requiring minimal maintenance
application
Monitoring of inert protective gases during hydrocarbon production process
Inert gas monitoring in the pharmaceutical or chemical industry
• Biogas, landfill sites, and biogas plants
Furnace gas control in the metallurgical industry
• Catalytic reforming
N2 generator
O2 generator
Hydrogen oxygen analyzerTechnical Specifications
performance
Measurement technology - Thermomagnetic oxygen sensor
Gas process gas sampling, non condensing, solid particles<5 μ m
Measurement range from 0-0.5% up to 0-50% 20, 80 or 90-100%
Display resolution 0.01% for standard range 0.1% for over range
Display Type Backlight LCD
Accuracy
(excluding special ranges) ± 0.02% oxygen content or<± 1%, whichever is greater
Special range accuracy (80/90-100%)<0.2% O2
Response time (T90) HSR function needs to be enabled within 15 seconds
Repeatability ± 0.2% or 0.01% oxygen content, whichever is greater
Linear ± 0.5% or 0.05% oxygen content, whichever is larger
Zero stability ± 0.25% of monthly range
Range stability ± 0.25% of monthly range
Sample gas flow rate GP1 and GP3: 100! 500 ml/min
EX1, EX3, and GP2: 270~330 ml/min
Sample gas pressure 0.75~2 BarA
Sample gas temperature 5~+55 ° C
Standard maximum (+45 ° C)
Sampling room temperature standard+50 ° C (optional range and gas of+55 and+60 ° C)
The background gas analyzer is calibrated under process background gas and standard gas
For N2, CO2, CH4, H2&biogas
Electrical parameters
Analog input 2-channel 4-20 mA input
One way for external sensors, which can be displayed on the screen
Another way for dynamic compensation of process conditions
Analog output 2 channels 4-20 mA output
The first output range is consistent with the calibration range of the instrument
The second path is 0-100% user configurable
Alarm Two way Single Magnetic Dual Transformation (SPCO) Relay Numerical Alarm (250 V
5 A max)
Data collection users can collect the output signals of the analyzer through digital communication
The machine can store the maximum and minimum of 40 alarm points and oxygen content readings
Value, these data are all accompanied by date and time explanations
Digital Communication Modbus RTU Based on RS485 Protocol
Power supply 24 V DC; Maximum 1.5 A
The cable entry analyzer is equipped with 3 x M20 cable entries. Cable gland, conduit
The entrance and plug are provided as attachments
operating conditions
Environmental temperature 5~+55 ° C
Environmental pressure 750mbar~1250mbar
mechanical parameters
Preheating time<25 minutes
Stability time 5 minutes
Size 234 x 234 x 172mm (w x d x h)
Weight 9.7kg
Gas path material 316&430F stainless steel, silicone glass, platinum 3M 2216 adhesive
O-ring material: silicone, fluororubber or synthetic rubber
Gas connections EX1, EX3&GP2: 1/8 "NPT (cathode)
GP1 and GP3: 1/4 "NPT (cathode)
Protection level IP66, NEMA 4X
Hazardous Area Certification
ATEX II 2GD Ex d IIB+H2 T6 Gb
Ex tb IIIC T85°C Db IP66
IECEx Ex d IIB+H2 T6 Gb
Ex tb IIIC T85°C Db IP66
CCSAus Class I, Division 1, Groups B,C,D, T6
INMETRO Ex d IIB+H2 T6 Gb
Ex tb IIIC T85°C Db IP66
TC TR Ex 1 Ex d IIB+H2 T6 Gb
Weekly sealing ring
Under ATEX and IECEx environments
The temperature range
硅: Ta = -40°C~ +55°C
Fluororubber: Ta=-15 ° C~+55 ° C