Welcome Customer !

Membership

Help

Mingyu Instrument (Huai'an) Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Mingyu Instrument (Huai'an) Co., Ltd

  • E-mail

  • Phone

  • Address

    No. 88 Huancheng West Road, Jinhu County, Huai'an City, Jiangsu Province

Contact Now

Hydraulic fully automatic pressure calibration table

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The MY-QZDY hydraulic fully automatic pressure calibration table can have both external and internal pressure modules, with full coverage. During calibration, there is no need to replace the module, truly achieving fully automatic calibration of pressure (differential pressure) transmitters, pressure switches, precision pressure gauges, ordinary pressure gauges, and other pressure instruments, as well as precision pressure measurement. The use of a set system can replace manual piston pressure gauge calibration, making operation convenient and simple.

Product Details

MY-QZDY typeHydraulic fully automatic pressure calibration tableIt can be equipped with both external and internal pressure modules, with full coverage. During calibration, there is no need to replace the module, truly achieving fully automatic calibration of pressure (differential pressure) transmitters, pressure switches, precision pressure gauges, ordinary pressure gauges, and other pressure instruments, as well as precision pressure measurement. The use of a set of systems can replace manual piston pressure gauge calibration, with convenient and simple operation. The calibration process does not require manual operation, and even personnel without work experience can be competent in calibrating pressure instruments. The calibration work is scientific and standardized, with automatic data recording, automatic error analysis, and automatic generation of calibration reports, improving work efficiency and achieving scientific calibration management. If this system is adopted, other manual verification stations do not need to be configured extensively or may not be equipped.Hydraulic fully automatic pressure calibration tableIt can be equipped with built-in HART function to replace the HART controller, set or calibrate the range of the HART transmitter, force the output current of the HART transmitter to a fixed value (such as 20mA, 12mA, 4mA), set linear or square root function, and can reset the pressure sensor of the transmitter to HART, which is more convenient to use than the HART controller.


Advantages of fully automatic pressure calibration table:

Before leaving the factory, the pressure module underwent 1000-2000 pressure fatigue tests to eliminate residual stress on the sensor; Temperature compensation and calibration tests were conducted at (0-50) ℃, and the annual stability of the system was significantly improved.

It can be equipped with either an internal pressure module or an external pressure module. The metrological verification regulation "Automatic Standard Pressure Generator" is about to be released. In addition to verifying accuracy, the fully automatic pressure calibration table must also test control performance such as overshoot, control stability, control response time, etc. Both internal and external pressure modules must be sent for inspection as a complete system. Equipped with a built-in pressure module and fully automatic pressure calibration table, the built-in pressure module comes with warranty and dual channel calibration, and does not require any accessories during use.

Not only can it automatically calibrate pressure transmitters, but it can also automatically calibrate pressure switches. The calibration time for single point switches is about 2 minutes, and the calibration time for double point switches is about 4 minutes. The tripping and resetting points of the switch can be automatically tested without human intervention during the verification process.

Built in HART function, the calibration bench can display all HART parameters and perform functional operations related to the calibration transmitter on one screen, making it very convenient to use. The external precision pressure calibrator displays and operates HART parameters on two pages.

The gas-liquid boundary point conforms to the convention of 300psi, and the gas-liquid boundary point is 2.5MPa or 1.6MPa. Ensure the calibration accuracy of low-pressure range instruments.

Set up the sewage function, so that sand, dirt, and other substances brought in by the calibration meter can be discharged from the sewage outlet.

Install a gas-liquid separator on the pressure table to ensure the accuracy of the pressure sensor.

At standard atmospheric pressure, vacuum can be maintained at -100kPa.

The screen comes with an instruction manual, which can be used without a paper manual.

Can be equipped with an external pressure module.

Technical points:

1. Working medium: Transformer oil or purified water is used, and no external high-pressure gas source or air discharge is required during calibration.

2. Built in pressure module range: (3-60) MPa.

3. Custom calibration range: any value between (3~60) MPa.

4. Measurement unit: MPa.

5. Pressure display resolution: 5 digits.

6. Pressure accuracy: 0.02 or 0.05 level.

7. Current accuracy: 0.02 or 0.05 level.

8. Voltage control accuracy: ± 5 words.

9. Standard calibration points: 0%, 25%, 50%, 75%, 100% of the measuring range, automatic return. The computer can be set arbitrarily.

10. Custom calibration point: arbitrary.

11. Automatic voltage stabilization time at the verification point: 20 seconds, adjustable between 10 and 240 seconds.

12. The entire process time for automatic calibration of the transmitter (9 o'clock voltage stabilization) is about 5 minutes.

13. Pressure switch calibration time: about 2 minutes.

14. Equipped with HART controller function. (The HART screen is as follows)

Fully automatic pressure calibration table HART screen


15. Security protection: protection against overvoltage, overcurrent, sensor failure, etc.

16. Communication: Standard RS232, wave rate 115200, optional WIFI

17. Current input: (1-2) channels, (0~22)mA。

18. Switch input: dry contact, capable of detecting contact resistance.

19. Circuit power supply: DC24V/30mA, if mistakenly connected to the standard meter, it will not damage the standard meter.

20. Pressure interface: M20 * 1.5 internal thread quick connector.

21. Current/voltage interface: A standard banana shaped plug with a diameter of 4.

22. Discharge outlet: Inner diameter: Φ 6mm.

23. Power supply: -5 ℃ to 50 ℃.

24. Weight: 19kg.

25. Dimensions: 300 (height) * 530 (width) * 300 (depth) mm.

26. Automatic calibration software: optional.

27. External standard table: optional.


Standard configuration:

1 verification table

1 aluminum alloy box

2 sets of watch bar wires

2 muffled heads

1 set of 56 point calibration software

1 RS232 communication cable

7 connectors

2 filters

1 manual

1 certificate of conformity

1 calibration certificate (optional according to customer requirements)