Hubei Agilent E4446A Spectrum Analyzer 44G Sales Lease $r $n Technical Specifications Frequency 3 Hz to 44 GHz, External Mixers to 325 GHz Maximum Analysis Bandwidth 80 MHz Bandwidth Options Standard 10, 40, 80 MHz DANL -168 dBm at 1 GHz Phase offset at 10 kHz
Hubei Agilent E4446A spectrum analyzer 44G sales and leasing
Hubei Agilent E4446A spectrum analyzer 44G sales and leasing
performance
- +/-0.24 dB amplitude accuracy
- -Average noise level displayed at 155 dBm/Hz (DNAL)
- Phase noise at 10 kHz bias: -118 dBc/Hz
- 81 dB W-CDMA ACLR dynamic range
Analyze bandwidth
- 40 or 80 MHz analysis bandwidth supports capturing and measuring complex signals.
- -78 dB (rated value) third-order intermodulation
- 0.5 dB IF frequency response
- -78 dB (rated value) third-order intermodulation
flexibility
- The power kit can perform one click power measurement for more than 20 wireless standards. PSA power kit enables one click power measurement
description
E4440 PSA measures RF and microwave signals up to 26.5GHz.
View PSA High Bandwidth Digital Converter Video Demo
Main features:
For more features, please refer to the PSA series promotional materials
dynamic range
·-155dBm Display Average Noise Level (DANL)
·+17 dBm Third Order Intermodulation (TOI) (+19 dBm typical)
·-116 dBc/Hz phase noise (10 kHz bias) (-118 dBc/Hz typical)
degree
·± 0.62 dB amplitude accuracy (± 0.24 dB typical)
·± 0.38 dB frequency response (± 0.11 dB typical)
·± 0.07 dB logarithmic amplification linearity
speed
·Fast low-level parasitic search
·<30 ms fast ACP measurement
·50 measurement/second local update rate, 45 measurement/second remote measurement
Standard features:
·Fully digital IF with automatic range function
·Phase noise optimization
·Complete detector kit
·160 resolution bandwidth settings (10% step)
·2 dB Step Attenuator
·FFT and sweep frequency measurement mode
·Gate selection scanning frequency
·Single key power measurement
·Use built-in CISPR and MIL standard pre compatible EMI detectors and bandwidth for EMI measurement
Optional features:
·Built in preamplifier (option 1DS: 100 kHz -3 GHz; Option 110: 10 MHz -26.5 GHz)
·Easy to use built-in PSA series measuring keys
·Modulation analysis and linking to 89601A vector signal analysis software
·40 MHz or 80 MHz bandwidth digital converter
·325 GHz frequency range using external mixing
option
Get detailed information:View configuration guide
| Word demodulation measurement |
| E4440A-BAF |
W-CDMA measurement software, fixed license |
| E4440A-202 |
GSM/EDGE measurement software, fixed license |
| E4440A-B78 |
cdma2000 ® Measurement software, fixed license |
| E4440A-204 |
1xEV DO measurement software, fixed license |
| E4440A-BAC |
CDMaOne measurement software, fixed license |
| E4440A-BAE |
NADC/PDC measurement software, fixed license |
| E4440A-210 |
HSDPA/HSUPA personality measurement, fixed license |
| E4440A-214 |
1XEV-DV personality measurement, fixed license |
| E4440A-241 |
Flexible digital modulation analysis, fixed license |
| E4440A-217 |
WLAN measurement software, fixed license |
| E4440A-212 |
TD-SCDMA modulation analysis and measurement of personality, fixed license |
| E4440A-213 |
HSA/8PSK for TD-SCDMA modulation analysis and personality measurement, fixed license |
| |
| Digital demodulation hardware |
| E4440A-B7J |
Digital demodulation hardware |
| |
| software |
| E4440A-226 |
Phase noise measurement software, fixed license |
| E4440A-219 |
Noise factor measurement software, fixed license |
| E4440A-HB6 |
Prevent unauthorized firmware upgrades |
| E4440A-211 |
TD-SCDMA power measurement personality, fixed license |
| E4440A-266 |
8566/8568 Programming Code Compatibility Kit |
| E4440A-233 |
Measurement receiver measures personality, fixed license |
| E4440A-235 |
External Calibration Guide for Wide BW Digitizer, Fixed License |
| E4440A-215 |
External signal source control measurement software, fixed license |
| E4440A-HGT |
The door width is less than 10 uSec. |
| E4440A-HS1 |
Improve Security Level - Write to Protect User Files |
| E4440A-239 |
EMC measures personality, fixed license |
| |
| Input and output |
| E4440A-BAB |
APC 3.5 connector |
| E4440A-H70 |
70 MHz output |
| E4440A-HB2 |
21.4 MHz output |
| E4440A-H20 |
20 MHz, If the rear panel outputs |
| E4440A-HN9 |
Broadband IF output |
| E4440A-123 |
Switchable microwave pre selector bypass |
| E4440A-124 |
Y-axis video output |
| E4440A-HY7 |
Improve gain by 70 MHz output |
| E4440A-107 |
Audio input 100 kOhm |
| E4440A-111 |
USB device I/O interface |
| E4440A-117 |
Secure erase memory |
| |
| amplifier |
| E4440A-1DS |
RF internal preamplifier |
| E4440A-110 |
Built in RF/microwave preamplifier |
| |
| external mixing |
| E4440A-AYZ |
External frequency mixing |
| |
| Broadband IF |
| E4440A-122 |
Bandwidth digitizer, 80 MHz |
| E4440A-140 |
Bandwidth digitizer, 40 MHz |
| |
| calibration file |
| E4440A-UK6 |
Commercial calibration certificate containing test data |
| E4440A-A6J |
ANSI Z540-1-1994 校准 |
| E4440A-AMG |
Calibration+uncertainty+protection frequency band |
| |
| Customized solutions |
| E4440A-C01 |
RF connector color code |
| E4440A-HV5 |
Y-AXIS VIDEOOUTPUT is modified to 856x output level |
| |
| E4440A-23B |
CCITT filter for audio measurement, fixed license |
| |
| connection software |
| E4440A-230 |
BenchLink Network Remote Control Software |
Performance:+/-0.24 dB amplitude accuracy -155 dBm/Hz
Display average noise level (DNAL) Phase noise at 10 kHz bias: -118 dBc/Hz Phase noise at 10 kHz bias: -118 dBc/Hz 81 dB W-CDMA ACLR Dynamic range analysis bandwidth 40 or 80 MHz Analysis bandwidth supports capturing and measuring complex signals. View: -78 dB (rated) 3rd order intermodulation 0.5 dB IF frequency response -78 dB (rated) 3rd order intermodulation description Agilent E4445A is an instrument in our PSA series modern high-performance spectrum analyzer, used for measuring and monitoring complex RF and microwave signals up to 13.2 GHz. brand new! HSDPA/HUPA measuring components are brand new! Main features of built-in receiver: dynamic range -155 dBm display average noise level (DANL)+17 dBm third-order intermodulation (TOI) (+19 dBm typical) -116 dBc/Hz phase noise (10 kHz bias) (-118 dBc/Hz typical)
Main features:
dynamic range
*-166dBm Display Average Noise Level (DANL)
*+17dBm third-order intermodulation (TOI) (+19 dBm typical)
*-116dBc/Hz phase noise (10 kHz bias) (-118dBc/Hz typical)
accuracy
*± 0.62 dB amplitude accuracy (± 0.24 dB typical)
*± 0.38 dB frequency response (± 0.11 dB typical)
*± 0.07 dB logarithmic amplification linearity
Speed:
*Fast low-level parasitic search
*<30ms fast ACP measurement
*50 measurement/second local update rate, 45 measurement/second remote measurement
Standard features:
For more features and information, please refer to the PSA series manual
*Fully digital IF with automatic range function
*Phase noise optimization
*Complete detector kit
*160 resolution bandwidth settings (10% step)
*2dB step attenuator
*FFT and sweep frequency measurement mode
*Gate selection scanning frequency
*Complete set of single key power measurement
*Use built-in CISPR and MIL standard pre compatible EMI detectors and bandwidth for EMI measurement
Optional features:
*40MHz or 80MHz bandwidth digital converter
*Built in preamplifier (option 1DS: 100 kHz -3 GHz; Option 110: 10 MHz -6.7 GHz)
*Easy to use built-in PSA series measuring keys
40MHz or 80MHz bandwidth digital converter
Built in preamplifier (option 1DS: 100 kHz -3 GHz); Option 110: 10 MHz -6.7 GHz)
X Easy to use built-in PSA series measuring key
Modulation analysis and linking to 89601A vector signal analysis software