- Phone
-
Address
301 Lane, Xianghuang Road, Shanghai
Shanghai Meibang Fluid Control Equipment Co., Ltd
301 Lane, Xianghuang Road, Shanghai
OneHigh voltage electrostatic ion rod for circulating water in water processorsworking principle
The ion rod water treatment technology adopts pure physical methods to perform electric field polarization treatment on industrial and domestic water, which can effectively remove the widespread problems of scaling, bacterial and algal growth, and pipeline corrosion in various water systems,. Ionic rods change the physical structure of water molecules through the direct action of high-voltage electrostatic fields, so that the cations contained in water do not tend towards the reactor wall, thereby achieving the purpose of scale prevention. Due to the effect of electrostatic field, the binding between molecules can be disrupted in the scaling system, changing the crystal structure, promoting the looseness of hard scale, increasing the dipole distance of water, and improving the dissolution rate of scale, gradually peeling off and detaching the already formed scale, achieving the purpose of scale removal.
Water treated with static electricity obtains energy and generates reactive oxygen species, which form a highly corrosion-resistant oxide black film on the metal surface in a scale free system, reducing further corrosion of the metal. Reactive oxygen species also have strong bactericidal effects, effectively killing bacteria and algae while inhibiting their growth in circulating water bodies that continuously use ion rods.

IIHigh voltage electrostatic ion rod for circulating water in water processorsProduct features
◎ Scale removal and prevention, sterilization and algae removal, corrosion inhibition and anti-corrosion
◎ Adopting chips, stable performance, ensuring long-lasting effectiveness
◎ Using cable connectors to ensure smooth connection and reliable sealing performance to protect the control circuit
Corrosion by corrosive gases
◎ Safe to use, high-voltage silicon stack electrostatic field, but with microampere level current, will never harm personal safety

IIIHigh voltage electrostatic ion rod for circulating water in water processorsapplication field
Industrial circulating water, central air conditioning circulating water system, boilers, and various heat exchange heating systems
Central water supply pipeline, reverse osmosis and membrane treatment in the water industry, etc
◎ Landscape fountain, reservoir, breeding pool, swimming pool


4High voltage electrostatic ion rod for circulating water in water processorsSpecification and Selection Table
| Specification Model | Applicable pipe diameter (mm) | Flow rate (m³ | Applicable pool (m3) |
| ML-L-80I | 80 | 60 | |
| ML-L100I | 100 | 90 | |
| ML-L-125I | 125 | 150 | |
| ML-L-150I | 150 | 220 | 2 |
| ML-L-200I | 200 | 380 | 3 |
| ML-L750I | 250 or above | 600 | 6 |
ML-L750I type, with a processing capacity of 160-300m3/h for open circulating water and 350-600m3/h for closed circulating water in the same system
For example, if the main pipe diameter of the system is DN250 and the flow rate is 600m3/h, an open circulating water system should be equipped with two sets of ion rod water processors.
Increase the number of ion rod water processors as appropriate based on the processing water volume and operating conditions.
5High voltage electrostatic ion rod for circulating water in water processorsInstallation parameters
| Probe diameter | 30mm | input voltage | AC220/50Hz |
| Rod length | 420mm | output voltage | >DC7.5KV |
| Rod length | 550mm | output voltage | >DC10KV |
| Inner diameter of connecting screw | 70mm | power consumption | <10W |
| Teflon layer thickness | 40um | Adapt to water quality | ≤700mg/L(CaCO3)2 |
| wire length | 2800mm | Adapt to water temperature | ≤99℃ |
| service life | 10-15 years | execution standard | HG/3133-1998 |
VIHigh voltage electrostatic ion rod for circulating water in water processorsInstallation precautions
The diameter of the pipeline for installing the ion rod shall not be less than 80mm. The installation position is shown in the figure
The installation direction of the ion rod should be relative to the direction of water flow
The installation location should be at least 2 meters away from the motor or pump, and at least 5 meters away from the high-voltage transformer
The power supply should have a good grounding terminal, and the controller should be installed in a dry and ventilated place
Pay attention to the PTFE protective layer on the surface of the ion rod during installation, any damage will affect the effectiveness of use
The ion rod is equipped with a dedicated connecting nut seat, and attention should be paid to the forward and backward directions when welding. Pay attention to whether the screw threads match during assembly
A large diameter and high flow circulating water system should be installed in parallel with multiple channels to meet the required treatment requirements, as shown in the diagram