High temperature flowmeter

NegotiableUpdate on 06/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

For measuring high-temperature liquids and gases, a vortex flowmeter is usually selected when the temperature is above 250 degrees and below 330 degrees. Sometimes the temperature is higher than 330 degrees and even higher than 600 degrees. In this case, a differential pressure V-cone flowmeter is needed.

Product Details


High temperature flowmeterFor measuring high-temperature liquids and gases, high-temperature vortex flowmeters are usually chosen for temperatures above 250 degrees and below 330 degrees. Sometimes, temperatures above 330 degrees may also be moreAbove 600 degrees, a differential pressure V-cone flowmeter needs to be selected.

tallTemperature type flowmeterWhen selecting, it is necessary to collect fluid related parameters:

Fluid name, pipeline diameter, maximum and minimum flow rates, maximum and minimum pressures, maximum and minimum medium temperatures, installation pipeline material, and on-site operating conditions requirements.

High temperature flowmeterThe price is affected by changes in selection specifications, caliber, and configuration, and is not a fixed price product. It needs to be selected and quoted according to your working conditions.


High temperature flowmeter---High temperature vortex flowmeter

Measure high-temperature steam and gas, with temperatures above 250 ° C and below 330 ° C.

Common model: HVS-DG80F31P

Model annotation:Vortex FlowmeterThe medium is a high-temperature gas, DN80, The body material is 304 stainless steel, with a medium temperature of 330 ° C and a rated pressure of 1.6MPa; Pulse output, 24V power supply, matched with carbon steel installation flanges, bolts, nuts and other fasteners.

High temperature vortex flowmeters often adopt a split type.

高温型

(High temperature type)

分体式

(Split type voltage stabilization compensation)

Specification

Measurement medium: gas, liquid, vapor
The caliber specifications for flange card mounted calibers include 25, 32, 50, 80, 100, etc; Flange connection type caliber selection: 100, 150, 200, etc
Flow measurement range: Normal measurement flow velocity range, Reynolds number 1.5 × 104~4 × 106; Gas velocity of 5-50m/s; Liquid 0.5-7m/s
The normal measurement range for liquid and gas flow is shown in Table 2; The steam flow range is shown in Table 3 (link)Steam flow meter )
Measurement accuracy level 1.0/1.5
Temperature of the tested medium: normal temperature -25 ℃ -100 ℃;High temperature -25 ℃~250 ℃ -25 ℃~350 ℃
Output signal pulse voltage output signal high level 8-10V low level 0.7-1.3V
Pulse duty cycle of about 50%, transmission distance of 100m; pulse current remote transmission signal of 4-20mA, transmission distance of 1000m
Instrument operating environment temperature: -25 ℃~+55 ℃ humidity: 5-90% RH50 ℃
Material: stainless steel, aluminum alloy
Power supply DC24V or lithium battery 3.6V
Explosion proof grade intrinsic safety type iaIIbT3-T6
Protection level IP65


High temperature flowmeter~High temperature V-cone flowmeter

High temperature V-cone flow meters can be selected for high-temperature media with temperatures above 250 degrees Celsius, especially those with temperatures above 330 degrees Celsius.

When selecting and ordering high-temperature V-cone flow meters, users should first provide the following process parameters to the manufacturing enterprise:

1. Diameter of the pipeline (diameter * wall thickness)

2. Material of pipeline
3. The medium measured by the flowmeter
4. Working temperature of the tested medium
5. Working pressure of the tested medium (maximum pressure, minimum pressure, normal pressure)
6. The working flow rate of the tested medium (maximum flow rate, minimum flow rate, normal flow rate)
7. Viscosity of the measured medium

Note: The above parameters are the basis for detailed calculations by the manufacturer before production. Without these parameters, it is difficult to produce a V-cone flowmeter that meets user requirements. The manufacturer calculates the beta value and differential pressure value (range of differential pressure transmitter) of the V-cone flow sensor based on the above parameters provided by the user. These tasks are calculated and completed by professional engineers in the manufacturing plant.

High temperature V-cone flowmeterCommon model: HQZ-A200A3-1.0SRFHC

Model annotation: V-cone flowmeter, DN200, The measuring medium is: high-temperature steam, flange connection, the material of the body and V-cone are both 304 stainless steel, the medium temperature is 400 degrees, the rated pressure is 1.0MPa, the flange is used for pressure measurement, and high-temperature installation accessories are provided (one globe valve, one three valve group, condenser and condenser, and two pressure pipes).

A complete set of V-cone flowmeter includes: V-cone flow sensor, differential pressure transmitter, installation accessories, installation flanges and fasteners (multiple self equipped), flow integrator

高温型V锥流量计

高温型V锥流量计实际拍摄

High temperature V-coneflowMeterThe price is affected by changes in selection specifications, caliber, and configuration, and is not a fixed price product. It needs to be selected and quoted according to your working conditions

Configuration Description:

高温型V锥流量计配置文字介绍

高温型V锥流量计配置图解

Technical specifications

1. There are several structural forms of V-shaped cone flow meters, including direct welding, flange connection, square tube, clamp type, and non-standard customized. The scope of product supply is shown in the selection table.

2. Scope of use: Widely used for measuring various fluids such as oil, water, gas, and steam, especially for measuring high-temperature, high-pressure, and dirty media, which is significantly stronger than other instruments

3. Accuracy level: ± 0.5%

4. Repeatability: 0.1%

5. Work pressure: maximum 42MPa

6. Working temperature: -40~700C ° C

7. Environmental temperature: -40 to 80 ° C

8. Range ratio: usually 10:1, using a suitable differential pressure transmission can reach 60:1

9. Installation requirements for straight pipe section: front 3D straight pipe section, rear 1D straight pipe section

10. Applicable media: Almost applicable to all gas and liquid media

11. Nominal diameter: DN15~DN2000

12. Structural material materials: pipes, body flanges, and V-cones can provide multiple materials for users to choose from to meet the needs of different working conditions

13. Installation method: Multiple accessories can be provided for users to install, meeting the needs of various working conditions. It can be installed in any direction, regardless of the medium state

14. Explosion proof grade (differential pressure transmitter): explosion-proof, intrinsic safety, non explosion-proof options available (differential pressure transmitter)

15. Power supply (differential pressure transmitter): 12-24VDC

16. Output signal (differential pressure transmitter): 4-20mA or HART protocol


High temperature flow meters can also be selected as high-temperature orifice flow meters


After sales and warranty

Shanghai Shihong Instrument Co., LtdAll products supplied:

Provide free telephone consultation, guidance on installation and debugging services;

Negotiate on-site guidance for installation, debugging, and other matters, and only charge reasonable travel expenses;

Large quantities can provide free on-site guidance for installation and debugging.

Service Objective:No matter how long the product is used, as long as you find us, we will solve all your problems until you are satisfied. We believe that our years of practical experience in the flowmeter industry can bring you satisfactory services.