High temperature and low temperature constant temperature bath (external circulation)

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The external circulation low-temperature constant temperature bath is controlled by single-chip microprocessing and self-tuning PID regulation. Imported high-precision platinum resistance (Pt100) temperature measurement has high temperature control accuracy and low fluctuation; The external circulation low-temperature constant temperature bath adopts a fully enclosed compressor technology (for series below -40 ℃ or 30 liters, fully imported dual compressor cascade refrigeration technology and heat exchange system are used), with high refrigeration efficiency and low noise. The instrument works stably and reliably, with convenient and safe operation.

Product Details

DC SeriesHigh temperature and low temperature constant temperature bath (external circulation low temperature constant temperature bath)It can be applied to fields such as biotechnology, medicine, food, chemical engineering, metallurgy, chemical analysis, petroleum, etc., providing users with a controlled and temperature uniform constant field source. It is used by research institutes, universities, factory laboratories, and quality inspection departments to provide users with a cold and hot controlled, temperature uniform and constant liquid environment when working. It can be directly used for constant temperature testing or testing of test samples or produced products in the tank, and can be used for direct heating or cooling as an auxiliary heating or cooling temperature source, such as temperature control for reaction vessels, fully automatic synthesis instruments, extraction and condensation devices.

Application fields of high-temperature and low-temperature constant temperature bath:

1. Constant temperature field: sensor detection, constant temperature biochemical reactions, constant temperature material aging, etc.

2. Biochemical field: rotary evaporator, Abbe refractometer, polarimeter, atomic absorption spectroscopy ICP-MS 、ICP、 Nuclear magnetic resonance CCD、 Biological fermentation tanks, chemical reactors (synthesizers), etc.

3. Materials field: electron microscopy, X-ray diffraction, X-ray fluorescence, vacuum sputtering electroplating, vacuum coating machine, ICP etching, semiconductor equipment, fatigue testing machine, chemical deposition system, atomic deposition system, etc.

4. Physical and chemical fields: lasers, magnetic fields, molecular pumps, diffusion pumps, ion pumps, and materials fields.

DC-0506High temperature and low temperature constant temperature bath (external circulation low temperature constant temperature bath)Product Introduction

1. Adopting single-chip microprocessing control, self-tuning PID regulation, platinum resistance (Pt100) temperature measurement, high temperature control accuracy and low fluctuation;

2. Adopting a fully enclosed compressor (using dual compressor cascade refrigeration technology and heat exchange system for temperatures below -40 ℃ or 30 liter series), with high refrigeration efficiency and low noise; The instrument works stably and is easy to operate.

3. The foldable handles on both sides facilitate the transportation of instruments. The 20L and above series and low-temperature constant temperature baths below -40 ℃ use heavy-duty self-locking casters for easy movement.

4. Adopting integral foaming technology, it has good thermal insulation performance and reduces the loss of cooling capacity;

5. The circulating stirring design ensures that the liquid in the tank is evenly and smoothly dispersed in the internal circulation, and the heat exchange is smooth.

6. The flow rate of the low-temperature constant temperature bath stirring pump with a capacity of 20L or more is 10L/min, and the remaining 8L/min. The temperature fluctuation is ± 0.02 ℃, and the display resolution is 0.01 ℃.

DC-0506High temperature and low temperature constant temperature bath (external circulation low temperature constant temperature bath)Suitable for internal/external temperature control applications: The sample can be directly placed in an open bath to maintain a constant temperature, or it can be externally controlled to measure units that require constant temperature.

DC-0506High temperature and low temperature constant temperature bath (external circulation low temperature constant temperature bath)Features:

1. Adopting microcomputer temperature control PID regulation and self-tuning control technology, the temperature control accuracy reaches ± 0.02 ℃

2. Adopting a large frequency screen LCD display for a more intuitive understanding of the working status

3. Fully enclosed compressor refrigeration system, CFC free, fast cooling.

4. Temperature range: optional -50~100 ℃ (the medium can be pure water, ethylene glycol, alcohol, etc. according to the temperature range), or customized products can be designed and produced according to user requirements

5. Capacity range: 6L, 10L, 15L, 20L, 30L, customized products can also be designed and produced according to user requirements.

6. The body shell adopts anti-aging electrostatic spraying technology, and the platform, inner tank, mixing pump, etc. are made of SUS304 stainless steel material, with excellent workmanship;

7. The well crafted front panel and tabletop of the chassis, coupled with a humanized R-rounded design structure, can prevent operators from being accidentally injured by sharp edges.

8. Removable ventilation grille, convenient for cleaning the condenser of the refrigeration unit

9. Internal circulation function: Adopting a non heat centrifugal circulation pump to avoid the influence of traditional water pumps on the tank temperature field due to their own heat generation.

10. External circulation function: The circulation pump can circulate a constant temperature liquid and establish a second temperature field.

11. Low temperature constant temperature bath protection device:

1) Equipped with power-off protection function

2) Capable of setting upper and lower temperature limits

3) Temperature runaway protection and alarm function

4) The heating device has low water level anti dry burning and explosion-proof functions

5) Multiple protection functions for compressor overheating and overcurrent

6) There is a sensor open circuit display function.

DC-0506High temperature and low temperature constant temperature bath (external circulation low temperature constant temperature bath)Technical parameters:

Low temperature constant temperature bathTechnical parameters:

⇒ 6-liter series

Model Name

DC-0506

DC-1006

DC-2006

DC-3006

DC-4006

DC-6506

DC-8006

DC-0506W

Temperature range (℃)

-5~100

-10~100

-20~100

-30~100

-40~100

-65~100

-80~100

-5~100

Temperature fluctuation (℃)

± 0.02 (25 ℃, medium is water or alcohol)

Display resolution (℃)

0.01

Inner container size (L)

6

Opening size (mm)

150 x 150 x 150 (length x width x depth)

orΦ70

Pump circulation mode

Internal and external circulation

Pump flow rate (L/min)

8L/min

Control method

Microcomputer temperature control, self-tuningPIDadjust

temperature sensor

Platinum ResistancePt100

Cooling method

compressor

Secondary compressor

compressor

Operating Voltage

220VAC±10%50Hz

Total power(kw)

1.2

2.0

1.2

Overall dimensions(mm)

340×405×670

510×510×1100

430×400×400

prepare note

Rectangular stainless steel inner liner, stainless steel tabletop, displaying settings and measurements separately

⇒ 10 liter series

type number

DC-0510

DC-1010

DC-2010

DC-3010

DC-4010

Temperature range (℃)

-5100

-10100

-20100

-30100

-40100

Temperature fluctuation (℃)

± 0.02

temperature control

Microcomputer temperature controlPIDadjust

Display resolution (℃)

0.01

Inner tank capacity (L)

10

opening sizemm

215 × 170 × 150 (length)×wide×Deep)

Pump circulation mode

inside/outer loop

Pump flow rate(L/min

8

Cooling method

compression refrigeration

Operating Voltage

220VAC±10%50Hz

powerkw)

2

Overall dimensions(mm)

340×405 ×670

Remark

Rectangular stainless steel inner liner, stainless steel tabletop, displaying settings and measurements separately

⇒ 15 liter series

Model number

DC-0515

DC-1015

DC-2015

DC-3015

DC-4015

DC-6515

Temperature range (℃)

-5100

-10100

-20100

-30100

-40~100

-65~100

Temperature fluctuation (℃)

± 0.02

temperature control

Microcomputer temperature control and PID regulation

Display resolution (℃)

0.01

Inner tank capacity (L)

15

Opening size (mm)

215×175×200(Length x Width x Depth)

Pump circulation mode

Internal/External Circulation

Pump flow rate(L/min

10

Cooling method

compression refrigeration

Secondary compressor

Dimensions (mm)

375×455×740

450×550×900

650×520×1000

⇒ 20 liter series

type number

DC-0520

DC-1020

DC-2020

DC-3020

DC-4020

Temperature range (℃)

-5100

-10100

-20100

-30~100

-40~100

Temperature fluctuation (℃)

± 0.0225℃, medium is water or alcohol)

temperature control

Microcomputer temperature controlPIDadjust

Display resolution (℃)

0.01

Inner tank capacity (L)

20

Opening size(mm

190×230×250(Length x Width x Depth)

Pump circulation mode

Internal and external circulation

Pump flow rate(L/min

10

Control method

Microcomputer temperature control, PID regulation

temperature sensor

Pt100

Operating Voltage

220v±10% 50Hz

Cooling method

compression refrigeration

Total power(KW

3.0

Dimensions (mm)

510× 510 × 1100

⇒ 30 liter series

type number

DC-0530

DC-1030

DC-2030

DC-3030

DC-4030

Temperature range (℃)

-5-100

-10100

-20100

-30100

-40100

Temperature fluctuation (℃)

± 0.02

temperature control

Microcomputer temperature controlPIDadjust

Display accuracy (℃)

0.01

Inner tank capacity (L)

30

Opening size (mm)

270× 220 × 270 (Long)×wide×Deep)

Pump circulation mode

Internal/External Circulation

Pump flow rate(L/min

10

Cooling method

compression refrigeration

Working voltage (AC)

220V±10% 50HZ

Power (KW)

3.0

Dimensions (mm)

444×600×1100



High temperature and low temperature constant temperature bath
Work environment:
1. The constant temperature bath should be placed on a sturdy workbench;
2. No vibration;
3. The room temperature should be relatively stable and not fluctuate rapidly, otherwise it will affect the temperature control accuracy; The room temperature should be around 25 ℃ (-40 ℃, -65 ℃, -80 ℃ constant temperature bath). Excessive room temperature can affect compressor heat dissipation, reduce refrigeration efficiency, and easily cause malfunctions;
4. The constant temperature bath should be regularly maintained. If the cooling rate slows down after working for a period of time, the plastic mesh plate of the constant temperature bath should be removed and the dust on the compressor and heat dissipation plate should be cleaned.

High temperature and low temperature constant temperature bathOptional Function Guide:

1. Optional external PT100 temperature sensor, which can detect and control the temperature of the external system in real time during external circulation.

2. Optional built-in temperature control program with 1-30 segments, capable of automatic program temperature control and real-time display of the set temperature time program running status.

3. Optional RS232 or RS485 communication interface, easy to connect to the upper computer, with Modbus RTU communication protocol.

4. Optional design and installation of magnetic stirring system, which can directly perform magnetic stirring on liquid samples placed in beakers in the constant temperature bath working room, without the need for an external vertical mixer, reducing redundant operations.

5. Optional cooling coils built into the tank can be used to cool and control the exothermic reactions of the system.

6. Optional height adjustable immersion platform for easy adjustment of the liquid level of the immersed sample.

7. Low water level protection and alarm function

8. It can be optionally designed with a horizontal shape, featuring compact structure, lowered center of gravity, and stability.

高温低温恒温槽(外循环)

Description of optional temperature control function inside/outside the constant temperature bath

This sink has internal and external circulation functions (optional with external PT100 temperature sensor), which can conduct constant temperature experiments inside the sink and also establish a closed second temperature field externally. When used as a second temperature field, the internal and external temperature sensors behind the machine can be usedMeasure and control the temperature of the second temperature field.

High temperature and low temperature constant temperature bathUsage:

When conducting a constant temperature test in the sink, simply turn the temperature switch to the internal temperature.

When it is necessary to establish a second temperature field for use, connect the external temperature sensor equipped on this machine to the machine, first turn the temperature switch to the internal temperature, set the water tank temperature to the desired temperature, wait for the instrument to display a stable temperature for 10-20 minutes, then turn the temperature switch to the external temperature. At this time, the constant temperature bath can be controlled by a PID temperature control instrumentControl the temperature of the second temperature field.

Attention: Do not directly turn the temperature setting switch to the external temperature, in order to avoid accidents caused by the slow rise of the external temperature and the high temperature inside the constant temperature bath.

高温低温恒温槽(外循环)

1. External temperature sensor interface

2. Temperature switch

3. Fuse interface

4. power cord interface

高温低温恒温槽(外循环)

After-sales service

1 Efficient order processing, secure packaging, and timely delivery.

2 During the use of our company's products, we will provide technical service support ranging from technical consultation, parts supply to maintenance services.

3. All equipment sold by our company comes with a one-year warranty and lifetime maintenance. During the warranty period, replacement and repair of spare parts are provided (note: man-made faults or damages are not covered by the warranty).

4. The after-sales service team is composed of a team of production and R&D personnel who have undergone various technical trainings, with rich guidance experience, and can promptly and efficiently assist users in solving problems that arise during installation and use.

5 After-sales service/64167716

Selection Guide

this companyDCSeries low-temperature constant temperature bath(water bath)There are multiple specifications, and customers can choose products based on the temperature range and inner tank capacity:

temperature range()

-5

-10

-20

-30

-40

-65

-80

Inner container capacity(L)

3

6

10

15

20

30

this companyCHSeries constant temperature bath(Water bath, oil bath)There are various specifications available, and customers can choose products based on the temperature range and inner tank capacity

temperature range()

100

150

200

300

Inner container capacity(L)

6

15

Note: Considering safety factors, high temperatures are higher than100The models with a temperature of ℃ all adopt internal circulation (customers can customize separately if they have other requirements)

In addition, our company producesPerspective type constant temperature bathFour sided glass facilitates observation of changes in the tested sample; Our company can undertake customization of various specifications according to customer requirementsnon-standardThermostatic bath products, welcome customers to consult and purchase products.