-Working principle of Hash Amtax SC ammonia nitrogen online monitoring analyzer in the United States:
The Amtax SC ammonia nitrogen online monitoring instrument uses the ammonia sensitive electrode method for the determination of ammonia nitrogen.
-Application industry:
The Amtax SC ammonia nitrogen online monitor is suitable for measuring ammonia nitrogen in drinking water, surface water, industrial production process water, sewage treatment processes, and wastewater discharge outlets.
-Characteristics of Hash Amtax SC Ammonia Nitrogen Online Monitoring Analyzer Instrument:
The Amtax SC ammonia nitrogen online monitor uses the ammonia sensitive electrode method for ammonia nitrogen determination, with four range options and a wide measurement range.
The Amtax SC ammonia nitrogen online monitor does not require reaction reagents, and the electrode filling solution can be used for at least 3 months, with extremely low operating costs.
The lowest detection limit of Amtax SC ammonia nitrogen online monitor is 0.02mg/L, with high accuracy.
Built in plug and play fully functional digital controller with good scalability, easy to achieve integrated sampling, measurement, and data transmission, intelligent and reliable.
The Amtax SC ammonia nitrogen online monitoring device has automatic cleaning, calibration, and diagnosis functions, with minimal maintenance workload.
The Amtax SC ammonia nitrogen online monitor has a fast response speed and can adapt to the requirements of different types of water samples.
Advanced sampling preprocessing system is available for selection.
| Technical indicators of Hash Amtax SC ammonia nitrogen online monitoring analyzer in the United States | |
|---|---|
| Range (NH4-N) | 0.02 ~5.00 mg /L 0.05 ~ 20mg /L 1 ~ 100mg /L 10 ~ 1000mg /L |
| LoD | 0.02mg/L; 0.05mg/L; 1mg/L; 10mg/L; |
| accuracy | Within the measurement range of 0.02~5mg/L: 3%+0.02mg/L when ≤ 1mg/L; When>1mg/L, 5%+0.02mg/L; |
| Within the measurement range of 0.05~20mg/L: 3% ± 0.05mg/L; | |
| Within the measurement range of 1.0~100mg/L: 3% ± 1.0mg/L; | |
| Within the measurement range of 10-1000mg/L: 4.5% ± 10mg/L; | |
| reproducibility | 3%±0.02mg/L; 2%±0.05mg/L; 2%±1.0mg/L; 2%±10mg/L; |
| Response time (T90) | Within the range of 0.02~5mg/L: 0.02~0.2mg/L: 15min; 0.2~5mg/L:5min; |
| Within the range of 0.05~20, 1~100, 10~1000mg/L:<5 minutes; | |
| Measurement Interval | Adjustable from 5 to 120 minutes |
| Sample conditions | Temperature: 4-40 ℃, pH:5~9 |
| operation condition | Temperature: -20~45 ℃ Humidity: Relative humidity 95% Non condensing |
| Power requirements | 230VAc/50Hz or 115 VAc/50-60Hz |
| data transmission | SC1000 multi parameter universal controller with data cable or SC200 universal controller |
| Output via | Relay, current output, and bus interface of SC1000 multi parameter universal controller or SC200 universal controller |
| Shell characteristics | Meets the UV protection requirements of the American Standards Institute, with a lockable housing and a protection standard of IP65 |
| Carton size | 540 × 720 × 390 mm |
| Cable Length | 2 meters from the outer shell |
| Instrument weight | 35 kilograms (including reagents) |
| Sample filtration | Obtain continuous samples (approximately 500-1000mL/min) using either the Filterprobe sc (as described below) or FILTRAX, ultrafiltration, etc |
| Power supply power | Heat the hose with a filter probe of 5 or 10 meters using a 100 watt analyzer (transient peak power consumption: 1000 volt ampere) |
| Sample flow rate | Maximum 3 meters per second |
| Filtrate flow rate | At least 4 out of every 5 minutes reach 5 milliliters per minute |
| Carton size | 315 × 250 × 120 mm |
| ordering guide | |
|---|---|
| The standard configuration of AMTAX sc ammonia nitrogen analyzer includes: AMTAX sc ammonia nitrogen analyzer host, filter probe, installation accessories, operation manual, reagents, etc. The sc1000 or sc200 controller needs to be ordered separately | |
| 61570-00 | AMTAX sc ammonia nitrogen analyzer, 0.05-20mg/L, 220V; Including a filter probe with a 5-meter heating hose |
| 61571-00 | AMTAX sc ammonia nitrogen analyzer, 0.05-20mg/L, 220V; Including a filter probe with a 10 meter heating hose |
| 61576-00 | AMTAX sc ammonia nitrogen analyzer, 1-100mg/L, 220V; Including a filter probe with a 5-meter heating hose |
| 61577-00 | AMTAX sc ammonia nitrogen analyzer, 1-100mg/L, 220V; Including a filter probe with a 10 meter heating hose |
| 61582-00 | AMTAX sc ammonia nitrogen analyzer, 10-1000mg/L, 220V; Including a filter probe with a 5-meter heating hose |
| 61583-00 | AMTAX sc ammonia nitrogen analyzer, 10-100mg/L, 220V; Including a filter probe with a 10 meter heating hose |
| AMTAX sc ammonia nitrogen analyzer host (excluding controller and filter probe) | |
| 61574-00 | AMTAX sc ammonia nitrogen analyzer host, 0.05-20mg/L, single channel continuous injection, 220 volts, |
| 61580-00 | AMTAX sc ammonia nitrogen analyzer host, 1-100mg/L, single channel continuous injection, 220V, |
| 61586-00 | AMTAX sc ammonia nitrogen analyzer host, 10-1000mg/L, single channel continuous injection, 220V, |
| If you need an AMTAX sc dual channel ammonia nitrogen analyzer, please contact Hash Company's offices in China | |
| Single Amtax sc (excluding Filter Probe sc) | |
| 90091-00 | Amtax SC ammonia nitrogen analyzer 0.02-5 mg/L, 115-230 Vac; Continuous single channel sampling |
| 90092-00 | Amtax SC ammonia nitrogen analyzer 0.02-5 mg/L, 115-230 Vac; Continuous dual channel sampling |
| Amtax SC Ammonia Nitrogen Analyzer (including Filter Probe SC) | |
| 90089-00 | Amtax SC ammonia nitrogen analyzer 0.02-5 mg/L, 230 Vac; Including 5-meter filtration probe with heating tube |
| 90090-00 | Amtax SC ammonia nitrogen analyzer 0.02-5 mg/L, 230 Vac; Including a 10 meter filtration probe with heating tube |
| Sample filtration | |
| LXV429.99.01000 | Filterprobe sc, 5-meter heating hose, 220V/50Hz |
| LXV429.99.02000 | Filterprobe sc, 10 meter heating hose, 220V/50Hz |
| Installation accessories | |
| LZY285 | The rail type installation component is used for the installation of AMTAX sc ammonia nitrogen analyzer with sc1000 controller |
| LZY316 | The rail type installation component is used for the installation of AMTAX sc ammonia nitrogen analyzer without sc1000 controller |
| LZY286 | The bracket type installation component is used for the installation of AMTAX sc ammonia nitrogen analyzer with sc1000 controller |
| LZY287 | The bracket type installation component is used for the installation of AMTAX sc ammonia nitrogen analyzer without sc1000 controller |
| LZY714.99.42020 | Edge type installation components are used for the installation of Filter probe sc |
| LZX414.00.60000 | The rail type installation component is used for the installation of the Filter probe sc |
| reagent | |
| 28941-54 | 1 mg/L NH4-N ammonia nitrogen standard solution, 2000mL |
| 28943-54 | 10 mg/L NH4-N ammonia nitrogen standard solution, 2000mL |
| 28258-54 | 50 mg/L NH4-N ammonia nitrogen standard solution, 2000mL |
| 28259-54 | 500 mg/L NH4-N ammonia nitrogen standard solution, 2000mL |
| 28944-52 | AMTAX sc reagent, 2500 mL |
| 61825-00 | AMTAX sc electrolyte, 11 mL |
| 28942-46 | AMTAX sc cleaning solution, 250 mL |
| 2514654 | 0.5 mg/L NH4-N standard solution, 2000 ML |
| 2514754 | 2.5 mg/L NH4-N standard solution, 2000 ML |
| 2955300 | Electrode set, including electrolyte and membrane cap (for one year of use) |
| Replaceable parts | |
| LZY069 | Ammonia nitrogen electrode for AMTAX sc analyzer |
| LZY181 | Air pump head for AMTAX sc analyzer |
| LZY140 | Filter probe sc uses filter membrane components |
| LQV155.99.00002 | Power box, without power connection cable, used when Amtax sc and sc200 are connected |