Hanging pipe rain deviceTechnical specifications
|
model |
BL-04 |
BL-06 |
BL-08 |
BL-10 |
BL-12 |
|
|
Swing radius: M |
0.4M |
0.6M |
0.8M |
1M |
1.2M |
|
|
performance metrics |
Pipe swing amplitude |
± 45 °, ± 60 °, ± 90 °, ± 180 ° (theoretical values) |
||||
|
hole spacing |
50mm |
|||||
|
Spray hole |
φ0.4mm |
|||||
|
Rainwater pressure |
80~100pcs |
|||||
|
Test bench diameter |
Auxiliary test bench with a diameter of 600mm and a diameter of 400mm |
|||||
|
Test bench speed |
1r/min (optional for stepless speed regulation) |
|||||
|
control system |
controller |
Imported FM frequency converter |
||||
|
Water pressure control |
flow meter |
|||||
|
water supply system |
Water storage tank, booster pump |
|||||
|
Standard Configuration |
Several nozzles and needles |
|||||
The rain resistance performance of the equipment under rain conditions is IPX3-4 level
An instrument used to measure the rainproof performance level of equipment under different spraying angles, rated speeds and times, and different spraying pressures according to different usage conditions.
This instrument consists of two main parts: a swing tube section and a middle turntable.
Test angle: ± 60 °± 180 °
Swing tube radius: R600, R1000mm two models
Hanging pipe rain deviceProduct Structure and Performance Analysis
structural composition
It mainly consists of five parts
① Main transmission part: synchronous reduction motor (with brake)+synchronous belt drive
② Swing tube assembly: Swing tube radius ranges from 200 to 1600mm; Each level is 200mm. The number of spray holes and nozzle diameter shall be in accordance with the standard. (Comes standard with 2 pieces)
③ Rotary table assembly: DC reduction motor+worm gear transmission, one rotation per minute.
④ Control cabinet assembly: The large touch screen controls the normal operation of the equipment. And the control cabinet can freely adjust the angle.
⑤ Waterway section: A complete pressure and flow regulation system is composed of a filter, pressure regulating valve, solenoid valve, flow regulating valve, conversion valve, and flow meter. Two sets of flow meters ensure flow display that meets different standards.