1Handheld transformer DC resistance testersummarize
The transformer DC resistance tester is a new generation of rapid testing equipment developed by the company to measure the DC resistance of transformers, mutual inductors, generators, motors, switch contacts, splitters, and line wires.
IIHandheld transformer DC resistance testerFeatures
The instrument is powered by an internal lithium battery, which solves the problem of being unable to test on site due to the lack of working power supply;
The testing process is controlled by a microcomputer, which automatically completes self calibration, stable current judgment, data processing, and resistance display;
The longitudinal test of the DC resistance of the on load tap changer transformer can be completed in one start-up test operation;
Equipped with reverse potential protection, overheating protection, discharge alarm and other functions;
It has the characteristics of easy operation, high accuracy, anti-interference, shock resistance, and easy portability;
Equipped with temperature conversion function for testing resistance, it is convenient to compare with the resistance data of the test sample;
Adopting a 5-inch 800 * 480 high brightness LCD display with a brightness of up to 900nit, it is clearly visible under sunlight;
Built in large capacity non-volatile memory, capable of storing 500 sets of measurement data, and can be imported into a USB drive for storage;
Built in high-precision real-time clock function: capable of date and time calibration;
Built in 4400mAh rechargeable lithium battery, testing time can reach 4-8 hours;
Suitable for rapid measurement of DC resistance of transformers with voltage levels of 35kV and below.

IIIHandheld transformer DC resistance testerTechnical Specifications
Output current 10A, 3A, 1A, 300mA, 100mA, 5mA
Measurement range 10A: 100 μ Ω~ 200m Ω
3A: 10mΩ~2Ω
1A: 30mΩ~6Ω
300mA:100mΩ~20Ω
100mA:300mΩ~60Ω
5mA: 30Ω~60kΩ
Resolution 0.1 μ Ω
Measurement accuracy ± (0.2% reading+2 words)
Dimensions 252mm × 172mm × 81mm
Instrument weight 1.8kg
4Handheld transformer DC resistance testerTerms of Use
Environmental temperature -10 ℃~50 ℃
Environmental humidity ≤ 85% RH
Suitable for power input AC 220V/50Hz
Adapted power output DC 12.6V/2000mA
5Handheld transformer DC resistance testerPanel Introduction

Figure 5.1
①. U+, U -: voltage input terminal; I+, I -: Current output terminal.
②. LCD screen: used to display various operation and measurement data.
③. Keyboard: Used for various operations.
④. Charging port: Connect the built-in external charger (charging limit voltage DC12.6V).
⑤. USB interface: used to connect to a dedicated USB interface.
VIHandheld transformer DC resistance testerInstrument wiring
Test the I+and U +、U-、 The terminal and test sample are connected using the four terminal method shown in Figure 6.1, making the test wiring simple and convenient.

7Handheld transformer DC resistance testerOperation instructions
7.1 When the instrument is connected to the test line as required, turn on the power switch, and the LCD displays the main menu, as shown in the following figure

7.2 Start testing
In the main menu interface, press

On the parameter setting interface for transformer DC resistance test, press<>,<>or
Among them, the test winding can choose two types of test windings: high voltage and low voltage.
Test phase - refers to the phase to be tested;
预置 A-O/B-O/C-O/A-B/B-C/C-A/a-o/b-o/c-o/a-b/b-c/c-a。
Tap gear - selectable from 1 to 9 tap gears.
Winding Material - Two types of winding materials can be selected, including copper and aluminum.
Test temperature - the temperature at which the current test sample is being tested.
Converted temperature - the temperature that the standard needs to convert.
Test current -6 levels of test current can be selected, including 10A, 3A, 1A, 300mA, 100mA, 5mA, etc.
Sample number - refers to the number used to distinguish different tested products for easy retrieval and technical management in historical records.
When the parameters are modified to meet the experimental requirements, press the<>key to enter the measurement mode, and the LCD will display the following prompt:

After the test is completed, press<8>or<F2>Key for storing experimental data; Press directly without any operation<:>Press the key and wait for the discharge to complete before returning toParameter setting for transformer DC resistance testInterface.
7.3 Historical Records
atMain MenuPress down

In the history interface, press the<>and<>keys to select the history records to be queried.
In the history interface, press the<>key to switch between displaying experimental parameters and experimental data.
On the history interface, simultaneously press
In the history interface, press
7.4 Date and Time Setting
Press under the main menu

In the date and time setting interface, press the<'>and<'>keys to select the corresponding setting bit, and press the<">and<'>keys to modify the data of the corresponding setting bit. After modifying to the desired date and time, press the<8>key to save the corresponding settings and return to the main menu.
7.5 Backlight shutdown settings
Press the<>key in the main menu to enter the backlight shutdown setting interface, and the LCD display is shown in the following figure:

In the backlight shutdown settings interface, press
7.6 Instrument Calibration Settings
Press under the main menu
8Handheld transformer DC resistance testerPrecautions
The instrument design has a back electromotive force protection function, and during use, it is still necessary to follow the following steps one by one to ensure the personal safety of the instrument and testing personnel.
8.1 Before using this instrument, be sure to read this manual carefully.
8.2 The operator of the instrument should have general knowledge of using electrical equipment or instruments.
8.3 This instrument can be used both indoors and outdoors, but should be kept away from places such as rain, corrosive gases, excessive dust, high temperatures, and direct sunlight.
8.4 Maintenance, care, and adjustment of instruments should be carried out by professionals.
When measuring an unloaded voltage regulating transformer, be sure to wait for the discharge indicator alarm sound to stop before switching the tap gear.
During the testing process, it is prohibited to move the test clamp and power supply line.
After completing the 8.7 test, be sure to exit the testing state first and then remove the testing line.
8.8 Please use the built-in testing cable of the instrument to ensure testing accuracy and protect the internal power supply of the instrument.
8.9 The instrument enters standby mode after 1 minute without operation and automatically shuts down after 10 minutes (default setting).