1Handheld fully automatic transformer ratio testerProduct Overview
In the production process of semi-finished and finished power transformers, before the newly installed transformers are put into operation, according to the preventive testing regulations of the Ministry of Electric Power of China, it is required to regularly conduct turns ratio or voltage ratio tests on the operating transformers.
In response to this, our company has designed and developed a new generation of handheld transformer ratio tester, which is suitable for measuring ratios from distribution transformers to main transformers, Z-type transformers, and PT transformers. Compared with traditional electric bridges, all tap points of the main transformer can be tested with one wiring, greatly reducing the labor intensity of on-site testers.
IIHandheld fully automatic transformer ratio testerFeatures
The measurement range is wide, and the maximum transformation ratio test can reach 10000;
Built in three-phase digital power supply to improve testing stability;
The longitudinal testing of the transformation ratio of on load tap changers can be completed in one start-up test operation;
L has the function of testing transformers with T-shaped connections;
L has the functions of blind measurement of transformation ratio and group testing;
L has high and low voltage reverse connection protection and short circuit protection functions;
It has the characteristics of easy operation, high accuracy, anti-interference, shock resistance, and easy portability;
Adopting a 5-inch 800 * 480 high brightness LCD display with a brightness of up to 900nit, it is clearly visible under sunlight;
Equipped with a large capacity non-volatile memory, it can store 200 sets of measurement data and can be imported into a USB drive for storage;
Built in high-precision real-time clock function: capable of date and time calibration;
Built in 4400mAh large capacity imported lithium battery, suitable for long-term on-site testing and use.
IIIHandheld fully automatic transformer ratio testerTechnical Specifications
measure voltage 48VAC
measurement range 0.9~10000
part distinguish rate 0.0001(Min)
accurate indeed degree 0.2 level (0.9~5000)
Level 0.5 (5001)~10000)
Overall dimensions 252mm×172mm×81mm
Instrument weight 1.7kg
4Handheld fully automatic transformer ratio testerTerms of Use
ring realm Wen degree -10℃~50℃
ring realm wet degree ≤85%RH
Adapt to power input AC 220V/50Hz
Adapt power output DC 12.6V/2000mA
Charging limit voltage DC12.6V
electricity pool Rong quantity 4400mAh/55.4Wh
5Handheld fully automatic transformer ratio testerPanel Introduction

picture5.1
①.tall press side:Instrument power supplyoutput terminal,Connect the high voltage side of the test sample;
low press side:Instrument signalInput terminal post,Connect the low voltage side of the test sample;
pick up land pillarInstrument safety protection groundingpillar.
②. LCD screen: used to display various operation and measurement data.
③. Keyboard: Used for various operations.
④. Charging port: Connect the built-in external charger (charging limit voltage DC)12.6V)。
⑤.USB portUsed to connect to dedicated interfaces for USB drives.
VIHandheld fully automatic transformer ratio testerInstrument wiring
six point one threephasetransformertransformation ratioexperimentWiring as shown in the diagram below6.1shown,And connect the grounding wire as required:

picture6.Typical wiring method of three-phase transformer
6.2singlephaseTransformer(PT)transformation ratioexperimentWiring as shown in the diagram below6.2shown,And connect the grounding wire as required: