Overview
In the production process of semi-finished and finished power transformers, before the newly installed transformer is put into operation and according to the preventive testing regulations of the Ministry of Electric Power, it is required to conduct turns ratio or voltage ratio tests on the operating transformer. This can check the correctness of the turns ratio of the transformer, the condition of the tap changer, whether the transformer is short circuited between turns, and whether the transformer can operate in parallel. The traditional variable ratio bridge reading is not intuitive and can only be measured phase by phase for conversion. The XXG ratio tester overcomes the shortcomings of traditional ratio bridge testing, with simple and intuitive operation. It uses a three-phase precision inverter power supply for fast testing and high accuracy.
Two functional features
1. The instrument adopts a three-phase precision inverter power supply internally, which eliminates the harmonic influence of the mains voltage during measurement and makes the measurement more accurate.
2. Using three-phase output voltage to improve testing speed, it can measure phase to phase angle and also measure transformers with neutral points. It can automatically identify wiring groups 0-11. For rectifier transformers with multiple windings for low voltage measurement, the low voltage side can measure the transformation ratio and angle deviation of 7.5 ° without disconnecting the wires.
3. Suitable for a wide range of transformer types, especially for measuring Z-type transformers, rectifier transformers, grounding transformers, electric furnace transformers, phase-shifting transformers, Scott transformers, inverse Scott transformers, and other transformers.
4. It has high and low voltage reverse protection, transformer turn to turn short circuit protection, tap changer failure protection, output full short circuit protection, and increases instrument stability.
5. After inputting the rated parameters, the transformer transformation ratio, error value, and tap changer tap position can be automatically measured. Especially for tap changers with asymmetric tap changers, the accurate position of the transformer tap changer can also be accurately measured, up to 99 tap changer positions can be measured.
6. Seven inch high brightness touch color LCD, clear display under strong light, full touch screen operation, free switching between Chinese and English
7. The instrument can be connected to an external printer to print measurement data, making it convenient for paperless office (optional)
8. Adopting a multifunctional engineering plastic box that is cold resistant, temperature resistant, sealed, waterproof, and shockproof, it is convenient for field testing.
Three technical parameters
1. Test range: Variable ratio value -0.9 to 10000 degrees -0 to 360 degrees
2. Ratio accuracy: ± 0.1%+2 words (0.9-500)
± 0.2%+2 characters (501-2000)
± 0.5%+2 characters (2001-10000)
3. Angle accuracy: ± 0.2 °
4. Output voltage: automatically adjusted according to the load
5. Resolution: Ratio - minimum 0.0001, angle -0.01 °
6. Working power supply: battery powered
7. Environmental temperature: -10 ℃ to 40 ℃
8. Relative humidity: ≤ 85%, no condensation
9. Test line length: 13 meters
10. Dimensions: Host 252 * 160 * 65 (mm) Outer box: 425 * 335 * 210 (mm)
11. Weight: Host 2KG Outer box: 8KG (including host)
12. Test line length: Standard 13 meter length can be customized