Welcome Customer !

Membership

Help

Shanghai Pumin Industrial Automation Equipment Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Pumin Industrial Automation Equipment Co., Ltd

  • E-mail

  • Phone

  • Address

    Room 726, Building 2, No. 55 Meisheng Road, Pudong New Area Free Trade Zone, Shanghai

Contact Now

HYDAC temperature sensor TFP104-000 brand in stock

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

HYDAC Hedeke Temperature Sensor TFP104-000 Brand Spot $r $n Shanghai Pumin Industrial Automation Equipment Co., Ltd. specializes in the sales of imported spare parts from Europe and America. The company has its own offices in Germany and the United States, and the manufacturer purchases directly from the source. The price is more advantageous in the market. Brands with fast quotes: REXROTH Rexroth, ATOS,MOOG,festo, Yiboroebro, WEBTEC Germany ODE, SAMSON Samson, HYDAC Hedec, Baluff Baruff, PARKER Parker, BURKERT Baode

Product Details

HYDAC temperature sensor TFP104-000 brand in stock

Shanghai Pumin Industrial Automation Equipment Co., Ltd. specializes in the sales of imported spare parts from Europe and America. The company has its own offices in Germany and the United States, where manufacturers purchase directly from first-hand sources and prices are more advantageous in the market.

Fast quoting brand: REXROTH Rexroth, ATOS,MOOG,festo, Yiboroebro, WEBTEC Germany ODE, SAMSON Samson, HYDAC Hedec, Baluff Baruff, PARKER Parker, BURKERT Baode, IFM, P+F, ASCO solenoid valve, MAC solenoid valve Megger, and other common and unfamiliar brands in Europe and America.


1. Pressure switch/sensor

Mechanical: Using elastic elements such as diaphragms, bellows, or pistons to convert pressure into mechanical displacement, pushing the micro switch contacts to move and achieve on-off control. No power supply required, suitable for explosion-proof environments.

Electronic: The pressure is converted into an electrical signal through strain gauges or capacitive sensors. After amplification and analog-to-digital conversion, the MCU determines whether it has reached the set threshold and outputs a switch value or analog signal (such as 4-20mA).

Typical applications: hydraulic system pressure monitoring, safety protection, pump start stop control.

2. Overflow valve

Pilot operated relief valve: The main valve core pressure difference is controlled by the pilot valve. When the system pressure exceeds the set value (usually 10%~20% higher), the main valve opens and excess oil overflows back into the oil tank, maintaining a constant pump outlet pressure and having overload protection function.

Direct acting relief valve: suitable for low-pressure and low flow applications, with a simple structure but poor pressure stability.

HYDAC temperature sensor TFP104-000 brand in stock

3. Flow switch

Target type (baffle type): Fluid impacts the baffle to generate displacement, triggering the micro switch; Suitable for large diameter, high viscosity fluids with slow response (100-300ms).

Thermal conductivity type: detects flow rate through the temperature difference between the heating element and the fluid, with no moving parts and fast response (<50ms), suitable for low flow monitoring.

Turbo type: The fluid drives the turbine to rotate, and the magneto electric sensor converts the speed into a pulse signal with high accuracy (± 1% FS). The fluid needs to be cleaned.

4. Backwash filter

When the pressure difference between the inside and outside of the filter element reaches the preset value, the cleaning program is automatically started: the drain valve is opened, and the motor drives the stainless steel brush to spiral along the filter screen, using the pressure difference to remove impurities and maintain continuous operation of the system throughout the process.

5. Liquid level sensor (such as ENS series)

Adopting capacitive or inductive non-contact sensing, sensing liquid level through changes in dielectric constant of the medium, without mechanical wear, suitable for liquids such as oil and water.


The regular models of HYDAC solenoid valves are as follows:

WS08Z-01E-C-N-24DG

WS08C-01-C-N-24DG

WS10Y-M-01-C-N-24DC

WS16YR-01M-C-N

WS10ZR-01-C-N-24DG

WS10Z-01-C-N-24-DG

WS10VR-01-C-N-24DG

WS08YR-01-C-N-24DN

WS10W-01-C-N-24DG

WS08Z-01M-C-N

WS08Y-01M-C-N-24DG

WS10ZR-01-C-N-24DG

WS08W-01-C-N-24DG

WS10W-01M-C-N-24DG

WS16Z-01-C-N-24DG

HYDAC pressure sensor HDA3840-A-250-124

HYDAC pressure sensor HDA3840-A-350-124

HYDAC pressure sensor HDA3840-A-600-124

HYDAC pressure sensor HDA3840-E-250-124

HYDAC pressure sensor HDA3840-E-350-124

HYDAC Hedec Pressure Sensor HDA3840-E-600-124

HYDAC pressure sensor HDA3844-A-006-000

HYDAC pressure sensor HDA3844-A-016-000

HYDAC pressure sensor HDA3844-A-060-000

HYDAC pressure sensor HDA3844-A-100-000

HYDAC pressure sensor EDS1791-N-016-000

HYDAC pressure sensor EDS1791-N-040-000

HYDAC pressure sensor EDS1791-N-100-000

HYDAC pressure sensor EDS1791-N-250-000

HYDAC pressure sensor EDS1791-N-400-000

HYDAC pressure sensor EDS1791-N-600-000


For more product information, please click:Shanghai Pumin Industrial Automation Equipment Co., Ltd