-Measurement principle of HMA-TMN heavy metal total manganese online analyzer:
The instrument uses colorimetric spectrophotometry for detection. The sample is first added with a digestion reagent and then pumped to a high-temperature digestion unit for high-temperature digestion. The total manganese in the sample is dissolved into divalent manganese ions. The divalent manganese ions of the sample react with formaldehyde oxime in a slightly alkaline solution, forming a brown colored complex at a wavelength of 470nm for spectrophotometric determination. The concentration of the analyzed sample is determined based on the initial color of the sample and the degree of color change after adding a color developer.
-Typical applications:
Online monitoring of total manganese in surface water, industrial wastewater (such as electrolytic manganese wastewater), and sewage plant inlet and outlet
-HMA-TMN Heavy Metal Total Manganese Online Analyzer Instrument Features:
Low waste liquid. The amount of waste liquid is only 1.8L/month
Low reagent consumption. No need to replace reagents for one month
● Automatic range, automatic dilution. Simultaneously possessing low range and high range modes
● Automatic backwash sample filter, automatically cleaned before and after each test
● Automatic calibration
5.7 "color LCD touch screen
● Chinese menu
| Technical indicators of HMA-TMN online analyzer for heavy metal total manganese | |
|---|---|
| Measurement method: | colorimetry |
| Measurement range: | 0.1~5 (low), 0.5~20mg/L (high) |
| Detection limit: | 0.05mg/l |
| Accuracy: | ±3%F.S |
| Repeatability: | ±3%F.S |
| Zero drift: | ±5%F.S |
| Measurement time: | 50min |
| Automatic calibration cycle: | Closed, 1 day, 2 days... 7 days optional |
| Maximum reagent dosage: | 4.5L/month |
| Sample flow rate: | 1~3L/min, Take 50mL each time for measurement |
| Sample temperature range: | 10-40℃ |
| Signal output: | 4-20mA/RS232/RS485 |
| Installation environment: | Indoor installation |
| Power supply: | AC220V±10%,50Hz |
| Dimensions (height x depth x width): | 900 × 255 × 600mm (analyzer body) |
| Weight: | 60kg (without reagents) |
| ordering guide | |
|---|---|
| HMA-TMN total manganese online analyzer, standard configuration includes: host, reagent bottle, installation accessories, operation manual, and detection report. | |
| HMA-TMN | Total Manganese Heavy Metal Online Analyzer |
| Accessories Information | |
|---|---|
| 7321530K | Pure water tank (including liquid level sensor) |
| 7321540K | Waste liquid tank (including liquid level sensor) |