HIC anti hydrogen induced cracking hydrogen sulfide corrosion test device

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

HIC anti hydrogen induced cracking hydrogen sulfide corrosion test device $r $nGB/T 8650-2015 pipeline steel and pressure vessel steel anti hydrogen induced cracking evaluation method $r $nGB/T20972 "Materials for use in hydrogen sulfide containing environments in oil and gas extraction in the petroleum and natural gas industry"

Product Details

HIC anti hydrogen induced cracking hydrogen sulfide corrosion test deviceBasic Parameters


specification

name

H2S-2000

Reactor capacity

2300 ml

external dimensions

Φ140*150 mm

All steel fume hood (anti-corrosion)

850*1200*2350 mm

Gas cylinder cabinet(4ps)

1200*400*1100 mm

Filter sedimentation tank

800*800*800 mm

Spray tower (optional)

Φ500*1000mm

Gas emission outlet

Φ40 mm

performance

2.1.Test environment conditions

The ambient temperature is+25℃, relative humidity ≤85%

2.2.test method

GB/T 8650-2015 Evaluation Method for Hydrogen Induced Cracking Resistance of Pipeline Steel and Pressure Vessel Steel

GB/T20972The Oil and Gas Industry Materials used in environments containing hydrogen sulfide in oil and gas extraction

2.3.Temperature range of the test chamber

24℃±3℃

2.4.Standard quantitative pump flow range

Nitrogen:0300Ml/min accuracy 0.1ml

hydrogen sulfide:0-300ml/minprecision0.1ml

2.5.Leakage concentration probe detection range

0-10ppmThere are two standard configurations, one designed inside the gas cylinder cabinet and the other designed to be linked with the touch screen in the ventilation area. Once a leak is detected, the equipment will immediately stop working and trigger an alarm. The leakage alarm value0.1-1ppm adjustable)

2.6.Concentration control method

Accurate import of quality and traffic

2.7.Gas filtration method

Bubble neutralization filtration+Activated carbon adsorption treatment

3. Structural Introduction

3.1.material

Reaction kettle:Made of transparent acrylic, pressure resistant0.2MPa;

Link pipeline:Teflon material;

fume hood:Steel plate spraying (anti-corrosion coating)

trap:glass;

beaker:glass;

Waste disposal device:Transparent acrylic board

3.2.Location of thermometer

located inNear the equipment, the temperature near the reaction kettle can be continuously recorded

3.3.seal

Fluororubber sealing strip sealing, screw connection;

3.4.intake method

Steel cylinder type

3.5.Exhaust gas interface

φ40mm

3.6.Composition of exhaust gas

Weak alkaline high humidity gas, harmless to the five toxins,conform toGB16297-1996Industrial gas emission standards

3.7.Device Type

The inside of the reaction vessel is under positive pressure, with a pressure<0.1MPa(Optional anti-corrosion pressure detection system, once overpressure occurs, the equipment will shut down and emit a buzzing sound).

3.8.Leakage alarm device

becauseThe gas used in the experiment is hydrogen sulfide, which is toxic, so this equipment is designed with two setsLeakage alarm deviceOne of themLocated inside the gas safety cabinet,Another design is inside the fume hoodOnce there is a leak, an automatic sound and light alarm will be triggered, and the indoor air filter will be activated. The fan inside the air filter will start to extract air from the inside of the steel cylinder cabinet for replacement, and filter it before discharge until the monitoring probe cannot detect any corrosive gas inside. The machine will shut down to ensure the safety of the user.

3.9.Gas Cabinet

4PSGas cylinder cabinet, can be placed4bottle8LThe gas cylinder

3.10.waste discharge device

A waste discharge device is designed at the end of the internal process, mainly for configuring alkaline solution. The gas is bubbled by the alkaline solution and then adsorbed by activated carbon before being discharged into the factory's waste gas pipeline (if there is no waste gas pipeline in the factory, an additional waste gas treatment tower can be installed, and after three-stage filtration, it can be discharged outdoors)

3.11.intake method

The air intake of this device adopts the method of mass flow introduction, as shown in the attached test process for details

3.12.Control Panel

Programmable corrosion gas specific controller, power switch, paperless recorder

Corrosion gas controller

The temperature and humidity control instruments are imported7.0-inch color touch screen programmable controller, with a large screen, easy operation, and easy program editing,beltR232communication port;

1. Accuracy:0.1 ℃ (display range);

2. Resolution:±0.1℃;

3. Temperature sensor:PT100 platinum resistance thermometer;

4. Control mode: thermal balance temperature and humidity control mode;

5. Temperature and humidity control adoptsCoordination control of the P.I.D+S.S.R system on the same channel;

6. It has the function of automatic calculation, which can immediately correct the temperature and humidity change conditions, making temperature and humidity control more accurate and stable;

7. The controller operation interface is available in both Chinese and English, and the real-time operation curve can be displayed on the screen;

8. have10 sets of programs, 100 segments per set, with a capacity to cycle 999 steps per segment, and a maximum time setting of 99 hours and 59 minutes per segment;

9. After inputting the data and experimental conditions, the controller has a screen lock function to avoid manual touch and shutdown;

10. haveRS-232 or RS-485 communication interface, which can be programmed on a computer to monitor the testing process and perform functions such as automatic power on/off, curve printing, and data processing;

11. The controller has an automatic screen saver function, which better protects the LCD screen (prolonging its lifespan) during long-term operation;

12. Accurate and stable control, long-term operation without drift;

13. 1s ~999hThemTheSThe spray stop time can be set arbitrarily;

14. The program or fixed value test can be set arbitrarily, and can be based onRequest the program to conduct a cyclic test;

15. instrument displayexperimentTemperature, andthree-channelgas flow rate(Each channel contains nitrogen flow and hydrogen sulfide flow);

16. All functions can be set and operated on this screen;

17. In operation or setting, if an error occurs, a warning signal will be provided;

19. The main control components are all Schneider electrical components from France, ensuring the reliable performance of the equipment.

3.19 Protection System

1Gas leakage alarm handling;

2Hazardous gas treatment and protection system;

3Exhaust fan overcurrent protection;

4. transportation

The test box is of integral type and can be transported as a whole

5. Terms of Use

The user guarantees the following conditions

environment/Venuecondition

ltemperature5℃~30 ℃ relative humidity: ≤85% atmospheric pressure86kPa~106kP

lThe ground is flat, well ventilated, and free of flammable, explosive, corrosive gases and dust

lThere is no strong electromagnetic radiation source nearby

lThere is a drainage floor drain near the equipment (distance from the refrigeration unit)Within 2 meters

lGround bearing capacity of the venue: not less than200kg/m2

lLeave appropriate maintenance space around the equipment

lThe airflow around the equipment is unobstructed, without high concentration dust, corrosive or flammable gases

lSuggest reserving independent storage space

Power supply conditions

lVoltage:AC220V/50HZ

lAllowable voltage fluctuation range:AC(1±10%)

lAllowable fluctuation range of frequency:(1±1%)50Hz

lThe grounding resistance of the protective grounding wire is less than4Ω; TN-S power supply or TT power supply

lRequire users to configure corresponding capacity air or power switches for the equipment at the installation site,

lAnd this switch must be independent and specifically designed for use with this device

lTotal maximum power:1000W

6. Precautions

1. Due to the strong adsorption of hydrogen sulfide, it is necessary to wear a specialized gas mask and rubber gloves when operating this equipment;

2. Before entering the laboratory each time, it is necessary to observe whether the three color lights that come with the equipment are in green state

3. Nitrogen pressure holding test must be conducted during each test before conducting deoxygenation and hydrogen sulfide tests

HIC anti hydrogen induced cracking hydrogen sulfide corrosion test deviceThe equipment mainly consists of the following parts:

1 Reaction kettleThree sets (standard configuration)

2 trafficThree sets of experimental equipment (standard configuration)

3 Leakage alarm deviceTwo sets (standard configuration)

4 One anti-corrosion all steel fume hood (standard configuration)

5 Two traps (standard configuration)

6 Two beakers (standard configuration)

7 Exhaust gas filtration device (standard configuration)

8 8L hydrogen sulfide gas bottle (standard configuration, equipped with dedicated pressure reducing valve)

9 8L nitrogen gas bottle (standard configuration, equipped with a dedicated pressure reducing valve)

10 Filter consumables (*500g two bottles, 2kg large particle activated carbon)

11 sprayFilter tower(optional)

12 Electronic scale(optional)

13 Gas(Optional, except for equipment configuration)

14 backupPressure reducing valve (optional)

15 Alarm (optional, in addition to standard)