HDGC3960 DC System Comprehensive Tester
Product features
1、 Comprehensive testing function
Comprehensive testing shows the measurement of DC current, DC voltage, AC voltage, and ripple voltage, and calculates the voltage stabilization accuracy, current stabilization accuracy, voltage stabilization ripple factor, and current stabilization ripple factor.
2、 Voltage stabilization accuracy measurement function
When the AC input voltage varies within the range of ± 10% of the rated voltage and the load current varies from 0 to 100% of the rated value, the voltage stabilization accuracy of the DC output voltage is at any value within the adjustment range.
3、 Stable current accuracy measurement function
4、 Ripple accuracy measurement function
Calculate the voltage ripple coefficient and current ripple coefficient by taking half of the difference between the peak and valley values of the DC voltage output from the charging device and the average value of the DC output voltage.
5、 Battery discharge function
6、 Automatic protection function
Automatic protection can be achieved by setting the battery pack to three threshold alarms: low protection voltage, discharge capacity, and discharge time.
7、 Data analysis function
System analysis of testing can be conducted through PC software.
Product Features
2. Fully automatic testing: By setting relevant testing parameters based on the technical specifications of the charger, the device can automatically complete functions such as AC voltage adjustment, load resistance, parameter testing, automatic recording of test values, and stopping testing.
3. It can automatically detect and record the voltage of the entire battery pack in real-time online.
Product Parameters
project |
Host rules |
load current |
Applicable voltage level |
size |
weight |
host |
48V 150A |
0-150A |
48V |
415*180*310 |
9Kg |
48V 300A |
0-300A |
48V |
570*225*460 |
15Kg |
|
220V 30A / 110V 30A |
0-30A |
220V / 110V |
260*350*600 |
13Kg |
|
220V 50A / 110V 50A |
0-50A |
220V / 110V |
500*360*420 |
15Kg |
|
220V 50A / 110V 80A |
110V:0-50A 220V:0-80A |
220V / 110V |
500*360*420 |
15Kg |
|
220V 50A / 110V 100A |
0-100A |
220V / 110V |
600*235*460 |
18Kg |
|
voltage regulator |
rated voltage |
15KVA |
|||
input voltage |
380+10% |
||||
output voltage |
300-450V |
||||
rated current |
20A |
||||
volume |
260*350*600(mm) |
||||
weight |
18kg |
||||
precision |
Voltage ± 0.5%, current ± 0.5% |
||||
Ripple coefficient |
0.01%-10%±0.02% |
||||
power supply |
AC220V±10% |
||||
working environment |
-20℃+55℃ |
||||
display screen |
320 * 240 color pattern LCD+touch screen |
||||
Memory capacity |
128MB FLASH |
||||
communication interface |
USB |
||||