Application industry:
MS5056/MS5056 Lite:industryROpre-film
MS5056 Pro:Industrial cooling circulating water, complex water quality environment
Instrument features:
● Adopting three parameter composite residual chlorine/Chlorine dioxide electrode, realizing a probe to output residual chlorine (chlorine dioxide)pHAnd the three parameter values of temperature. Temperature inside the electrode andpHDual parameter compensation function, using a unique algorithm to reduce the impact of temperature and flow rate on residual chlorinepHThe impact of value. The electrode implementation system has no membrane or filling solution, resulting in low maintenance.
●MS5056 ProThe series residual chlorine analyzer comes with a self-cleaning flow cell as standard, which can achieve active cleaning of the probe and is suitable for more harsh and complex water samples. It can effectively reduce the daily maintenance of the probe and make it simpler and more convenient to use.
The chlorine electrode is made of gold material, which is more stable.
The turbidity sensor adopts a method that complies withUSEPA 180.1Standard Color TemperatureLEDDetecting the light source, yesUSEPA 40 CFR 141.74(a)(1)The approval method. The highest resolution can reach0.001NTULong term stable operation.
●MS5056 ProThe series adopts turbidity probes that are more suitable for industrial sites, embedded optical glass detection channels that are resistant to pollution, and more suitable for applications such as cooling and circulating water.
For different application scenarios, customers can choose residual chlorine or chlorine dioxide measurement according to their needs. And optional conductivity andORPProbe.
● High chlorine water quality environment/In seawater environment, customers can choose corrosion-resistant materials(CPVCMaterials such as residual chlorine or chlorine dioxide electrodes, as well as titanium alloy turbidity probes.
The installation of the instrument takes up a small area and is easy to install; Pre calibration at the factory, simple on-site operation and maintenance, and low professional requirements for operators.
Measurement principle:
● Residual chlorine/Chlorine dioxide probe: using the principle of constant voltage measurement, with a three electrode structure (working electrode, counter electrode, and reference electrode), and integratedpHGlass electrode andPT100Temperature electrode, solving residual chlorine measurement under complex working conditionspHTemperature compensation;
Turbidity probe: The light source uses warm white lightLED(Color temperature)3200K)Based on90The principle of scattering is used to measure turbidity in water, which meets the requirementsEPA-180.1standard
●ORPProbe: a composite electrode structure based on platinum electrode and reference electrode, used for accurate measurement of oxidation-reduction ability in water;
Conductivity: Measurement principle of graphite four electrodes, and built-inPT100Temperature compensation, capable of achieving a wide range(0-100mS/cm)Accurate measurement of conductivity.
| Standard chlorine probe parameters: | |||
|---|---|---|---|
| measurement parameters | Residual chlorine/chlorine dioxide | PH | temperature |
| measurement range | 0-5 mg/L Cl2Or CLO2plan | 2-12 | -5℃ ~65℃ |
| Detection limit | 0.01 mg/L | 0.01 pH | -5℃ |
| display resolution | 0.01 mg/L | 0.01 pH | 0.01℃ |
| accuracy | ± 0.01 ppm or ± 2% reading, whichever is greater | ± 0.02pH@25 ℃ | 1% |
| repetitiveness | 2% | 0.01 pH | 0.5℃ |
| minimum resolution | 0.01 mg/L | 0.01 pH | 0.1℃ |
| response time | T90 ≤ 120S | T90 ≤ 30S | T90≤ 20S |
| measurement interval | continuous measurement | continuous measurement | continuous measurement |
| Joint protection level | IP65 | IP65 | IP65 |
| signal output | 4-20mA and RS-485 dual output | RS-485 output | |
| Probe material | SS304 shell, electrode front end made of gold+platinum+glass+CPVC+SS304 | ||
| Standard turbidity probe parameters: | ||
|---|---|---|
| measurement parameters | Turbidity (applicable to MS5056/MS5056 Lite series) | Turbidity (applicable to MS5056 Pro series) |
| measurement range | 0-10/10-40NTU | 0-100NTU |
| Detection limit | 0.001 NTU | 0.5 NTU |
| display resolution | 0.001 NTU | 0.1 NTU |
| accuracy | ± 0.01NTU or ± 2% reading, whichever is greater | ± 0.5NTU or ± 2% FS, whichever is greater |
| repetitiveness | 1% | 2% |
| minimum resolution | 0.001NTU | 0.1NTU |
| response time | T90 ≤ 30S | T90 ≤ 30S |
| measurement interval | continuous measurement | continuous measurement |
| Joint protection level | IP65 | IP65 |
| signal output | 4-20mA and RS-485 dual output | 4-20mA and RS-485 dual output |
| Probe material | SS304 shell+optical glass | CPVC shell+optical glass |
| Optional probe parameters: | ||
|---|---|---|
| measurement parameters | ORP | conductivity |
| measurement range | ±1500mV | 0-100,000μS/cm |
| Detection limit | -1500 mV | 10 μS/cm |
| display resolution | 1 mV | 1 μS/cm |
| accuracy | ± 20mV or 2% FS, whichever is greater | ± 10 μ S/cm or ± 1% reading, whichever is greater |
| repetitiveness | 2% | 1% |
| minimum resolution | 1 mV | 1 μS/cm |
| response time | T90 ≤ 25S | T90 ≤ 20S |
| measurement interval | continuous measurement | continuous measurement |
| Joint protection level | IP65 | IP65 |
| signal output | 4-20mA and RS-485 dual output | 4-20mA and RS-485 dual output |
| Probe material | Shell: CPVC; Electrode: Platinum | Shell: CPVC; Electrode: Graphite |
| System parameters: | |
|---|---|
| measurement parameters | |
| display screen | 4.3 "TFT 480x272 touch screen |
| power supply | 100-240VAC, 50/60 Hz |
| power | About 30W |
| Analog output | Residual chlorine pH、 Turbidity and temperature each have a 4-20mA output |
| communication interface | RS485、Modbus RTU、 Relay (optional: 2-channel DC relay, rated voltage 24 VDC, total rated current up to 1.5A; 3-channel AC relay, rated voltage 220 VDC, total rated current up to 5A) |
| Data export | USB drive |
| System upgrade | USB drive |
| Operating Temperature | 5-45℃ |
| Storage temperature | -20~55 ℃ (excluding probe) |
| relative humidity | 5% -95% (non condensing) |
| altitude | ≤ 2000 meters |
| Water sample requirements | MS5056/MS5056 Lite Temperature: 5~45 ℃; Pressure: 0.05~0.25 MPa. If it exceeds 0.25 MPa, a pressure reducing valve needs to be added; Flow rate of circulation pool: greater than 470mL/min MS5056 Pro Temperature: 5~45 ℃; Pressure: 0.05~0.2 MPa; Flow rate of circulation pool: greater than 200mL/min |
| Box material | All plastic, corrosion-resistant |
| size | 750mm X 500mm X 230.5mm |
| weight | Approximately 25 kilograms (including packaging, maximum weight) |