Greisinger oxygen detector

NegotiableUpdate on 12/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Greisinger Oxygen Detector G1610 $r $n Oxygen Analyzer/Oxygen Measuring Instrument $r $n $r $n Emphasize $r $n $r $n Modern and Practical - Pocket Size $r $n Waterproof Rating IP65 and IP67 $r $n With Just One Button, Comfortable Air Balance $r $n $r $n With Illuminated 3-Row Display Screen/Elevated Display Screen $r $n Durable and Maintenance Free Sensor $r $n Scuba Diver Variant "T": Nitrogen Oxide MOD Calculation $r $n Durable and Long Battery Life $r $n Made in Germany $r $n
Product Details

Greisinger oxygen detector

Greisinger oxygen detector

Oxygen analyzer/oxygen measuring instrument

emphasize

Modern and practical - pocket size
Waterproof rating IP65 and IP67
Just press the button to achieve comfortable air balance
Just press the button, illuminated 3-row display screen/elevated display screen
Durable and maintenance free sensors
Scuba diver variant "T": MOD calculation of nitrogen oxides
Durable and sturdy, with a long battery life
Made in Germany

Application field

The G 1690 is an inexpensive and submersible gas measurement device, but it is also an inexpensive but high-quality entry-level device used for many other oxygen measurements, such as those with protective gases.

Technical Specifications
Measurement range: Oxygen concentration:
G 1690-35 / G 1690T-35:
The volume of oxygen is 0.0 100.0%, it is recommended to have an oxygen volume of 0.2 .. 35.0%
(Apart from reducing accuracy)
Diving gas standards for recreational diving,
Protective gases have higher carbon dioxide content, even more.
G 1690-MAX / G 1690T-MAX:
0.0 of O2 volume .. 100.0%
(also applicable to oxygen content<=0.2 or above -% O2), for example, used to protect gases with the following characteristics
Low oxygen content or high percentage oxygen mixture
Low carbon dioxide content
Resolution 0.1 vol% O2
G 1690T-XXX: Leisure Diver Version:
The MOD calculation of nitrogen oxides reaches up to 36%
0 +169 feet. MOD resolution of 1 foot.
0 +60 m MOD resolution 1 m
Accuracy of calibrated equipment at nominal temperature:
G 1690u-35: Sensor GOEL 370
<2 vol . -%O2:+/- 0.2%
<35% (volume) O2:+/-0.5%, not mentioned above
G 1690u-MAX variant: sensor GOEL 381
<2 vol . -%O2:+/- 0.1%
Less than 35% oxygen:+/-0.5%