characteristic
1. D/8 geometric optical structure, compliant with CIE Number15,GB/T 3978,GB 2893,GB/T 18833,ISO7724/1,ASTM E1164,DIN5033 Teil7;
2.Tai Shuang TS7700Grating spectrophotometerAdopting a combination LED light source with high lifespan, low power consumption, and full spectrum, including UV/exclusion of UV;
3. The diameter of Φ 8/4mm can be switched freely, and the platform/nozzle measurement diameter can be easily switched to adapt to more tested samples;
4. Dual path system, with an optical resolution of less than 10nm in the visible light range, capable of simultaneously measuring the SCI and SCE spectra of samples;
5. Measure sample spectra, Lab data is accurate, and can be used for color matching and accurate color transfer;
6. High hardware configuration: 3.5-inch TFT true color screen, capacitive touch screen, 1000 line glitter grating, silicon photovoltaic array detector with large photosensitive area, etc;
7. USB/Bluetooth dual communication mode, with wider adaptability;
8. Super dirt resistant and stable standard whiteboard;
9. Large capacity storage space, capable of storing over 30000 pieces of test data;
10.2/10 standard observer angle, multiple light source modes, multiple color schemes, chromaticity indicators that meet multiple standards, and meet the color measurement needs of various customers;
11. Camera framing and positioning, stable film platform measurement and positioning;
12. The PC software has * function extensions.
Tai Shuang TS7700Grating spectrophotometertechnical parameters
Product Model |
Tai Shuang TS7700 |
lighting method |
D/8 (diffuse illumination, receiving in 8 ° direction); |
characteristic |
Dual testing caliber, used for laboratory color accuracy analysis and transmission; |
Integral sphere size |
Φ40mm |
照明光源 |
Combination full spectrum LED light source, UV light source |
Spectral method |
Planar grating spectroscopy |
sensor |
Silicon photodiode array (double row 40 groups) |
Measuring wavelength range |
400~700nm |
Wavelength interval |
10nm |
Half bandwidth |
10nm |
Reflectance measurement range |
0~200% |
Measuring caliber |
Dual caliber: MAV: Φ 8mm/Φ 10mm; SAV:Φ4mm/Φ5mm |
Light containing method |
Simultaneously testing SCI/SCE |
color space |
CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99 Munsell(C/2) |
colour-difference formula |
ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) |
Other chromaticity indicators |
WI(ASTM E313,CIE/ISO,AATCC,Hunter),YI(ASTM D1925,ASTM 313), Same color spectral index Mt, color fastness, color fastness, strength, coverage |
Observer's perspective |
2°/10° |
Observing light source |
D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30) |
display |
Spectral chart/data, sample chromaticity values, color difference values/graph, qualified/unqualified results, color simulation, color bias |
measure time |
About 1.5 seconds (testing SCI/SCE simultaneously takes about 3.2 seconds) |
repetitiveness |
Spectral reflectance: MAV/SCI, standard deviation within 0.08% |
Inter station difference |
MAV/SCI, Δ E * ab within 0.15 (average value measured on 12 color plates of BCRA series II) |
measurement method |
Single measurement, average measurement (2-99 times) |
positioning method |
Display screen camera framing positioning, stabilizing film positioning |
size |
Length X width X height=129X76X217mm |
weight |
About 600g |
battery level |
Lithium battery, 3.7V, 5000mAh, 6000 cycles within 8 hours |
Lighting source lifespan |
More than 3 million measurements in 5 years |
display screen |
TFT True Color 3.5inch, Capacitive Touch Screen |
interface |
USB, Bluetooth ® four point two |
store data |
1000 standard samples and 30000 test samples (one data can include SCI/SCE at the same time) |
language |
Simplified Chinese English, Traditional Chinese |
Operating temperature range |
0~40 ℃, 0~85% RH (no condensation), altitude: below 2000m |
Storage temperature range |
-20~50 ℃, 0~85% RH (no condensation) |
Standard Appendix |
Power adapter, data cable, instruction manual, quality management software (downloadable from * website), black and white calibration box, protective cover, wristband, Ø 8mm platform caliber, Ø 8mm pointed caliber, Ø 4mm platform caliber, Ø 4mm pointed caliber |
Optional Accessories |
Micro printer, powder testing box |