characteristic
20Any combination of support sensors
System upgrade and expansion are very easy, plug and play
Centralized power supply, input voltage100-240VACperhaps24VDC
Output relays and analog currents have no limit on the number of groups
Digital signal output, such asMODBUS, PROFIBUS
Can be connectedMODEM(Analog orGSMType)
USBInterface, convenient for fast and easy transmission of data
Unique electronic key to prevent illegal operations
IQ-LabLinkCalibration system makes calibration easier
Built in lightning protection design
Are you considering building an online testing network that reserves future expansion and upgrade capabilities and can integrate all testing points together?2020 XTIt will be your wise choice.
2020XTAdopting modular design, different functions are completed by various unique functional modules. This design reserves powerful expansion capabilities. When it is necessary to enhance test points or increase test parameters, simply adding new sensors or functional modules is sufficient, without the need to purchase the entire system (host and sensors). Moreover, the newly added components can seamlessly integrate with the existing system, saving a significant amount of cost for reinstallation and debugging. Whether it is a small, medium or even large sewage treatment plant, only one set needs to be purchased2020XTThe system can cover all online analytical instruments from the inlet, biochemical degradation tank, final sedimentation tank to the discharge outlet, with testing parameters includingpH/ORPTemperature, dissolved oxygen, conductivity, turbidity, suspended solids concentrationCOD/BOD/TOCAmmonia nitrogen, nitrate nitrogen, etc.
Any combination of sensors
allIQThe sensors are equipped with standard communication interfaces that can communicate with any deviceIQModule communication. Therefore, it is easy to integrate different types of sensors into one system, and users can flexibly choose the required testing parameters, which means that a set of sensors can be usedIQ Sensor NetThe system simultaneously monitors the water quality indicators of the inlet and outlet of a sewage treatment plant, as well as multiple aeration tanks, or various water quality indicators of the monitoring section of the water quality automatic station.
Built in lightning protection circuit,EMCHigh level of protection
This isWTWThe advantage lies in,WTWAll online instruments have lightning protection function, and users do not need to install lightning protection facilities specifically. The electromagnetic protection level is very high, ensuring user operation safety and reliable system operation.
I Q - L a b L i n k – Communication with the laboratory world,Make calibration easier
Safe, fast, and reliable data transmission
Automatically verify the accuracy of calibration data
2020XTThere is an internal data storage function, which can be accessed throughIQ-LabLinkThe function can store data in2020XTExchange between laboratory instruments is achieved through a common methodUPlate. beltUSBThe laboratory instruments for the interface includespectroLab 6100(Visible light spectrophotometer)andspectroLab 6600 (Ultraviolet visible spectrophotometer)On site calibration is to calibrate the sensorThe nearby water samples are taken to the laboratory for analysis, and the laboratory results are input into the instrument to complete the calibration. This takes into account the composition of the sample and the background ion intensity, which can ensure excellent testing accuracy and stability. Combining with usWTWA multifunctional water quality analyzer that only requires oneUThe disk can automatically input laboratory data intoIQIn the system, it is very convenient.
approveElectronic key for programming
Protect unauthorized use
Personalized Access
When in2020XTWhen the electronic key function in the controller is activated,UThe disk is like a key to enter the system. A coding file
storageexistUOn the disk, access to the system is only allowed after reading the file. It is also possible to restrict only a portion of the functions to achieve personalized access.
2020XTTechnical Parameter
|
system |
|
|
authentication |
ETL, cETL, CE |
|
electromagnetic compatibility |
EN 61326, Class B; FCC Class A |
|
EMCprotection |
built-inWTWUnique lightning protection circuit |
|
wire connection |
allIQAll modules pass through2Core shielded wire simultaneously transmits power and test signals, enhanced typeEMCProtective effect, various connection methods such as star shaped, tree shaped, streamlined, or multi star shaped. |
|
transmission distance |
Total cable length: large1,000rice(No signal amplification),addSignal amplifier moduleMIQ/JBRCan you pleaseextend1,000rice |
|
Wireless transmission |
Wireless transmission level1, can be transmitted100Mi,big300Rice(connect3A wireless transmission module) |
|
controller/display terminal |
|
|
MIQOverlay after module |
Composite mechanical and electronic connections for quick installationMIQmodule |
|
USBinterface |
USB-A(Active type) |
|
display |
chartLCDBacklit black and white display screen,320X240dot matrix,Visible range114X86 mm |
|
Function keys |
5Function keys: respectively for testingMCorrectionCSet upSConfirmOKAnd returnESCkey 4individualQuick input key |
|
data storage |
MIQ/TC 2020XT:Storable525,600set of data |
|
electricitysourcesupply |
From the hangingIQObtain on module |
|
Surrounding environment |
operation temperature: -20 °C … +55 °C, Storage temperature: -25 °C … +65 °C |
|
Shell material |
ASA(Acrylonitrile Styrene Acryloesterpolymer)engineering plastic |
|
protection grade |
IP 66 |
|
size |
210×170×40 mm |
|
weight |
make an appointment700g |
|
Warranty period |
three years |
|
MIQmodule |
|
|
Overlay installation |
Allow more3individualMIQModule stacking installation forms a stack, which can be hung at the frontMIQ/TC 2020 XTdisplay terminal |
|
Cable entrance and exit |
4A thread sealant sleeve(M16X1.5) |
|
connecting terminal |
Opening the casing reveals the wiring terminals and the core of the hard cable: 0.2…4.0 mm2,Flexible cable core:0.2…2.5 mm2 |
|
IQDedicated interface |
Used to connectIQDigital sensors and remote connectionsIQmodule |
|
Other functions |
On the side of the module, there are2individualLEDLamp (red)/Yellow), can indicate the working status of the module, polarity self-protection, on-site recognition function, endpoint indication function |
|
Surrounding environment |
operation temperature: -20 °C … +55 °C, Storage temperature: -25 °C … +65 °C |
|
electricitysourcesupply |
From the hangingIQObtain on module |
|
Shell material |
contain20%Glass fiber polycarbonate |
|
protection grade |
IP 66 |
|
size |
144×144×54 mm |
|
weight |
make an appointment500g |
|
Ordering Information |
||
|
model |
describe |
order No |
|
TC 2020 XT |
central control unit,pass throughMODBUSoperate,Can be installed at any point in the system |
470 000 |
|
MIQ/TC 2020 XT-H3 |
Multi parameter measuring instrument includesMIQ/TC 2020 XT + MIQ/CR3 + MIQ/PSmodule, 100-240VACpower supply, threeroad0/4-20mAAnalog output and3Road relay output,Connectable20branchIQsensor |
470 016 |
|
MIQ/TC 2020 XT-H3 C6 |
Multi parameter measuring instrument includesMIQ/TC 2020 XT + MIQ/C6+ MIQ/PSmodule, 100-240VACpower supply, sixroad0/4-20mAAnalog Output,Connectable20branchIQsensor |
470 017 |
|
MIQ/MC2 |
IQController module,Equipped with automatic pressure compensation andUSB+LANinterface |
471 015 |
|
MIQ/MC2-MOD |
IQController module,Equipped with automatic pressure compensation andMODBUS RTU/RS485Connection andUSB+LANinterface |
471 016 |
|
MIQ/MC2-PR |
IQController module,Equipped with automatic pressure compensation andPROFIBUS-DPConnection andUSB+LANinterface |
471 017 |
|
MIQ/PS |
100-240VACPower module,Multiple systems available for installation6individual |
480 004 |
|
MIQ/24V |
24 VAC/24 VDCPower module |
480 006 |
|
MIQ/CR3 |
3road0/4-20mAAnalog output and3Road relay output |
480 014 |
|
MIQ/C6 |
6road0/4-20mAAnalog Output |
480 015 |
|
MIQ/R6 |
6Road relay output |
480 013 |
|
MIQ/2-MOD |
IQoutput module,Equipped with automatic pressure compensation andMODBUS RTU/RS485connect |
471 018 |
|
MIQ/2-PR |
IQoutput module,Equipped with automatic pressure compensation andPROFIBUSconnect |
471 019 |
|
MIQ/CHV PLUS |
Electromagnetic valve module,Automatic control of compressed air cleaning |
480 018 |
|
MIQ/JB |
connecting module,have4individualIQconnection terminal |
480 008 |
|
MIQ/JBR |
connecting module,Equipped with relay amplifier,Used for exceeding1kmThe long cable |
480 010 |
|
MIQ/IC2 |
Input,connect2road0/4-20mAanalog signal |
480 016 |
|
MIQ/Blue PS |
wireless communication module,used forIQ SensorInternal system wireless connection |
480 021 |