Welcome Customer !

Membership

Help

Duzhi Instrument (Shanghai) Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Duzhi Instrument (Shanghai) Co., Ltd

  • E-mail

  • Phone

    15921165535

  • Address

    No. 418 Huajing Road, Shanzhong Science and Technology Park, Waigaoqiao Free Trade Zone, Pudong New Area, Shanghai

Contact Now

German Fischer thickness gauge Dualscope MP40E-S

NegotiableUpdate on 01/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
This instrument has been widely used in fields such as automotive, aviation, electroplating, and mechanical processing If the ED10 dual-purpose probe is configured, it can simultaneously measure the thickness of paint, plastic, epoxy resin, etc. on substrates such as Zn/Fe, Cu/Fe, and aluminum oxide oxidation, as well as Fe, Cu, Al, Zn Alloy, Cu Alloy, etc. without replacing the probe, which is convenient and fast.
Product Details

Product description


This instrument has been widely used in fields such as automotive, aviation, electroplating, and mechanical processing If the ED10 dual-purpose probe is configured, it can simultaneously measure the thickness of paint, plastic, epoxy resin, etc. on substrates such as Zn/Fe, Cu/Fe, and aluminum oxide oxidation, as well as Fe, Cu, Al, Zn Alloy, Cu Alloy, etc. without replacing the probe, which is convenient and fast. This instrument can also be equipped with magnetic induction and eddy current single probes to meet different measurement needs. This model has long been discontinued, welcome to learn about the new model.


Ideal for measuring:

Non ferrous metal coatings (such as chromium, copper, zinc, etc.) on iron or steel.
Paint, wax, and synthetic coatings on iron or steel.
Non conductive coatings are applied on non-ferrous metal substrates, such as paint, Lacquer, and synthetic coatings on aluminum, copper, brass, zinc, and stainless steel.
Aluminum anodized layer.
Measure the thickness of each layer in the coating system (double coating) of galvanized and repainted steel in one step.


Instrument Introduction:

The dual-purpose probe ED10 with instrument configuration has two measurement functions: magnetic induction and eddy current
The instrument can automatically switch to the corresponding working mode according to the different substrates
The instrument can also use different magnetic induction and eddy current probes to cope with special measurements
It has calibration and zero position functions for both magnetic induction and eddy current
Continuous measurement function, capable of obtaining stable results
Large window LCD with two row dot matrix dialogue display for clearer operation
. Setting of metric and imperial units
The upper and lower limits are set, and once the limit is exceeded, there will be different beeping sounds to prompt
. It has data statistics function: average value, maximum value, minimum value, standard deviation, measurement frequency
It has data statistics function, can set 1000 data groups, and store 10000 data.
Keyboard lock function to prevent incorrect calibration
RS232 interface
By purchasing additional transmission software and dedicated cables, the data from the instrument can be transmitted to the Excel interface of the computer for easy editing and printing.
DC12V external power socket, can also be connected to an external power transformer and 12V DC power supply


Please select the probe according to your measurement requirements. There are probe selection items under the magnetic induction and eddy current thickness gauge columns. Combined with the probe ED10, it can have two measurement functions: magnetic induction and eddy current.

Measurement parameters when probe ED10 is set to dual-purpose:
Magnetic induction: Measurement range: 0-800 μ m (0-32 mil)
Eddy current: Measurement range: 0-800 μ m (0-32 mil)

Measurement parameters for probe ED10 set to single use:

Magnetic induction: Measurement range: 0-1500 μ m (0-60 mil)
Measurement accuracy: 0-50 μ Μ: 0.2 μ Μ
50~1500μM: 1%
Eddy current: Measurement range: 0-1200 μ m (0-48 mil)
Measurement accuracy: 0-100 μ Μ: 0.5 μ Μ
100~1200μM: 0.5%

Specific parameters:

DUALSCOPE®
MP0R USB
DUALSCOPE®MP0RH USB DUALSCOPE®
MP20E-S
DUALSCOPE®
MP40
DUALSCOPE®
MP40E-S
Paint, anodized layer, enamel or plastic coating on non-ferrous metals
Anodized layer on aluminum
Instruments, porcelain or plastic coatings on steel or iron
Non ferrous metal coatings on steel or iron

Data storage
Statistical Computing
Printing port/RS232 interface
Wireless transmission
Interchangeable plug-in smart probe
Integrated constant voltage probe
Measurement range (μ m) [mils] (0 ... 2000)
[0 ... 80]
(0 ... 2000)
[0 ... 80]
Depends on the probe Depends on the probe Depends on the probe
power supply battery battery battery AC power or battery AC power or battery
Weight [g] 60 60 230 230 230
Specification (height x width x depth mm) [height x width x depth] (85 x 64 x 30)
[3.4 x 2.5 x 1.2]
(85 x 64 x 30)
[3.4 x 2.5 x 1.2]
160 x 80 x 30
[4.25 x 2.6 x 1.2]
160 x 80 x 30
[4.25 x 2.6 x 1.2]
160 x 80 x 30
[4.25 x 2.6 x 1.2]