GC-8890 gas chromatographFeatures:
1. The instrument supports electronic flow/pressure display and carrier gas EPC control.
2. The GC-8890 chromatograph has a built-in "reverse control workstation" that enables computer data processing and reverse control functions, making it easy to operate, use, and manage. It can support the integration of multiple chromatography instruments simultaneously, simplifying document management.
3. Adopting a new generation of high-sensitivity "logarithmic amplifier".
GC-8890 is equipped with a 7-inch color LCD touch screen, which has a running timer and locking function. The display screen can directly display the output voltage signal value digitally, making it convenient to intuitively understand the signal status. The signal can be automatically zeroed.
5. Adopt 100M/Gigabit Ethernet communication interface, built-in IP protocol, and realize long-distance data transmission through LAN and Internet to facilitate the management of analysis data.
6. Multiple detectors (FID hydrogen flame detector, TCD thermal conductivity detector, ECD electron capture detector, FPD flame photometric detector, NPD, ZD, etc.) can be installed to meet the analysis and detection needs of different industries and samples.
7. GC-8890 is equipped with monitoring and recognition detectors, as well as automatic ignition function
8. The injection method can be selected as manual or automatic (equipped with an automatic sampler), making gas and liquid sample injection flexible and convenient. It can also be equipped with a programmable valve controlled split/non split injection system.
GC-8890 gas chromatographTechnical Specifications:
1. Operation display: 7-inch color LCD touch screen
2. Temperature controlled area: 8 channels; Temperature control range: Room temperature 4 ℃~450 ℃,
Increment: 0.5 ℃; Accuracy: ± 0.1 ℃
Program heating rate: 0-60 ℃/min
Stable time for column box from 300 ℃ to 50 ℃: ≤ 15 minutes
3. External events: 8 channels; Auxiliary control output 2 channels
4. Sample injector types: packed column injection, split/non split capillary injection, six way valve gas injection
Automatic sampler (optional)
5. Number of detectors: 3 (multiple); FID, TCD, ECD, FPD, and NPD are optional
6. Start injection: manual or automatic options are available
7. Communication interface: Ethernet: IEEE802.3
8. EPC electronic pressure and flow control system for carrier gas, with display function for pressure/flow of other gases.