Fatty acid residue chromatograph

NegotiableUpdate on 01/10
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The fatty acid residue chromatograph is manufactured using a large number of imported components, and has the characteristics of good stability and reliability, stable gas flow path, simple structural design, beautiful appearance, complete supporting facilities, strong professionalism, and long service life.
Product Details

The SP-7860 fatty acid analysis and solvent residue detection analysis chromatograph is a new high-performance gas chromatograph manufactured by Shanghai Nuoxi Instrument Co., Ltd. through long-term research and experimentation, using a large number of imported components.

1Fatty acid residue chromatographfeature
1. Using a large number of imported components for production and manufacturing, it has the characteristics of good stability and reliability, stable gas flow path, simple structural design, beautiful appearance design, complete supporting facilities, strong professionalism, and long service life.
2. 7-inch dot matrix Chinese LCD (can be equipped with touch screen), user-friendly design interface, one click operation

3. The split flow non split capillary injection system (including diaphragm blowing) ensures the stability and accuracy of the sample.

4. Data power-off protection function, the operating data set by the instrument can be saved for a long time after power failure.

5. Equipped with over temperature protection device. If the temperature exceeds the set point, the instrument will stop heating and report the fault on the display.

6. The instrument design is reasonable and flexible, capable of installing three types of detectors simultaneously, and has independent circuit systems and signal output terminals.

7. Flexible packed column and capillary column system, capable of connecting capillary columns of different diameters.

IIFatty acid residue chromatographtemperature control index

1. Column box: Accuracy ± 0.05 ℃ (measured at 200 ℃) at room temperature between 8 ℃ and 420 ℃.

2. Sample injector: Accuracy ± 0.05 ℃ at room temperature between 8 ℃ and 420 ℃ (measured at 200 ℃).

3. Detector: Accuracy ± 0.05 ℃ at room temperature between 8 ℃ and 420 ℃ (measured at 200 ℃).

4. Six way temperature control: suitable for installing multiple temperature control requirements such as conversion furnaces.

5. Column temperature box parameters:

6. Temperature control accuracy: accuracy ± 0.1 ℃ at room temperature between 8 ℃ and 420 ℃.

7. Column temperature box volume: 280mm × 300mm × 250mm.

8. Program heating order: eight orders. (21 levels can be added)

9. Program heating rate: 1 ℃ -50 ℃.

10. Constant temperature holding time for each stage: 0-300min (1min increments).

11. Automatic rear door design ensures rapid cooling.

12. A high-power, low-noise rotating fan ensures temperature uniformity.

3、 Pneumatic system

The carrier gas flow rate adopts a dual stability design of first stabilizing and then stabilizing the flow.

Jingque's calibrated pneumatic control valve components have high reproducibility and stability.

4、 Injection method

Fill the column head for injection.

Filling column gasification injection.

Capillary diversion/non diversion injection: back pressure valve control technology, linear diversion.

Six way valve gas injection.

Online injection: 24-hour continuous injection without supervision.

5、 High sensitivity detector parameters ensure the accuracy of data

detector
parameter
Hydrogen flame detector
(FID)
thermal conductivity detector
(TCD)
Electron capture detector
(ECD)
Flame photometric detector
(FPD)
Nitrogen and phosphorus detector
(NPD)
High operating temperature 420℃ 400℃ 350℃ 400℃ 400℃
detection limit ≤1×10-12g/s ≥10000mvml/mg ≤1×10-13g/ml(r-666) Mp≤5×10-12g/s
Ms≤5×10-11g/s
Mn≤5×10-13g/s
Mp≤1×10-12g/s
baseline drift ≤0.10mv ≤0.15mv ≤0.10mv ≤0.15mv ≤0.15mv
Baseline noise ≤0.01mv ≤0.015mv ≤0.02mv ≤0.02mv ≤0.02mv
linear range ≥106 ≥104 ≥104 ≥103 ≥103
Technical Features Fully automatic ignition Imported rhenium tungsten wire
Cross current circuit
Ni63 radioactive source with cleaning gas path Top photomultiplier tube microanalysis
Other parameters: Dimensions: 620 * 480 * 520mm Weight: 70kg Input power supply: AC 200V ± 10% 50HZ 1800W