Overview
The fully automatic liquid-liquid extraction instrument adopts a new closed silent clean air internal circulation oscillation principle and bidirectional gas-liquid mixing technology for the pre-treatment of liquid-liquid extraction in laboratory water quality testing projects such as oil, volatile phenols, anions, etc. The equipment displays and sets multiple extraction parameters through a large LCD touch screen to meet the extraction requirements of different samples. The experimental process does not require manual supervision, and the equipment realizes functions such as automatic extraction, automatic deflation, automatic collection, automatic drainage, and automatic cleaning.
Product Details

Fully automatic liquid-liquid extractor with airflow automatic cleaning and air release



Scope of Application


Meet the national standard: "GB 7494-87 Determination of anionic surfactants in water quality - Methylene blue spectrophotometric method"

Meet the national standard: "HJ 970-2018 Determination of Water Quality and Petroleum by UV spectrophotometry"

Meet the national standard: "HJ 503-2009 Determination of volatile phenols in water quality -4-aminoantipyrine spectrophotometric method"

Meet the national standard: GB/T 16488-1996 Water quality - Determination of petroleum and animal and vegetable oils - Infrared photometric method

Meet the national standard: "HJ 637-2018 Water Quality - Determination of Petroleum and Animal and Vegetable Oils - Infrared Spectrometric Method"

Meet the national standard: "GB/T 16488-1996 Water quality - Determination of petroleum and animal and vegetable oils - Infrared photometric method"


Main features


1. 7-inch large LCD touch screen with one click system operation, simple and convenient

2. Supports the use of multiple specifications of extraction bottles (250/500/1000ml), and the gas valves are all made of PTFE material

3. A 6-digit operating system that can independently complete the extraction of 6 sets of samples

4. Extraction time, interval time, and extraction cycle can be independently set and adjusted as desired

5. Adopting high-precision metering pump for automatic and precise injection, without the need for manual feeding, fast and convenient

6. The extraction rate can be independently adjusted as desired

7. Automatic extraction, automatic venting, automatic collection, automatic drainage, automatic cleaning and other functions

8. Equipped with a retractable waste liquid tank and a filtration system, there is no need for manual drainage

9. The device has built-in air purification function to ensure the cleanliness of the extraction gas path

10. Equipped with waste liquid activated carbon filtration and purification function, reducing environmental pollution

11. Can operate the machine remotely on the mobile phone, and has SMS reminder function (optional)


全自动液液萃取仪 气流式 自动清洗放气




Fully automatic liquid-liquid extractor with airflow automatic cleaning and air release


working process


The multi link automatic liquid-liquid extractor adopts gas-liquid bidirectional mixing technology, which is used for liquid-liquid extraction pretreatment of oil, volatile phenols, anions and other items in laboratory water quality testing. Widely applicable to laboratories that require extraction and treatment in environmental protection, hygiene and epidemic prevention, water supply and drainage, universities, research institutes, related enterprises, and other fields.

The traditional process of radioactive water sample treatment includes a series of steps such as automatic liquid-liquid extraction instrument sampling, concentration, transfer, washing, burning, ashing, weighing, etc. When concentrating and heating, the sample size should not exceed half of the beaker, and the temperature should not exceed 80 ℃. The operation must be careful and meticulous. The entire water sample pretreatment process is quite long and cumbersome, which brings a lot of inconvenience to the experimenters. The multi link automatic liquid-liquid extraction instrument integrates the far-infrared radiation heating system, intelligent sampling system, and high-precision concentrated automatic liquid-liquid extraction instrument scaling system according to the national standard method. It has functions such as adjustable heat source power, constant temperature heating, modular heat source kit conversion, slow sampling in batches, quantitative control of evaporation and concentration, intelligent voice alarm, etc., realizing various sample evaporation and concentration without personnel duty, intelligent automation, safety and reliability. Suitable for pre-treatment of total alpha beta gamma radioactive indicators in environmental samples such as drinking water, surface water, sewage, and atmospheric deposition in various industries.
Combining traditional methods of automatic liquid-liquid extraction, the shortcomings are eliminated, and a vertical oscillation extraction method is adopted. The extraction process automatically releases gas, and the gas source is collected and processed uniformly through a protective core. One click start, automatic injection, silent oscillation extraction, unified collection of exhaust gas filtered by the filter element and automatically discharged, realizing the intelligence and automation of the entire extraction experiment. The multi link automatic liquid-liquid extraction instrument has a high degree of automation, which not only improves the extraction efficiency, but also effectively avoids the contact between people and toxic and volatile gases, as well as the secondary pollution caused by direct discharge of exhaust gas.