Fully Automated Laboratory Water Quality Analysis System VT-7900
-Working principle:
Fully Automated Laboratory Water Quality Analysis System VT-7900isA COD fully automatic analyzer based on HJ/T 399-2007 "Determination of Chemical Oxygen Demand in Water Quality - Rapid Digestion Spectrometric Method" and USEPA digestion colorimetric method. This product integrates functions such as automatic sample/dosing, stirring, mixing, cleaning, digestion, and measurement, aiming to achieve high automation of the entire experimental process, improve the accuracy and precision of experimental data, reduce the harm of laboratory chemical reagents to experimental personnel, and ensure the safe, accurate, and effective conduct of water quality detection and analysis.
-Measurement parameters:
COD
-Typical applications:
Petrochemical, municipal, environmental protection, third-party testing and other industries
-Instrument features:
The entire process of sample pretreatment and measurement is automated, freeing up manpower and achieving unmanned operation.
● Possess the ability to pre process and measure large quantities of samples
Less reagent usage, safer and more environmentally friendly, using Hash 16mm COD pre made reagent
Using high-precision injection pumps to achieve precise sample addition and reduce manual experimental errors
● Automatically clean the inner and outer walls of the injection needle to avoid cross contamination and reduce memory effects
● Automatic stirring, easily achieving homogenization of particles and suspended solids in the sample
Intelligent human-computer interaction interface, simple and easy to use, can automatically generate reports and output data
The robotic arm automatically rotates, performs multi-point color comparison, automatically averages, eliminates measurement interference, and achieves more accurate measurements
| technical indicators | |
|---|---|
| measurement parameters | Chemical Oxygen Demand (COD) |
| Determination method | COD: 2-hour standard method and 20 minute rapid method; |
| meet the standard | COD standard: The 20 minute rapid method complies with HJ/T399-2007 "Determination of Chemical Oxygen Demand in Water Quality - Rapid Digestion spectrophotometric method"; The 2-hour standard method complies with the US Environmental Protection Agency (USEPA) 5220D standard method for ammonia nitrogen: Spectral colorimetric unit: meets the requirements of JJG178-2007 "Verification Regulations for Ultraviolet, Visible, and Near Infrared Spectrophotometers" |
| measurement range | 2-hour standard method COD: low range (3-150 mg/L); High range (20~1500 mg/L); Ultra high range (200-15000 mg/L) 20 minute rapid method COD: low range (15-150 mg/L); High range (100-1000 mg/L) |
| COD reagent is resistant to chlorine interference | Low range and high range: chloride ion<2000 mg/L; Ultra high range: chloride ions<20000 mg/L; |
| Sample size | 48 bits, supporting the expansion of sample size (optional external automatic sampler) |
| Dissolving digits | 48 digits |
| Dissolving temperature | Room temperature~190 ℃, default digestion temperature for 2-hour method program is 150 ℃, default digestion temperature for 20 minute rapid method program is 165 ℃; |
| digestion time | 2 hours or 20 minutes, or customizable digestion time |
| Dissolve temperature indication error | ±1℃; |
| Uniformity of digestion temperature | ≤3℃; |
| cooling method | Auxiliary air cooling device to accelerate the cooling and temperature reduction of the reagent tube after digestion; |
| calibration curve | The instrument is equipped with COD pre prepared reagent calibration curves of different ranges; |
| injection volume | 0-10ml, Support customization; |
| Injection accuracy | ≤1%; |
| Injection method | Direct non-contact injection technology using injection pumps; |
| Cleaning function | Automatically clean the inner and outer walls of the injection needle after injection; |
| Dilution function | Support automatic dilution function; |
| Allow sample particle size | 160 μm; |
| Multi point colorimetric measurement | Support automatic rotation of pre made reagent tubes, achieve multi-point colorimetric measurement function, and automatically calculate the average value; |
| contact method | Support data upload to LIMS system (users need to cooperate in providing data interfaces); |
| Instrument control mode | PC software for computers; |
| warning function | When the prefabricated reagent tube cannot be unscrewed, the instrument will give an alarm prompt; |
| Power requirements | AC220V±10%,50Hz,1700W |
| Working temperature and humidity | 15℃~35℃; Relative humidity ranging from 15% to 80%; |
| Instrument size | 1100 mm x 950 mm x 780 mm (length x height x depth); |
| Ordering Guide | |||
|---|---|---|---|
| 1. Instrument host and accessories | |||
| Order Number | Product Description | ||
| 2.99.VT7900 | VT-7900 fully automatic laboratory water quality analysis system (COD cr) | ||
| 2.99.901 | Instrument vehicle, compatible with instrument host, equipped with brake turning wheel | ||
| 2. Pre made reagents | |||
| Order Number | Range (mg/L) | Number of reagent tubes/tube | remark |
| 2415925-CN | 200-15000 | 25(16mm) | COD standard method (150 ℃, 2 hours) |
| 2415915-CN | 200-15000 | 150(16mm) | |
| 2125925-CN | 20-1500 | 25(16mm) | |
| 2125915-CN | 20-1500 | 150(16mm) | |
| 2125825-CN | 3-150 | 25(16mm) | |
| 2125815-CN | 3-150 | 150(16mm) | |
| 2038225-CN | 15-150 | 25(16mm) | COD rapid method (165 ℃, 20 minutes) |
| 2038215-CN | 15-150 | 150(16mm) | |
| 2038325-CN | 100-1000 | 25(16mm) | |
| 2038315-CN | 100-1000 | 150(16mm) | |