Welcome Customer !

Membership

Help

Henan Suijing Environmental Protection Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Henan Suijing Environmental Protection Technology Co., Ltd

  • E-mail

    1936867037@qq.com

  • Phone

    17395967875

  • Address

    5th Floor, Building 03, Liandong U Valley Science and Technology Innovation Valley, Qiming East Road, Yuhe District, Luoyang City, Henan Province, Suijing Environmental Protection

Contact Now

Full spectrum water quality analyzer

NegotiableUpdate on 01/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Henan Suijing Environmental Protection Technology Co., Ltd., a full spectrum water quality analyzer, was established in 2018. The company is located in Luoyang, an important industrial city in central China, and is a manufacturing and production enterprise that provides water quality analysis instruments for various industries and enterprises in Luoyang. Over the past few years, the company has adhered to the enterprise spirit of seeking truth from facts and exploring innovation, continuously advancing and rapidly growing in the water quality testing industry. The company's products are widely used in many fields such as water plants, petroleum, chemical, and food machinery manufacturing. Over the years, with professional products and a positive and enthusiastic work attitude, Suijing's footprint has spread to 30 provinces, municipalities and autonomous regions in China, and its scientific research innovation and service capabilities have rapidly improved

Product Details

全光谱水质分析仪

GNST-QGP200

Full spectrum water quality analyzer

Full spectrum water quality analyzerUsing ultraviolet radiation-Visible light absorption technology, through dual beam compensation and chemical stoichiometry algorithm analysis, obtains the corresponding pollutant content in water samples.

GNST-QGP200

Full spectrum water quality analyzer

Full spectrum water quality analyzerUsing ultraviolet radiation-Visible light absorption technology, through dual beam compensation and chemical stoichiometry algorithm analysis, obtains the corresponding pollutant content in water samples.

Application field

The instrument is widely used in industries such as surface water, sewage plant process sections, rainwater and sewage pipe networks, and river discharge outlets, and has been well received by a large number of usersrecognize.

productprinciple

Different pollutants in water have certain characteristics in terms of light absorption in different wavelength bands Sex (water quality absorption spectrum fingerprint), as shown in the following figure. full spectrum

Water quality analyzer analyzes pollutants in water bodiesThe mapping relationship between absorption spectra in the 190nm~750nm wavelength range and chemometrics is used to analyze and obtain COD, TOC, BOD, turbidity, chromaticity, and other parameters in water samples TSS、 Content of nitrate and nitrite pollutants.

Product Features
1Full spectrum detection technology, no need for reagents, no secondary pollution

2Modular design of cleaning brush, easy to replace, low maintenance cost

3Dual beam detection, automatic compensation for light source attenuation, high measurement accuracy

44 types of variable optical path blocks, fast response time, fast response in 10 seconds

Technical Specifications

Test Item

COD

TOC

BOD

nitrate

nitrite

turbidity

TSS

chroma

SAC254

range(35mmoptical path)

070mg/L

030mg/L

0~50mg/L

015mg/L

020mg/L

0200NTU

0~100mg/L

0~300Hazen

070Abs/m

range(15mmoptical path)

0~165mg/L

/

0~70mg/L

0~35mg/L

0~50mg/L

0~465NTU

0~230mg/L

0~700Hazen

0~165 Abs/m

range(5mmoptical path)

0~500mg/L

/

0~210mg/L

0~105mg/L

0~140mg/L

0~1400NTU

0~700mg/L

0~2100Hazen

0~500Abs/m

range(1mmoptical path)

0~2500mg/L

/

0~1050mg/L

0~525mg/L

0~700mg/L

0~7000NTU

0~3500mg/L

0~10500Hazen

0~2500Abs/m

model

GNST-QGP200

Measure wavelength

190nm-750nm

optical path

35mm/15mm/5mm/1mmoptional

testing indicators

CODTheTOCTheBODNitrates, nitritesturbidDegreeTSSChromaticitySAC254wait:

response time

10S

performance metrics

Accuracy: not exceeding±5.0%FS

Repeatability:2%

Zero drift: not exceeding±2%FS

automatic cleaning

Electric brushes can be set to periodically clean optical windows

interface

RS485

power supply

24VDC/10W

Operating Temperature

0~50

Protection level

IP68

Dimensions

(Φ44*533)mm



Application field

The instrument is widely used in industries such as surface water, sewage plant process sections, rainwater and sewage pipe networks, and river discharge outlets, and has been well received by a large number of usersrecognize.

productprinciple

Different pollutants in water have certain characteristics in terms of light absorption in different wavelength bands Sex (water quality absorption spectrum fingerprint), as shown in the following figure. full spectrum

Water quality analyzer analyzes pollutants in water bodiesThe mapping relationship between absorption spectra in the 190nm~750nm wavelength range and chemometrics is used to analyze and obtain COD, TOC, BOD, turbidity, chromaticity, and other parameters in water samples TSS、 Content of nitrate and nitrite pollutants.

Product Features
1Full spectrum detection technology, no need for reagents, no secondary pollution

2Modular design of cleaning brush, easy to replace, low maintenance cost

3Dual beam detection, automatic compensation for light source attenuation, high measurement accuracy

44 types of variable optical path blocks, fast response time, fast response in 10 seconds

Technical Specifications

Test Item

COD

TOC

BOD

nitrate

nitrite

turbidity

TSS

chroma

SAC254

range(35mmoptical path)

070mg/L

030mg/L

0~50mg/L

015mg/L

020mg/L

0200NTU

0~100mg/L

0~300Hazen

070Abs/m

range(15mmoptical path)

0~165mg/L

/

0~70mg/L

0~35mg/L

0~50mg/L

0~465NTU

0~230mg/L

0~700Hazen

0~165 Abs/m

range(5mmoptical path)

0~500mg/L

/

0~210mg/L

0~105mg/L

0~140mg/L

0~1400NTU

0~700mg/L

0~2100Hazen

0~500Abs/m

range(1mmoptical path)

0~2500mg/L

/

0~1050mg/L

0~525mg/L

0~700mg/L

0~7000NTU

0~3500mg/L

0~10500Hazen

0~2500Abs/m

model

GNST-QGP200

Measure wavelength

190nm-750nm

optical path

35mm/15mm/5mm/1mmoptional

testing indicators

CODTheTOCTheBODNitrates, nitritesturbidDegreeTSSChromaticitySAC254wait:

response time

10S

performance metrics

Accuracy: not exceeding±5.0%FS

Repeatability:2%

Zero drift: not exceeding±2%FS

automatic cleaning

Electric brushes can be set to periodically clean optical windows

interface

RS485

power supply

24VDC/10W

Operating Temperature

0~50

Protection level

IP68

Dimensions

(Φ44*533)mm