Henan Suijing Environmental Protection Technology Co., Ltd., a full spectrum water quality analyzer, was established in 2018. The company is located in Luoyang, an important industrial city in central China, and is a manufacturing and production enterprise that provides water quality analysis instruments for various industries and enterprises in Luoyang. Over the past few years, the company has adhered to the enterprise spirit of seeking truth from facts and exploring innovation, continuously advancing and rapidly growing in the water quality testing industry. The company's products are widely used in many fields such as water plants, petroleum, chemical, and food machinery manufacturing. Over the years, with professional products and a positive and enthusiastic work attitude, Suijing's footprint has spread to 30 provinces, municipalities and autonomous regions in China, and its scientific research innovation and service capabilities have rapidly improved

GNST-QGP200
Full spectrum water quality analyzer
Full spectrum water quality analyzerUsing ultraviolet radiation-Visible light absorption technology, through dual beam compensation and chemical stoichiometry algorithm analysis, obtains the corresponding pollutant content in water samples.
GNST-QGP200
Full spectrum water quality analyzer
Full spectrum water quality analyzerUsing ultraviolet radiation-Visible light absorption technology, through dual beam compensation and chemical stoichiometry algorithm analysis, obtains the corresponding pollutant content in water samples.
Application field
The instrument is widely used in industries such as surface water, sewage plant process sections, rainwater and sewage pipe networks, and river discharge outlets, and has been well received by a large number of usersrecognize.
productprinciple
Different pollutants in water have certain characteristics in terms of light absorption in different wavelength bands Sex (water quality absorption spectrum fingerprint), as shown in the following figure. full spectrum
Water quality analyzer analyzes pollutants in water bodiesThe mapping relationship between absorption spectra in the 190nm~750nm wavelength range and chemometrics is used to analyze and obtain COD, TOC, BOD, turbidity, chromaticity, and other parameters in water samples TSS、 Content of nitrate and nitrite pollutants.
Product Features
(1)Full spectrum detection technology, no need for reagents, no secondary pollution
(2)Modular design of cleaning brush, easy to replace, low maintenance cost
(3)Dual beam detection, automatic compensation for light source attenuation, high measurement accuracy
(4)4 types of variable optical path blocks, fast response time, fast response in 10 seconds
Technical Specifications
Test Item |
COD |
TOC |
BOD |
nitrate |
nitrite |
turbidity |
TSS |
chroma |
SAC254 |
range(35mmoptical path) |
0~70mg/L |
0~30mg/L |
0~50mg/L |
0~15mg/L |
0~20mg/L |
0~200NTU |
0~100mg/L |
0~300Hazen |
0~70Abs/m |
range(15mmoptical path) |
0~165mg/L |
/ |
0~70mg/L |
0~35mg/L |
0~50mg/L |
0~465NTU |
0~230mg/L |
0~700Hazen |
0~165 Abs/m |
range(5mmoptical path) |
0~500mg/L |
/ |
0~210mg/L |
0~105mg/L |
0~140mg/L |
0~1400NTU |
0~700mg/L |
0~2100Hazen |
0~500Abs/m |
range(1mmoptical path) |
0~2500mg/L |
/ |
0~1050mg/L |
0~525mg/L |
0~700mg/L |
0~7000NTU |
0~3500mg/L |
0~10500Hazen |
0~2500Abs/m |
model |
GNST-QGP200 |
Measure wavelength |
190nm-750nm |
optical path |
35mm/15mm/5mm/1mmoptional |
testing indicators |
CODTheTOCTheBODNitrates, nitritesturbidDegreeTSSChromaticitySAC254wait: |
response time |
≤10S |
performance metrics |
Accuracy: not exceeding±5.0%FS;
Repeatability:≤2%;
Zero drift: not exceeding±2%FS;
|
automatic cleaning |
Electric brushes can be set to periodically clean optical windows |
interface |
RS485 |
power supply |
24VDC/10W |
Operating Temperature |
0~50℃ |
Protection level |
IP68 |
Dimensions |
(Φ44*533)mm |
Application field
The instrument is widely used in industries such as surface water, sewage plant process sections, rainwater and sewage pipe networks, and river discharge outlets, and has been well received by a large number of usersrecognize.
productprinciple
Different pollutants in water have certain characteristics in terms of light absorption in different wavelength bands Sex (water quality absorption spectrum fingerprint), as shown in the following figure. full spectrum
Water quality analyzer analyzes pollutants in water bodiesThe mapping relationship between absorption spectra in the 190nm~750nm wavelength range and chemometrics is used to analyze and obtain COD, TOC, BOD, turbidity, chromaticity, and other parameters in water samples TSS、 Content of nitrate and nitrite pollutants.
Product Features
(1)Full spectrum detection technology, no need for reagents, no secondary pollution
(2)Modular design of cleaning brush, easy to replace, low maintenance cost
(3)Dual beam detection, automatic compensation for light source attenuation, high measurement accuracy
(4)4 types of variable optical path blocks, fast response time, fast response in 10 seconds
Technical Specifications
Test Item |
COD |
TOC |
BOD |
nitrate |
nitrite |
turbidity |
TSS |
chroma |
SAC254 |
range(35mmoptical path) |
0~70mg/L |
0~30mg/L |
0~50mg/L |
0~15mg/L |
0~20mg/L |
0~200NTU |
0~100mg/L |
0~300Hazen |
0~70Abs/m |
range(15mmoptical path) |
0~165mg/L |
/ |
0~70mg/L |
0~35mg/L |
0~50mg/L |
0~465NTU |
0~230mg/L |
0~700Hazen |
0~165 Abs/m |
range(5mmoptical path) |
0~500mg/L |
/ |
0~210mg/L |
0~105mg/L |
0~140mg/L |
0~1400NTU |
0~700mg/L |
0~2100Hazen |
0~500Abs/m |
range(1mmoptical path) |
0~2500mg/L |
/ |
0~1050mg/L |
0~525mg/L |
0~700mg/L |
0~7000NTU |
0~3500mg/L |
0~10500Hazen |
0~2500Abs/m |
model |
GNST-QGP200 |
Measure wavelength |
190nm-750nm |
optical path |
35mm/15mm/5mm/1mmoptional |
testing indicators |
CODTheTOCTheBODNitrates, nitritesturbidDegreeTSSChromaticitySAC254wait: |
response time |
≤10S |
performance metrics |
Accuracy: not exceeding±5.0%FS;
Repeatability:≤2%;
Zero drift: not exceeding±2%FS;
|
automatic cleaning |
Electric brushes can be set to periodically clean optical windows |
interface |
RS485 |
power supply |
24VDC/10W |
Operating Temperature |
0~50℃ |
Protection level |
IP68 |
Dimensions |
(Φ44*533)mm |