4、 ATR design:
Diamond ATR accessories, pure diamond crystals, high strength, super corrosion resistance, large crystal size, high luminous flux, excellent sensitivity. Compatible with various infrared spectrometers both domestically and internationally. This attachment has a wide application market and can meet the testing needs of different industries such as organic matter, superhard polymers, inorganic matter, minerals, stones, asphalt, and various composite materials.

5 FOLI10Fourier transform infrared spectrometerSpecial applications:
1. Gas detection: can be applied to real-time detection of environmentally friendly gases and industrial online gases, providing mature gas online analysis applications for ethylene glycol process systems;
2. Public security riot control and drug enforcement: can be applied to component identification of unknown substances;
3. Lubricating oil: identification of genuine and fake oil products, quality control of raw materials and products, quality testing of in use oil, differentiation of manufacturers, etc;
4. Jewelry and Jade: Testing Applications in the Cultural and Creative Industries as well as the Jewelry and Jade Industry.
5. Application in the field of criminal investigation and drug control:
(1) Criminal investigation: rapid analysis and detection of explosives at the scene, and rapid evidence collection of dangerous goods at the scene.
(2) Drug enforcement: identification and analysis, screening of new counterfeit products.
With the rapid development of science and technology, there has been tremendous progress in all aspects of society. Science and technology also play an important role in solving various cases. In the field of anti drug analysis, the application of infrared spectroscopy technology has greatly improved the shortcomings of previous analysis techniques such as explosives, providing favorable evidence for the investigation of anti drug cases.
Different components exhibit different vibration frequencies in infrared spectra, and the application of infrared spectroscopy technology to analyze such substances can detect specific components. Different harmful substances exhibit different peak positions in the infrared spectrum, making it easy to identify their types from the spectrum. Infrared spectroscopy technology is used for drug detection and has the characteristics of simple operation, no use of harmful reagents, no contamination of test materials, small sample size, and accurate results. Therefore, infrared spectroscopy technology is a very simple and effective method for distinguishing species. It can be expected that the application of infrared spectroscopy technology in the field of drug detection will become increasingly widespread.
6、 FOLI10 Fourier Transforminfrared spectrometerCharacteristics for use in the field of drug detection:
1. Short on-site testing and analysis time (no need to wait for laboratory test results);
2. Easy to use, user-friendly, and simple operating interface, no need for professional training, directly on duty;
3. Without the need for professional background operators, sample components can be analyzed intuitively and accurately;
4. No need for sample preparation, direct on-site analysis;
5. New type of data networking, real-time updates and upgrades. Extremely fast, convenient, and simple;
6. Can quickly identify explosives, prohibited items, general drugs, etc;
7. On site inspection greatly saves costs (expenses and time), which is both efficient and fast;
7、 Application in the fields of environmental protection and special gas detection:
With the rapid development of science and technology, FTIR technology has been widely applied in fields such as environmental monitoring, environmental chemistry, and emergency response to sudden environmental pollution accidents. The infrared gas online monitoring system performs real-time detection of gaseous pollutants in the flue gas system, such as H2O, NOX (NO2, NO, N2O), HF, SO2, CO, HCl, NH3, and CO2. The infrared gas online monitoring system monitors the types and concentrations of particulate matter and gaseous pollutants in the air through an infrared spectrometer, and continuously monitors the pollutants emitted in the air. In addition, it also manages and monitors environmentally friendly equipment such as dust collectors and desulfurization and deacidification equipment.
8、 The outstanding features of FOLI10 for gas detection are:
1. No need for analyzer pre sample adjustment unit, no need for nitrogen calibration;
2. Advanced stereo angle mirror design interferometer, with long-term collimation of the optical path and excellent stability;
3. ZnSe material beam splitter and window, suitable for field and industrial use, to prevent optical components from deliquescence;
4. Gas cells with different optical paths can be configured according to the actual requirements of users to meet the measurement needs of different concentrations;
5. Built in heating pipeline and heating probe controller, connected to FTIR signal;
6. Optional mass flow controller for high concentration analyte injection and linear calibration;
7. Data can be downloaded or uploaded to cloud servers for remote analysis of experimental results, and new gases can be reanalyzed offline;
8. Equipped with a highly sensitive DLaTGS sensor, it can operate at ambient temperatures without the need for liquid nitrogen or other cooling devices. Optional semiconductor refrigeration MCT detector;
9. The Foli10 multi-component gas analyzer can be placed on laboratory platforms or provided with a portable mobile box for monitoring purposes;
9、 FOLI10 Other related application areas:
1. Environmental emergency monitoring
2. On site monitoring of labor hygiene
3. Industrial Process Analysis and Control
4. Research on Catalytic Conversion Science
5. Smoke exhaust gas testing
6. Monitoring of gas emissions from garbage incineration and combustion
7. Especially suitable for:
(1) Simultaneously analyze multiple components
(2) High temperature and high humidity of the tested gas
(3) The composition of the tested gas is complex
(4) Rigorous testing environment