characteristic
One year warranty
Adopting intelligent thin film correction(IQMC)Technology, no need for calibration
C2Light speed correction, high measurement accuracy
Green light technology(GLT)The fluorescent cap has a long lifespan
Equal optical path reference system(EPRS)Stable measurement without drift
45Degree design, not affected by bubbles
Unfilled electrolyte
No minimum flow rate requirement
working principle:
A layer of fluorescent dye is covered on the thin film at the top of the sensor. When a short wavelength light is irradiated onto the fluorescent dye, it emits long wavelength red light when it returns from the excited state to the ground state. The red light is the test signal. The higher the concentration of dissolved oxygen, the shorter the duration of red light. By testing the duration of red light, the concentration of dissolved oxygen can be determined. The first generation of fluorescence based dissolved oxygen sensors had the following drawbacks:
The longer the film is in contact with water, the greater the signal drift
Fluorescent dyes are prone to aging after exposure to blue light
Sensors are more sensitive to bubbles
WTWrely on60Years of manufacturing experience have successfully overcome the above difficulties and launched the second-generation fluorescence based dissolved oxygen sensor. The technological advantages of second-generation sensors are mainly reflected in the following aspects:
IQMCtechnology:Each diaphragm undergoes strict calibration before leaving the factory, and the calibration data is stored in the chip on the diaphragm.
EPRSEqual optical path reference system:The test optical path and reference optical path, as well as the complete symmetry of the optical path system, can synchronously eliminate the influence of optical component aging. Ensure high testing accuracy within the lifespan of the sensor.
GLTGreen light technology:Green light has relatively less energy compared to blue light, which can avoid the fading effect of fluorescent dyes and extend the service life of the film, usually achieving2Years of lifespan.
45Degree testing technology:The top of the sensor does not adopt a flat structure, but has a45The slope of the degree can avoid the accumulation of bubbles, thus solving the problem of the first generation being easily disturbed by bubbles.
C2Light speed correction calibration:The fluorescence method ultimately boils down to the issue of testing time, thereforeWTWThe time testing system is strictly calibrated according to the physical constant of light speed, ensuring accurate time testing.
|
|
|
|
|
|
|
|
|
sensor structure
Storage chip
There is a storage chip on the fluorescent cap of the sensor that can store the following data: fluorescent cap type, serial number, and factory calibration data.
IQMCtechnology
Each fluorescent film undergoes strict calibration before leaving the factory, and the calibration data is permanently stored on a chip to ensure the accuracy of the sensor during use.
Outline dimension diagram
Technical Parameter
|
model |
FDO 700(SW) |
FDO 701(SW) |
|
test method |
green lightfluorescence |
|
|
Range(25℃) |
O2concentrated linear measure:0 …20.00 mg/l、O2saturation:0.0…200.0% |
|
|
Resolution |
O2concentrated linear measure:0.01 mg/l、O2saturation:0.1% |
|
|
measurement accuracy |
< 1mg/lWhen is0.05 mg/l、>1mg/lWhen is0.1mg/l |
|
|
Repeatability |
+/- 0.05 mg/l |
|
|
reaction timeat 25℃ |
t90<150 s,t95<200 s |
t90<60 s,t95<80 s |
|
Minimum flow velocity |
No requirements |
|
|
Electrode inspectionSensor Check |
Thin film monitoring function |
|
|
sensorcorrectrecord |
Yes, factory calibration |
|
|
Power consumption |
0.7tile |
|
|
Temperature test |
-5℃…+60℃,built-inNTCprobe |
|
|
temperature compensation |
-5℃…+50℃ |
|
|
Voltage resistance |
10hope earnestly(Including sensor cable) |
|
|
Surrounding environment |
work: -5℃…+50℃ |
work: -5℃…+40℃ |
|
Connector |
2Core shielded wire,IQSpecial connector |
|
|
Input power supply |
IQ Sensor Netpower supply |
|
|
Lightning protection circuit |
have |
|
|
EMI/RFIprotection |
EN 61326, Class B, FCC Class A, |
|
|
Certification |
CE, cETLus |
|
|
Construction |
Film head:POM, PVC, silicone rubber;Electrode body: stainless steel,IP68 |
|
|
Size |
400X40 mm SW: 400X59.5 mm |
|
|
Weight |
make an appointment900can SWmake an appointment1500g |
|
|
Fluorescent cap lifespan* |
24Month |
6Month |
|
Sensor warranty period |
Two years, in compliance§ 10 AGBcondition |
|
|
Ordering Information |
||
|
model |
describe |
order No |
|
FDO ® 700 IQ |
Fluorescence dissolved oxygen sensor, sewage detection, including fluorescent capSC-FDO 700 |
201650 |
|
FDO ® 700 IQ SW |
Fluorescence dissolved oxygen sensor, seawater detection, including fluorescent capSC-FDO700And protective coverMSK FDO |
201652 |
|
FDO ® 701 IQ |
Fluorescent dissolved oxygen sensor, rapid response type, including fluorescent capSC-FDO701 |
201660 |
|
FDO ® 701 IQ SW |
Fluorescent dissolved oxygen sensor, rapid response type, including fluorescent capSC-FDO 701And protective coverMSK FDO |
201660 |
|
SC-FDO ® seven hundred |
Universal fluorescent cap, suitable forFDO 700/ 700SW |
201654 |
|
SC-FDO ® seven hundred and one |
Fluorescent cap with fast response time, suitable forFDO 701/ 701SW |
201655 |
|
MSK FDO |
Protective cover |
205253 |
|
MSK FDO ® CS |
Cleaning equipment and protective coversMSK FDOsimultaneous use |
205254 |
SW: Sea WaterApplication of seawater;SACIQfor a special purposecableOrder separately FDO700IQ online fluorescence dissolved oxygen sensor FDO700IQ online fluorescence dissolved oxygen sensor FDO700IQ online fluorescence dissolved oxygen sensor