The FCA500A contact angle measuring instrument is mainly used to measure the contact angle between liquid and solid, that is, the wettability of liquid to solid, and can also measure the contact angle when the external phase is liquid. This instrument can measure the contact angle of various liquids with various materials, such as block materials, fiber materials, textile materials, nanomaterials, semiconductor materials, silicon wafer materials, etc. Powder samples can also be measured after compression. At the same time, this series of instruments can measure and calculate liquid surface/interfacial tension and solid surface free energy. When a droplet is freely in a space unaffected by a force field, it takes on a spherical shape due to the presence of interfacial tension. However, when a droplet comes into contact with a solid plane, its final shape depends on the relative strength of the internal cohesion of the droplet and the adhesion between the droplet and the solid. When a droplet is placed on a solid surface, it can automatically spread out on the solid surface or exist as a droplet at a certain contact angle with the solid surface. Contact angle measuring instruments have important applications in improving oil extraction rates, flotation of target minerals, clean coal processing, biopharmaceutical materials, semiconductor chip industry, and characterization of non-toxic low surface energy anti fouling materials. In addition, contact angle measurement technology also has important applications in characterizing industries such as ink, cosmetics, pesticides, printing and dyeing, papermaking, fabric finishing, detergents, spraying, and wastewater treatment.

The FCA500A contact angle measuring instrument meets the standard:
GB/T 23436-2009 Automotive Windshield Cleaning Fluid
GB/T 24368-2009 Glass Surface Hydrophobic Contaminants Detection Contact Angle Measurement Method
GB/T 24622-2009 Guidelines for Measuring Surface Wettability of Insulators
ISO 15989-2004 Measurement of water contact angle of plastic film and thin plate corona treated film
ASTM C 813-1990 (2004) Standard Test Method for Detecting Hydrophobic Contaminants on Glass Surfaces Using Contact Angle Measurement
ASTM D 5946-2009 Standard Test Method for Corona Treatment of Polymer Films Using a Water Contact Angle Measuring Instrument
ASTM D 7334-2008 (2013) Standard Test Method for Wettability of Coating, Substrate, and Pigment Surfaces Using Forward Contact Angle Measurement
ASTM D 7490-2013 Standard Test Method for Measuring Surface Tension of Solid Coatings, Substrates, and Pigments Using Contact Angle
ASTM G 205-2010 Standard Guide for Determining the Corrosivity of Crude Oil
ASTM D 724-1999 (2003) Standard Test Method for Surface Wettability of Paper (Contact Angle Method)
ASTM D 5725-1999 (2008) Standard Test Method for Surface Moisture and Absorption of Covering Materials Using an Automatic Contact Angle Tester
Wettability of TAPPI T 458 CM-2004 Paper Surface (Contact Angle Method)
SY/T 5153-2007 Determination Method for Wettability of Reservoir Rocks
YC/T 424-2011 Determination of Surface Wettability of Tobacco Paper by Contact Angle Method

FCA500A contact angle measuring instrument parameter indicators:
Sample table size: diameter 400mm with graduated disc
Sample stage movement range: X-axis 200mm, accuracy 0.1mm; rotation axis 360 degrees, accuracy 0.001 degrees; Z-axis 45mm, accuracy 0.1mm
Contact angle measurement range: 0-180 °
Contact angle display accuracy: ± 0.01 °
Contact angle measurement accuracy: ± 0.1 °
Surface/Interface Tension Measurement Range: 0-2000mN/m (Suspension Drop Method, Lying Drop Method)
Surface/interface tension display accuracy: 0.01mN/m
Surface free energy methods: One liquid method, Owen's two liquid method, three liquid method, and other multiple methods can be selected
Optical system: 0.7X-5X high-definition positioning variable magnification lens, front 20X objective lens for measuring ultra-fine fiber contact angle
Optical lens movement stroke: XY axis: ± 6.25mm
Optical lens top-down adjustment: ± 6.5 °
Light source system: 60x60cm LED adjustable monochrome cold light source/fiber contact angle measurement dedicated light source
Video system: USB 3.0 camera+PC soft control 54 frames per second
Video capture method: manual capture, automatic capture, freely set capture speed, interval time of 0.1-3600sec, AVI recording
Injection injection system movement mode: high-precision industrial automatic injection pump, stroke 25mm, accuracy ± 0.01mm
Injection droplet control accuracy: 0.01 μ l~5 μ l
Measurement software: AFES20.1.0
Measurement function: dynamic and static contact angle, forward and backward angle, measuring rolling angle
Measurement methods: Angle measurement method, three-point height measurement method, one point penetration method, automatic measurement method, geometric fitting method, and other methods are available for selection
Measurement correction: Surface correction, concave convex contact angle measurement, fiber coated droplet correction
Measurement temperature: room temperature
Data processing: Compare and calculate the left and right corners, take the average, automatically save images and data to the database, export to Excel, and print reports
Instrument material: Plastic imported aviation aluminum, fine surface oxidation treatment
Instrument motion structure: The overall structure of the instrument includes eight dimensional motion adjustment modes
Instrument expansion: Reserved expansion interface, modular and upgradable
Instrument dimensions: 960mm * 560mm * 700mm
Instrument weight: 25Kg
Power supply: 220V 3A50Hz
After sales service: Free software upgrade, free home delivery for installation and debugging in mainland China, unconditional one-year warranty, conditional three-year warranty
FCA500A Contact Angle Measuring Instrument Warranty:
The company provides on-site training on installation, debugging, operation, and maintenance. When there is a problem with the instrument, a response must be received from the user within 24 hours. If on-site handling is required, confirmation must be made within 72 hours. Free warranty for 1 year from the date of acceptance, conditional warranty for 3 years, and lifetime maintenance. This clause is only applicable to domestic users.