- Phone
-
Address
Room 601, No. 23, Lane 1288, Xinyuan Road, Jiading District, Shanghai
Shanghai Ruidan Automation Instrument Co., Ltd
Room 601, No. 23, Lane 1288, Xinyuan Road, Jiading District, Shanghai
External mounted clamp type ultrasonic flowmeterIt is a measuring device installed on pipelines for non-invasive purposesMeasure the flow rate of a fluid in a standardized manner. It emits ultrasonic pulses and is received by a receiver after passing through the fluidCollect and then calculate the flow rate and flow rate. The advantage of this flowmeter is that it does not generate pressure lossShutdown installation is required, and accurate measurements can be taken for different fluids.
External mounted clamp type ultrasonic flowmeterapplication fieldIndustrial process monitoringCard mounted ultrasonic flow meters are widely used in semiconductor, fine chemical, and cleaning industriesUsed for real-time monitoring of liquid flow in the washing industry, beverage and food industries, and other industrial processesWater treatment and distributionIn water treatment plants and water supply systems, this flowmeter is used for precise measurementAnd control the distribution of water to ensure the stability of water quality and flow rate.Laboratory monitoringUsed for measuring the flow rate of small liquid diameters in laboratories, helping laboratories toConduct experimental proportioning.External mounted clamp type ultrasonic flowmeterMeasuring principleUltrasonic flowmeter measurement is based on time difference method, using two ultrasonic sensors facing each other3Sending and receiving ultrasonic waves, indirectly by observing the time difference between the forward and backward propagation of ultrasonic waves in the mediumMeasure the flow velocity of the fluid and calculate the flow rate based on the flow velocity.a chapterProduct features1.1 Product advantagesHigh precision:The clamp type ultrasonic flowmeter adopts digital signal processing technology, which can achieveHigh precision flow measurement.Strong reliability:The flow meter adopts ultrasonic technology, which has strong reliabilityPoint, able to work stably for a long time.Easy to installClamp type ultrasonic flowmeter does not require shutdown installation, only needs to be installed in the pipelineJust install it, it's very convenient to install.Low maintenance costsThe caliper style design makes daily maintenance more convenient and reduces long-term maintenanceProtection costs and labor intensity.Strong adaptability:Clamp type ultrasonic flowmeter is suitable for various fluids, including corrosive liquidsBody and high-temperature fluids have high adaptability.1.2 measurement rangeFlow velocity measurement range:The card mounted ultrasonic flowmeter can measure a wide range of flow rates, fromBoth low-speed and high-speed fluids can be accurately measured.Caliber adaptation range:This flowmeter is designed flexibly and can adapt to pipelines of different diameters, fromDN10-125 pipelines can be used.Temperature applicable range:Flow meters can operate stably over a wide temperature range and are typically suitable for-Fluid temperature environment ranging from 20 ℃ to+100 ℃.33 1.3 accuracy classMeasurement accuracy:The measurement accuracy of card mounted ultrasonic flow meters is usually within ± 1% FS, ensuringThe reliability of the measurement results.repetitivenessThis flowmeter has high repeatability (0.2%), even under different flow conditions,It can also ensure the consistency and accuracy of measurement data.1.4 working conditionstemperature rangeThe card mounted ultrasonic flowmeter can operate stably within the temperature range of -20 ℃ to+60 ℃,Adapt to various environments.Pressure limitThis flowmeter is designed to be unaffected by working pressure, ensuring accuracy in high-pressure environmentsAccurate measurement.Fluid typeSuitable for clean, low viscosity liquids such as water, oil, organic solutions, etc., not applicableFor fluids containing a large number of bubbles or solid particles.Chapter 2 Technical ParametersProduct modelUSFM-KCflow range0.1m/s~5.0m/saccuracyDN20 or above, ± 1.0% (>0.3m/s); Below DN15 ± 2%;repetitivenessDN20 or above, 0.2%; Below DN15, 0.4%Measure the pipe diameterDN10 ~ DN653 Storage functionAccumulated daily, monthly, and annual traffic volumeanalog output4~20mA, Large load 400 Ωalarm outputOCT upper and lower limit alarm function, relay output (optional)communication interfaceRS485, Supports Modbus communication protocolpower supply10~36VDC,<3Wcable lengthStandard 2 meters, other lengths need to be customized in advancekeyboardFour touch buttonsLanguage menuChinese display, EnglishdisplayLCD 128 * 64 dot matrix displayunitSupport the selection of metric and imperial units such as Cubic, Peters (m3), Liters (L),USA Gallons(GAL), m³/h、m³/m、m³/s、L/h、L/m、L/s, The default unit at the factory is m3/hdisplay dataInstantaneous flow rate, instantaneous flow velocity, net cumulative amount, single cumulative amount, historical data queryinquireAccumulator7-bit traffic accumulatorSuitable for pipesStainless steel, carbon steel, copper pipe, plastic pipeShell materialaluminum alloyambient temperature-20℃~60℃medium temperature0 ℃~70 ℃ (split up to 160 ℃), high-temperature coupling adhesive needs to be separately configuredambient humidityRelative humidity 0~95%, no condensationflow range0.1m/s~5.0m/sProtection levelIP545 watch1 Common traffic range (by.5m/s~5m/sCalculation)Table of Caliber and Common Flow Rangenominal diameterDN8DNI 0DN12DN15DN20theoretical inner diameter(mm)8 10 12 15 20 wall thickness(mm)2~42~42~42~42~4Corresponding to the theoretical inner diameterCalibrate flow range(m³/h)0.09-0.9 0.14~1.41 0.20~2.0 0.3~3.00.57~5.7Corresponding to the theoretical inner diameterCalibrate flow range(L/min)1.5~152.3~233.4~345~509.5-95Table of Caliber and Common Flow Rangenominal diameterDN25DN32DN40DN50DN65theoretical inner diameter(mm)25 32 40 50 65 wall thickness(mm)3-63-63~63~63~6Corresponding to the theoretical inner diameterCalibrate flow range(m³/h)0.88-8.8 1.4~14.02.2~223.5~356~60Corresponding to the theoretical inner diameterCalibrate flow range(L/min)14.6~146 23.3~233 36.6~366 58.3~583 100~ 10005 Chapter 3 Product Structure and Dimensionspicture2 Product Dimension DrawingcategoryApplication caliber rangecritical dimension(mm)weight(kg)DNouter diameterABCDEFGnet weightUSFM-KC-108~1512~18 4452 31 42 101 11028 0.42 USFM-KC-2015~2018~28 4452 31 42 101 11028 0.42 USFM-KC-3225~3228~4466 7554 42 101 11050 0.62 USFM-KC-5040~5044~6492 101 80 42 101 11077 0.84 USFM-KC-6565 65~7692 101 80 42 101 11077 0.845 Table 3 Product Size Table3.1 Selection IntroductionHow to choose?Based on the outer diameter,If the inner diameter is the main factor, the signal cannot be tested when the wall thickness is relatively thick.Assuming an outer diameter of 21, a wall thickness of 5.5, and an inner diameter of 10mm, choose USFM-KC-20 instead ofUSFM-KC-10。The recommended sensor model is to chooseIf the outer diameter is 17mm, both USFM-KC-10 and USFM-KC-20 can be used,But priority should be given to USFM-KC-10.USFM-KC-65Suitable for DN65 inner diameter pipelines, currently the maximum wall thickness tested is 5.5mm.3.2 Sensor installation locationChoosing the installation point is crucial for accurate measurement, and the following factors must be considered when selecting the installation pointEffects: Full pipe, steady flow, vibration, scaling, temperature, pressure, electromagnetic interference, etc.