External clamp flowmeter

NegotiableUpdate on 06/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

External clamp flowmeter, bundled installation, DN20-3000, There are large, medium, and small probes to protect the pipeline and facilitate installation.

Product Details


External clamp flowmeterAlso known as external flow meter, clamp type flow meter, bundled installation, no need to damage pipelines, easy installation, high measurement accuracy.

★ Pressure resistance level: not affected by the pressure of the medium inside the pipeline, suitable for measuring the flow rate of the medium under all working pressures

★ Medium used: All uniformly distributed within the pipelineliquidmedium

★ Usage requirements: The medium fluid flows through the pipeline evenly and completely without impurities, DN25-800, Limited to liquids only

★ Advantages: External clamp type (external application type) installation, no need to damage the pipeline, ensuring the integrity of the pipeline, accuracy of 1.0, displaying instantaneous flow and cumulative flow, outputting 485, 4-20mA signals, PVC pipes, steel pipes can be lined to meet measurement needs, especially suitable forhigh pressureThe Conduit.

外夹式流量计V法安装

外夹式流量计Z法安装

外夹式流量计外形尺寸

External clamp flowmeterSuitable for flow measurement of various sizes of pipelines, with a flow velocity measurement range of 0.01 to ± 32m/s. The measuring medium is a single stable liquid such as water, seawater, sewage, alcohol, etc. The measuring materials are steel, stainless steel, cast iron, etc PVC、 Uniformly dense pipelines such as fiberglass.

Measurement accuracy: 1%;

Working power supply: isolated DC8-36V or AC85-264V;

Power consumption: Operating current of 50mA (without connecting keyboard and buzzer);

Optional output: 1 road brick isolated RS485 output; 1 isolated 4-20mA or 0-20mA output (active or passive optional); Optional HART protocol; Dual channel isolated OCT output (OCT1 pulse width between 6-1000ms programmable, default 200ms); 1 bidirectional serial peripheral universal interface, which can directly connect multiple external devices such as 4-20mA analog output board, frequency signal output board, thermal printer, data recorder, etc. through serial connection;

Optional input: Three 4-20mA analog input circuits;

Display: 2 × 10 Chinese character backlit display (bilingual options available in Chinese and English);

Operation: Window based operation with 16 or 4 buttons;

Other functions: Automatically remember the first 512 days, the first 128 months, and the positive and negative net cumulative flow of the first 10 years. Automatically remember the first 30 power on and off times and flow rates, and can achieve automatic or manual replenishment. It can also be read out through the MODBUS protocol;

Flow sensors: external application, insertion, and pipe segment;

performance parameter

project

Performance and parameters

Measurement host (primary meter)

accuracy

1%

repeatability

0.2%

Maximum flow rate

64m/s

Measurement period

200mS (5 times per second, 128 sets of data collected per cycle)

measuring principle

Ultrasonic Time Difference Principle, 4-byte IEEE754 Floating Point Operation

display interface

Connectable2 × 10 backlit Chinese characters or 2 × 20 character LCD display

operate

External 16 key touch keyboard and PC computer parameter software

input

3-channel 4-20mA input is optional, with an accuracy of 0.1%. It can input signals such as pressure, liquid level, temperature, etc., and can also be used as a digital interface.

Two way three wire PT100 platinum resistor input circuit, capable of achieving heat metering function (enthalpy difference method)

output

Current signal (optional module): 4~20mA, impedance 600ΩFloating, with an accuracy of 0.1%.

Frequency signal (optional module): Choose between 1~9999Hz, OCT output.

Pulse signal: positive, negative, net flow and heat accumulation pulses, dual OCT output (with one pulse width programmable between 6-1000ms, default 200ms).

Alarm signal: Dual OCT output, with up to 20 selectable source signals.

Data interface: Isolated RS485 serial interface.

Communication protocol

MODBUS protocol, MBUS protocol, FUJI extension protocol (compatible with communication protocols for flow meters and water meters of Huizhong Company), it is recommended to use MODBUS-RTU protocol or MODBUS-ASCII protocol

Other functions

Automatically remember the accumulated traffic and work status of the previous 64 days, 32 months, and 2 years; Automatically remember the first 16 power on/off times and flow rate, and can achieve automatic or manual replenishment;

Programmable quantitative controller (can be started using external input signals or MODBUS commands);

One bidirectional serial interface can connect multiple external devices such as 4-20mA and data loggers;

The working parameters can be fixed in the FLASH memory inside the machine and automatically retrieved when powered on;

Users can upgrade software by sending code files via email

Fault self diagnosis function.

Fault time timer.

Working current

50mA (without connecting keyboard display and buzzer not sounding)

Stand-by current

Using CR2032, maintain 100000 hours of data without loss under 24VDC power outage conditions

ambient temperature

-10℃~70 ℃ (please contact the manufacturer if the temperature range exceeds this requirement)

working hours

continuous

VERSION

WLV12

WLV13

WLV14

WLV15

power supply

24VDC

8~30VDC

24VDC

85~264VAC/24VDC

Size (mm)

Φ84

116×62

936

15095

sensor

External binding type

Standard S1 type, suitable for pipe diameter DN15~100mm

Standard M1 type, suitable for pipe diameter DN50~700mm

Standard L1 type, suitable for pipe diameters ranging from DN300 to 6000mm

High temperature S1H type, suitable for pipe diameter DN15~100mm

High temperature M1H type, suitable for pipe diameter DN50~700mm

Sensors from other manufacturers

plug-in

The material of the measuring pipeline is not limited (for non-stop installation) and is suitable for pipes with a diameter of DN80 or above.

Pipe section type

πType pipe segment: suitable for pipe diameterDN25~DN40, The measurement accuracy of the whole machine is ± 0.5%

Standard pipe section: suitable for pipe diameterDN50~DN1000, The measurement accuracy of the whole machine is ± 0.5%

signal cable

Special SEYV75-2 shielded twisted pair cable, factory standard 5 meters, can be extended up to 500 meters for specific occasions (not recommended).

protection grade

IP68 (capable of working in water immersion)

Measurable pipeline

Pipe

Steel, stainless steel, cast iron PVC、 Copper, aluminum, cement pipes, and other materials with dense texture are allowed to have lining.

Lining material

Epoxy asphalt, rubber, mortar, polypropylene, polystyrene, polyester, polyethylene, hard rubber, rubberwood, polytetrafluoroethylene.

inside diameter

15mm~6000mm(πThe inner diameter of the segmented pipe can be as small as 2 millimeters

Length of straight pipe section

Upstream ≥ 10D, downstream ≥ 5D, distance from pump outlet ≥ 30D.

Measurable pipeline

type

Uniform liquids that can propagate ultrasonic waves, such as water, seawater, acidic and alkaline liquids, food oil, gasoline, coal, diesel, crude oil, alcohol, beer, etc.

turbidity

≦20000ppm, The sewage measurement results are good, and the vast majority of sewage pipelines can be stably measured.

temperature

-40℃~160℃

flow direction

It can measure the forward and reverse flow separately and measure the net flow.

Sensor specifications and usage:

外夹式流量计传感器规格

sensor

Standard S1 type

Standard M1 type

Standard L1 type

High temperature S1H type

High temperature M1H type

Applicable pipe diameter

DN15-DN100

DN50-DN700

DN300-DN6000

DN15-DN100

DN50-DN700

liquid temperature

0℃~70℃

0℃~160℃

Installation positionTo ensure measurement accuracy and stability, the installation point of the sensor should be selected in the straight pipe section with uniform flow field distribution (the pipeline must be filled with liquid during normal use). The following principles must be followed:

Select the position of the full pipe, such as a straight pipe section (where fluid flows upwards) or a horizontal pipe section.
外夹式流量计安装方式1
The installation point should choose a straight pipe section with no valves, elbows, or reducers within 10 times the diameter of the straight pipe upstream and 5 times the diameter of the straight pipe downstream. The installation point should be sufficiently far away from interference sources such as valves, pumps, high-voltage electricity, and frequency converters.
外夹式流量计安装方式2
Avoid installation at the highest point of the pipeline system or on vertical pipelines with free outlets (where fluid flows downwards)
外夹式流量计安装方式3
For open or semi full pipes, flow meters should be installed at the U-shaped pipe section.
外夹式流量计安装方式4
Two sensors must be installed in the horizontal direction around the pipeline and within a range of ± 45 ° of the axis horizontal position to prevent phenomena such as incomplete pipes in the upper part, bubbles, or sedimentation in the lower part from affecting the normal measurement of the sensors. If the installation location is limited by space and cannot be installed horizontally symmetrically, sensors can be installed vertically or at an angle while ensuring that there are no bubbles in the upper part of the pipe.
The selection of sensor installation points should be as far away as possible from equipment such as pumps and valves, as well as from high-power radio stations, strong magnetic field interference sources, etc;
The surface of the sensor installation point should be smooth, relatively new, and have good roundness. If there is rust or paint on the outside of the measuring tube, use a grinder or steel file to polish the surface of the measuring point to about 3 times the probe area, remove the rust and paint, and make the surface smooth and flat. Do not polish the installation point to a flat surface, and finally clean it with alcohol or gasoline.

Installation distance

The installation spacing of external sensors is based on the distance between the innermost edges of the two sensors (see installation diagram). The calculation method for spacing is to first enter the required parameters in the menu, view the number displayed in window M25, and install the sensors according to this data.


Verification of external clamp flowmeter - handheld ultrasonic flowmeter

Purpose: To verify the instantaneous flow rate, cumulative flow rate, and flow velocity of liquid in pipelines

Advantages: The flowmeter is compact and lightweight; Easy to carry; External installation; It can be installed multiple times with an accuracy of 1.0, without damaging the pipeline.

外夹式流量计校验用

For more detailed content, please refer to: Handheld ultrasonic flowmeter http://www.sh-shyb.com/show.asp?id=51


After sales and warranty

Shanghai Shihong Instrument Co., LtdAll products supplied:

Provide free telephone consultation, guidance on installation and debugging services;

Negotiate on-site guidance for installation, debugging, and other matters, and only charge reasonable travel expenses;

Large quantities can provide free on-site guidance for installation and debugging.

Service Objective:No matter how long the product is used, as long as you find us, we will solve all your problems until you are satisfied. We believe that our years of practical experience in the flowmeter industry can bring you satisfactory services.

24-Hour Hour Hotline:(Same WeChat account)