MK3Enzyme microplate reader maintenance
1. Detection mode
Absorption: Used to detect the absorbance of a sample at a specific wavelength, commonly used in experiments such as ELISA and protein quantification.
Fluorescence: Used for detecting fluorescently labeled samples, suitable for fluorescence immunoassay, fluorescence quantitative PCR, etc.
Luminescence: Used for detecting chemiluminescence or bioluminescence signals, suitable for reporting gene detection, ATP quantification, etc.
2. Wavelength range
Light absorption: typically covering the ultraviolet to visible light range, such as 200-1000 nm.
Fluorescence: The excitation wavelength and emission wavelength range are wide, depending on the configuration of the instrument.
3. Detection speed
It is usually possible to complete the reading of a 96 well plate within a few seconds, depending on the detection mode and instrument configuration.
4. Sensitivity
High sensitivity detection can detect low concentration samples, and the specific sensitivity depends on the detection mode and reagent.
5. Software functions
Built in data analysis software, supporting multiple data formats for output.
Support automatic calculation of standard curves, concentrations, OD values, etc.
User friendly interface, supporting custom experiment templates.
6. Compatibility
Compatible with standard 96 well and 384 well plates.
Supports multiple reagent kits and experimental types.
7. Other functions
Automatic calibration function ensures the accuracy of the test results.
Temperature control function (some models), supports constant temperature incubation, suitable for experiments that require temperature control.
8. Size and weight
The specific size and weight depend on the model, usually designed as a desktop for laboratory use.
9. Power Requirements
Usually 100-240V AC, 50/60Hz.
10. Communication interface
Usually equipped with a USB interface for easy connection and data transfer with a computer.
11. Application Fields
Widely used in fields such as molecular biology, immunology, cell biology, drug screening, etc.
PrecautionsMK3Enzyme microplate reader maintenance
Before use, it is necessary to select the appropriate detection mode and wavelength according to the experimental requirements.
Regularly calibrate and maintain to ensure the accuracy of test results.