Electric power oil particle size detector KT-DL432 particle counter

Performance characteristics:
Equipped with advanced optical resistance principle laser sensors from Tianjin Logan, it can detect the size and quantity of solid particles in electrical oils such as turbine oil, transformer oil, fire-resistant oil, gear oil, etc.
KT-DL432 particle counterAdopting a color LCD touch screen, it is easy to operate. Built in micro printer and capable of inputting detection reports in both Chinese and English.
The KT-DL432 particle counter is equipped with ACFTD and ISOMTD calibration methods, as well as specialized particle size detection standards for the power industry (NAS1638, SAE AS4059F).
The KT-DL432 particle counter adopts a standard RS232 interface and can be optionally equipped with powerful computer software to achieve function settings, operation control, data archiving, retrieval and analysis of the instrument, and can generate electronic reports.
The KT-DL432 particle counter is equipped with positive/negative pressure chamber devices, which can ensure the accuracy of sampling different viscosity oils and eliminate the interference of bubbles in the oil.
KT-DL432 particle counterThe accompanying air pressure pump is equipped with an oil mist separator, a micro particle separator, a moisture filter, and a molecular sieve dryer to avoid contamination of the test samples by compressed air.

Technical Specifications:
1. Light source: semiconductor laser
2. Detection range: 0.8 μ m to 600 μ m (depending on the selected sensor)
3. Particle size range: 1-100 μ m (ISO4402) or 4-70 μ m (c) (GB/T18854, ISO11171)
4. Sensitivity: 0.8 μ m (ISO4402) or 3 μ m (c) (GB/T18854, ISO11171)
5. Detection channels: 16, with particle size adjustable at intervals of 0.01 μ m
6. Sampling volume: 0.2-100ml, with an interval of 0.1ml
7. Relative error of sampling volume: better than ± 0.5%
8. Detection speed: 5-80mL/min (default 15mL/min)
9. Cleaning speed: 5-80mL/min (default 15mL/min)
10. Resolution: better than 10% (GBT18854-2002, ISO11171)
11. Overlap error limit: 12000~40000 particles/mL (depending on the selected sensor)
12. Particle count repeatability: RSD<2%
13. Relative error of particle counting: ± 5%
16. Test sample viscosity: ≤ 650cSt
17. Sample temperature for testing: 0 ℃ to 80 ℃
18. Working temperature: 0 ℃~60 ℃
19. Storage temperature: -30 ℃ to 80 ℃
20. Power supply: 100-245V, 49-62Hz
21. Dimensions: Host 430 × 320 × 590mm Pneumatic pump 330 × 266 × 255mm
21. Net weight of the instrument: 30kg for the main unit and 10kg for the air pressure pump
Electric power oil particle size detector KT-DL432 particle counter