EXTT-3CUI-24S-SB-SLE-200/500/1000 extension cable

NegotiableUpdate on 05/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

EXTT-3CUI-24S-SB-SLE-50/100/200/500/1000 RTD extension wire has high accuracy, and the American OMEGA non recycled PTFE PFA insulated thermocouple extension wire can withstand insulation from -267 to 260; #176; C, Three wire platinum resistance extension wire, in accordance with IEC color code, - SBRTD type platinum resistance extension wire, 3CUI thermocouple wire diameter 24awg wire gauge, 2 * 0.5mm (stranded wire 7-core * 0.2mm)-

Product Details

EXTT-3CUI-24S-SB-SLE-50/100/200/500/1000 RTD extension wire has high accuracy. It is a non recycled PTFE PFA insulated thermocouple extension wire from OMEGA in the United States, with insulation that can withstand temperatures ranging from -267 to 260 ° C. It is a three wire platinum resistance extension wire that complies with IEC color codes. The SBRTD platinum resistance extension wire has a 3CUI thermocouple wire diameter of 24awg and a wire gauge of 2 * 0.5mm (stranded wire with 7 cores * 0.2mm). -


Omega RTD thermistor and thermistor signal leads from the United States are available in three insulation layers: fiberglass, PFA PTFE, and polyvinyl chloride. They are available in 2-core, 3-core, and 4-core lengths, with lengths of 50, 100, 200, 500, and 1000 feet per roll


EXTT-3CUI-24S-SB-SLE-50/100/200/500/1000RTD extension cableThermocouple extension wires are soft and easy to bend, suitable for applications that require temperature measurement in narrow or curved spaces.

insulation

model

Number of cores

Core type

insulation

heat-resistant

Overall size (mm)

internal insulation

external insulation

°F

°C

Glass fiber

EXGG-2CU-20

2

solid

fiberglass

fiberglass

900

482

1.52 x 2.41

EXGG-2CU-26S

2

7 x 0.16mm

fiberglass

fiberglass

900

482

1.52 x 1.32

EXGG-3CU-26S

3

7 x 0.16mm

fiberglass

fiberglass

900

482

1.52 x 1.63

EXGG-4CU-26S

4

7 x 0.16mm

fiberglass

fiberglass

900

482

1.52 x 1.66

Neoflon®
PFA Teflon

EXTT-2CU-26S

2

7 x 0.16mm

PFA Teflon

PFA Teflon

500

260

1.07 x 1.73

EXTT-3CU-26S

3

7 x 0.16mm

PFA Teflon

PFA Teflon

500

260

1.83

EXTT-4CU-26S

4

7 x 0.16mm

PFA Teflon

PFA Teflon

500

260

2.08

PVC Polyvinyl Chloride

EXPP-2CU-24S

2

7 x 32mm

polyvinyl chloride

polyvinyl chloride

221

105

2.08 x 3.40

EXPP-3CU-24S

3

7 x 32mm

polyvinyl chloride

polyvinyl chloride

221

105

4.22



Omega's RTD thermistor products have good accuracy, reliability, and durability, and can be selected and customized according to specific needs. Whether it's industrial process control or scientific experiments, OMEGA can provide reliable temperature measurement solutions.

American OMEGA B-type thermocouple extension wire ANSI color code

EXTT-3CUI-24S-SB-SLE-50/100/200/500/1000RTD extension cableDetailed parameters:

model EXTT-3CUI-24S-SB
graduation mark RTD type
Insulation structure High quality multi-layer protection
Thermocouple alloy wire gauge AWG/diameter 3CUI thermocouple wire diameter 24awg wire gauge, 2 * 0.5mm (7-core twisted wire * 0.2mm). -
Overall external dimensions mm
value-added service We can provide OMEGA original factory certificate or send measurement on behalf of others



Wire spool length: 25 feet/roll, 50 feet/roll, 100 feet/roll, 200 feet/roll, 500 feet/roll, 1000 feet/roll, can be divided according to user requirements.


Common models:
EXTT-3CUI-24S-SB-25
EXTT-3CUI-24S-SB-50
EXTT-3CUI-24S-SB-100
EXTT-3CUI-24S-SB-200
EXTT-3CUI-24S-SB-500
EXTT-3CUI-24S-SB-1000

High precision model:
EXTT-3CUI-24S-SB-SLE-25
EXTT-3CUI-24S-SB-SLE-50
EXTT-3CUI-24S-SB-SLE-100
EXTT-3CUI-24S-SB-SLE-200
EXTT-3CUI-24S-SB-SLE-500
EXTT-3CUI-24S-SB-SLE-1000

Comparison of commonly used wire gauges:

28AWG:0.320mm, 26AWG:0.404mm, 24AWG:0.511mm, 20AWG:0.813mm, 16AWG:1.29mm,14AWG:1.63mm

EXTT-3CUI-24S-SB-SLE-50/100/200/500/1000RTD extension cableSpecification document

PDF-RTD_EXTWIRE_l_1.jpg

638328398610426703282.png

Selection of OMEGA thermocouple extension wire

The function of the thermocouple extension wire is to extend the thermoelectric electrode, which is the cold end of the moving thermocouple, and connect it with the display instrument to form a temperature measurement system. The product is mainly used in various temperature measuring devices and has been widely used in sectors such as petroleum, chemical, metallurgy, and power.

1: Generally speaking, the distance between a thermocouple and a thermometer may be several tens of meters, and the temperature at the cold end (outlet end) of the thermocouple may be different from the ambient temperature of the thermometer (even up to several tens of degrees).
If ordinary copper wires are used, according to the principle of thermocouples, there will be a temperature difference potential at the connection, which will result in measurement errors.
The problem of voltage drop in long-distance transmission wires is due to the high input impedance of the thermometer and the small transmission current caused by the temperature difference potential (millivolt level) generated by the thermocouple. The voltage drop loss on the wire is very small and generally within the error range. So there is a thermocouple transmitter that inputs thermocouple signals and outputs 4-20mA, which allows for long-distance transmission without compensating wires.


2: If an extension cable (which must match the thermocouple scale) is used, the metal material selected can generate the smallest possible temperature difference potential at the wiring point, minimizing temperature measurement errors as much as possible. That is to say, move the cold end of the thermocouple to the thermometer.

3: Precautions for laying out thermocouple extension cords near power cords

When parallel wiring thermocouple wires or compensating wires and power lines, attention must be paid to electromagnetic faults caused by power line currents. Thermocouple wires or compensating wires must use double shielding. Recommend separate strong and weak electrical wiring in cable trays


Dear customer:
Hello, our company is committed to providing high-quality products, complete solutions, and superior technical services to our customers. The main products include thermocouple connectors, Omega thermocouples, T-shaped thermocouple wires, thermocouple compensation wires, temperature patches, temperature measuring paper, and so on. You can learn more detailed information about our products through our service hotline. Our endless pursuit is to provide the best and most beautiful service. We welcome new and old customers to choose their favorite products with confidence, and we will be dedicated to serving you!