EPT-501A1Fluorescence method for dissolved oxygenon-line analysisinstrument
Measurement principle:
The dissolved oxygen analyzer uses fluorescence method to measure dissolved oxygen. The top of the sensor is covered with a layer of fluorescent substance. When the blue light emitted by the sensor shines on the fluorescent substance,Fluorescent substances emit red light when excited. Due to the quenching effect, oxygen molecules can carry away energy, so the time and intensity of the excited red light are inversely proportional to the concentration of oxygen molecules. The concentration of dissolved oxygen in water can be calculated.
maincharacteristic:
The sensor adopts a new type of oxygen sensitive membrane and comes with its ownNTCTemperature compensation function, with good repeatability and stability of measurement results;
There will be no oxygen consumption or flow rate during measurement/Stirring requirements;
Breakthrough fluorescence technology,No membrane or electrolyteBasically no maintenance is required;
Built in self diagnosis function to ensure accurate data;
Factory calibration, no calibration required for one year, can be calibrated on-site;
Digital sensors with strong anti-interference ability and long transmission distance;
Standard digital signal output, which can be integrated and networked with other devices without a controller;
The on-site installation of sensors is convenient and fast, achieving plug and play functionality.
Typical applications:
The regulating tank, biochemical tank, effluent and other process of sewage treatment plantDOOnline monitoring;
Water treatment plants, surface water, water used in various industrial production processes, aquaculture and other industriesDOOnline monitoring.
Technical parameters:
|
measuring range |
Dissolved oxygen:0-20 mg/L、0-20 ppm; Temperature:0-45℃ |
|
measurement accuracy |
Dissolved oxygen: measured value ±3%Temperature: ±0.5℃ |
|
Pressure Range |
≤0.3Mpa |
|
calibration |
Automatic air calibration, sample calibration |
|
sensor material |
fuselage:SUS316L + PVC(Normal version),SUS316LTitanium plating+ PVC(Sea water version);ORing: Fluororubber; Cable:PVC |
|
power supply |
100-240VAC (50/60HZ) |
|
output |
3road4-20mA |
|
relay |
Set up three relays, program response parameters and response values |
|
Communication protocol |
MODBUS RS485 |
|
storage temperature |
-15arrive65℃ |
|
operation temperature |
0arrive45℃ |
|
size |
Sensor: Diameter55mm*length342mm Transmitter:145*125*162mm(long*wide*tall) |
|
weight |
Sensor:1.85KG; Transmitter:1.35KG |
|
protection grade |
Sensor:IP68/NEMA6P; Transmitter:IP65/ NEMA4X |
|
Cable Length |
standard configuration10Meter cable, can be extended up to100rice |