E-mail
hongcenyibiao@163.com
-
Phone
17316309355
-
Address
No. 1000 Linxian Road, Tinglin Industrial Zone, Jinshan District, Shanghai
Shanghai Hongcen Automation Instrument Co., Ltd
hongcenyibiao@163.com
17316309355
No. 1000 Linxian Road, Tinglin Industrial Zone, Jinshan District, Shanghai
EJA430A pressure transmitterUsed to measure the pressure of gases, liquids, and vapors, and then convert it into a 4-20mADC current signal output. The Yokogawa EJA430A pressure transmitter can also communicate with each other through the BRAN controller, CENTUM CS/μ XL, or Rosemount HART 475 controller for setting and monitoring.
|
| EJA430A pressure transmitter | ||
| A membrane box | B membrane box | ||
| measurement range | -0.1~3MPa | -0.1~14MPa | |
| measurement range | 0.03~3MPa | 0.14~14MPa | |
| precision | ±0.065% | ±0.065% | |
| Protection level | IP67,NEMA 4X, And JIS C0920 immersion proof type | ||
| Explosion proof specifications | FM,CENELEC ATEX,CSA,IECEx | ||
| output signal | 4~20mA DC or FOUNDATION fieldbus or PROFIBUS PA two-wire digital communication | ||
| power supply | BRAN and HART: 10.5~42V DC (intrinsic safety type: 10.5~30V DC) | ||
| ambient temperature | -40~85℃ (-40~185℉) (普通型) | ||
| Process temperature | -40~120℃ (-40~248℉) (普通型) | ||
| Maximum Overvoltage | 4.5MPa (645psig) | 21MPa (3000psig) | |
| install | 2-inch pipe installation | ||
| Material of liquid receiving components | bellows | SUS316L (diaphragm: Hastelloy C-276), | |
| Container flange | SUS316, Hastelloy C-276, Monel | ||
| shell | Aluminum alloy or SUS316 stainless steel (optional) | ||
EJA430A - Selection Table
Basic specification code: EJA430A-DAS5A-92NN
| Item 1: Output signal | -D | 4-20mA DC/with digital communication (BRAN protocol) |
| -E | 4-20mA DC/with digital communication (HART protocol) | |
| -F | FF fieldbus communication | |
| Item 2: Measurement range (membrane box) | A | 0.03-3MPa |
| B | 0.14-14MPa | |
| Item 3: Material of liquid receiving parts | S | JIS SCS14A JIS SUS316L JIS SUS316 |
| H | JIS SCS14A 哈氏合金 C-276 JIS SUS316 | |
| M | JIS SCS14A 蒙乃尔 JIS SUS316 | |
| T | JIS SCS14A 钽 JIS SUS316 | |
| A | Hastelloy C-276 Hastelloy C-276 Hastelloy C-276 | |
| D | Hastelloy C-276 Tantalum Hastelloy C-276 | |
| B | Monel Monel Monel Monel | |
| Item 4: Process Interface | 0 | No process joint (RC1/4 internal thread on chamber flange) |
| 1 | RC1/4 internal thread process joint | |
| 2 | RC1/2 internal thread process joint | |
| 3 | 1/4NPT internal thread process joint | |
| 4 | 1/2NPT internal thread process joint | |
| 5 | No process joint (1/4NPT internal thread on chamber flange) | |
| Item 5: Material of bolts and nuts | A | JIS SCM435 3MPa 14MPa |
| B | JIS SUS630 3MPa 14MPa | |
| C | JIS SUH660 3MPa 14MPa | |
| Item 6: Installation Method | -2 | Vertical piping connection, high pressure on the right, upper installation process joint |
| -3 | Vertical piping connection, high pressure on the right, lower installation process joint | |
| -6 | Vertical piping connection, left high pressure, upper installation process joint | |
| -7 | Vertical piping connection, left high pressure, lower installation process joint | |
| -8 | Horizontal piping connection, high pressure on the right side | |
| -9 | Horizontal piping connection, high pressure on the left side | |
| Item 7: Electrical Interface | 0 | G1/2 internal thread, one electrical interface |
| 2 | 1/2NPT internal thread two electrical interfaces without blind plugs | |
| 3 | Pg13.5 internal thread two electrical interfaces without blind plugs | |
| 4 | M20 internal thread with two electrical interfaces, no blind plugs | |
| 5 | G1/2 internal thread two electrical interfaces, one blind plug | |
| 7 | 1/2NPT internal thread two electrical interfaces, one blind plug | |
| 8 | Pg13.5 internal thread two electrical interfaces, one blind plug | |
| 9 | M20 internal thread with two electrical interfaces and one blind plug | |
| Item 8: Hidden Display Table | D | digital display meter |
| E | Digital display strap measurement range setting button | |
| N | none | |
| Item 9: Installing the bracket | A | JIS SECC 2 'pipe installation (flat type) |
| B | JIS SUS304 2 'pipe installation (flat type) | |
| C | JIS SECC 2 'Pipe Installation (L-type) | |
| D | JIS SUS304 2 'Pipe Installation (L-type) | |
| N | none |