- Phone
-
Address
Room 726, Building 2, No. 55 Meisheng Road, Pudong New Area Pilot Free Trade Zone, Shanghai (Baozhou Innovation Center)
Shanghai Pumin Industrial Automation Equipment Co., Ltd
Room 726, Building 2, No. 55 Meisheng Road, Pudong New Area Pilot Free Trade Zone, Shanghai (Baozhou Innovation Center)
E+H electrode CPS11D-7BA21 in stock in Shanghai
Endress+Hauser (E+H) is a multinational corporation specializing in the production and sales of industrial automation instruments. Its products cover industrial measuring instruments such as level (liquid level), pressure, flow, analysis, temperature, systems and tank areas, recorders, and communications. It is one of the leading companies in the field of automation worldwide. E+H Company was founded in 1953 and is headquartered in Switzerland. It has over 40 branches around the world and more than 5800 employees engaged in research, development, production, sales, and maintenance work. Large scale production centers have been established in industrialized countries such as Germany, Switzerland, France, the United States, and Japan, with strict quality management and a complete quality assurance system that meets ISO9001 international standards. Connecting with the market is one of the important factors in developing high-quality and high reliability instruments. For over 40 years, E+H company has benefited greatly by closely connecting with the market, continuously developing products that are suitable for the market, and has become a comprehensive supplier.
PH electrode CPS11D-7BA21 German E+H analog or Memosens digital electrode is suitable for standard applications in the process and environmental fields with anti fouling PTFE diaphragm and optional built-in temperature sensor. It is an energy type electrode used in process and environmental engineering. Even when used in high concentration alkaline solutions or hazardous areas, reliable measurements can still be made. Adopting a low maintenance and long service life design can save electrode usage costs.
PH Digital Electrode CPS11D-7BA21 Series
SPK: CAE
[7] Type: Basic Type
[BA] Application range: 1-14PH, 0... 135 ℃, 13 bar
[2] Measuring rod length: 120mm
[1] Certification: Non explosion proof occasions
1、 Industry Application of PH Electrode CPS11D-7BA21 German E+H Digital Electrode
1. Beverages; 2. Water treatment 3, drinking water; 4. Cooling water
5. Well water; 6. Incineration plant; 7. Food industry; 8. Plastic chemical industry
9. Chemical process; 10. Pulp and paper industry; 11. Power plants, such as desulfurization equipment
12. Long term monitoring and limit value monitoring under stable process conditions
13. Can be used in hazardous areas through ATEX, FM, and CSA certification
2、 Advantages of PH electrode CPS11D-7BA21 German E+H digital electrode
1. Adopting a circular PTFE diaphragm, the electrode structure is sturdy and requires low maintenance
2. The application process pressure can reach 16 bar (232 psi)
3. Process glass can be used for measuring high concentration alkaline solutions
4. Built in Pt 100 or Pt 1000 temperature sensor with effective temperature compensation (optional)
5. Biocompatibility certification
6. Can be disinfected
7. Dual chamber system with metal leads and long toxic diffusion path, electrode - with long service life
8. Antitoxic reference ion trap (optional, only applicable to CPS11D)
3、 Advantages of PH electrode CPS11D-7BA21 digital electrode Memosens technology
1. Digital data transmission ensures data security
2. Storage of sensor characteristic parameters, easy to operate
3. Non contact induction signal transmission ensures high process safety
4. Recording sensor load parameters in the sensor enables pre maintenance
4、 PH electrode CPS11D
Technical Specifications
input
Measure variable pH value
temperature
Measurement range AA type electrode (suitable for water/sewage measurement):
pH: 1...12 pH
Temperature: -15... 80 ℃ (5... 176 F)
BA type electrode (suitable for process measurement, disinfectable):
pH:0...14 pH
Temperature: 0... 135 ℃ (32... 275 F)
Temperature: °
Be careful
Please pay attention to the operating conditions during the process.
environmental conditions
Be careful with the ambient temperature
There is a risk of frost damage
Do not use electrodes when the temperature is below -15 ℃.
Storage temperature 0... 50 ℃
Protection level IP 68: TOP68 connector, high temperature sterilization temperature can reach 135 ℃
Test conditions: 1m water column, 50 ℃, 168 hours
IP 68: Emosens connector
Test conditions: 10m water column, 25 ℃, 45 days
Process conditions
Process temperature AA type: -15... 80 ℃
BA type: 0... 135 ℃
Process pressure 0... 6 bar (0... 87 psi)/16 bar (232 psi)
(Applicable to CPS11 xBAxESA)
CPS11D-7BAxx CPS11D-7BTxx)
Conductivity min. 50 μ S/cm
Process Connection Pg 13.5
Certificates and certifications
Explosion proof certification (Ex) CPS11 (TOP68)
ATEX II 1G EEx ia IIC T3/T4/T6
FM Cl. I Div. 2, With Liquine M CM42
Use CPS11D in conjunction with Mycom S CPM153 transmitter
ATEX II 1G EEx ia IIC T3/T4/T6
FM/CSA Cl. I Div. 2, With Liquine M CM42
Used in conjunction with Mycom S CPM153 transmitter
Attention! The explosion-proof (Ex) Memosens digital electrode has an orange red ring on the connector.
TUV certified TOP68 connector
The pressure bearing capacity can reach 16 bar,
At least three times overvoltage safety protection
Memosens connector
The pressure bearing capacity can reach 16 bar,
At least three times overvoltage safety protection
Electromagnetic of CPS11D
Compatibility (EMC) interference emission and anti-interference capability
Compliant with EN 61326: 1997/A1: 1998 standards
E+H electrode CPS11D-7BA21 in stock in Shanghai

CPS11D series specific models:
CPS11D-7AA21
CPS11D-7BA21
CPS11D-7BA2G
CPS11D-7AA2G
CPS11D-7BT2G
CPS11D-7BT21