BJC CA92618 E-3055 online sewage detection pH sensor probe with circular ceramic diaphragm, resistant to pollution. Composite pH glass electrode, with an outer diameter of 12 mm, using a circular ceramic diaphragm, resistant to pollution, sealed Ag/AgCl reference electrode, dual stage reference electrode (2X), online sewage detection pH electrode using a 36 mm electrode sealed top cover, 10 foot cable, with soldered cable ends for good conductivity. Widely used in sewage detection, electroplating wastewater detection, and printing and dyeing wastewater detection.
Product Details

the United StatesBJCOnline sewage detectionpHelectrode

CA92618 E-3055 online sewage detection pH sensor probe

Features:

·compositepHGlass electrode, 12 mmouter diameter

·Using circular ceramic diaphragm, resistant to pollution, sealedAg/AgClreference electrode

·Double stage reference electrode(2X)

·the United StatesBJC E-1312Online sewage detectionpHThe electrode adopts36 mmElectrode sealing top cover, 10Foot cable,The cable ends are soldered and have good conductivity

CA92618 E-3055 online sewage detection pH sensor probe

Technical Specifications:

pHTest range:

0 - 13 pH

Applicable temperature range:

-5 to 100?C

Glass sensitive film

HT-3,Low sodium difference

Membrane impedance

100 MΩ

Zero potential

7.0 pH

reference electrode

Ag/AgCl

Reference electrolyte

3.8M KCl

Liquid bonding material

Glass and ceramics

cable

3Low noise anti-interference coarse cable

cable joint

Soldering tin head

Preservation procedures

ifpHWhen the electrode is not in use, the glass ball must be placed in a humid environment. If the glass ball dehydrates, it will temporarily affect the performance of the electrode. The recommended steps for saving are as follows:

  1. Short term: Insert the electrode into3.8 M KClIn the solution. It is strictly prohibited to store in distilled water.
  2. Long term: Fill the electrode protective cap with fresh3.8 M KClSolution, then insert the electrode. Protecting the bottleOThe ring must be sealed in place, and the bottle cap must be tightened by hand. It is strictly prohibited to store in distilled water.

Printing and dyeing wastewater detection pH electrode E-3055

Cleaning Procedure

The following three cleaning procedures are particularly effective for contaminated electrodes, almost90%The pollutants and attachments can be removed with detergent, warm water, and a soft bristled brush.

  1. washpHElectrode glass ball
    Clean with a warm neutral detergent solution. Gently brush the glass ball with a soft bristled brush, then wipe it with clean soft cotton or cloth dipped in solution. Rinse thoroughly with distilled water, then soak in saturated waterKClAt least in the solution30minute.
  2. Inorganic sediment
    Soak the glass ball of the electrode in dilute solutionHClA few minutes in the solution(Attention: Limited to the top of the glass ball only)Then clean it with distilled water and immerse it in3.8MofKClIn the solution, the time should not be less than30minute.
  3. Organic oil pollution
    Follow the steps first1Clean, if it still doesn't work, then clean the glass ball with alcohol or acetone(Attention: limited to the top of the glass ball, do not touch the diaphragm)Then immerse it3.8MofKClIn the solution, the time should not be less than30minute;

Precautions for use:

  1. Before using the new electrode, immerse it in3.8MofKCLIn the solution, the time should not be less than12Hour;
  2. Do not dry or store electrodes in distilled water;
  3. Do not directly wipe the electrode glass ball with your hands, or scrape the glass ball with a hard object;
  4. Prohibition of repeated usepHStandard solution;
  5. Cracked or broken glass electrodes cannot be used;